Ju Han

Ju Han

Auto-generated profile, based on publicly available information

Ju Han

Department of Materials Science and Engineering, Yonsei University, Seoul, Korea

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 December 2012 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Open access
HCHang Chang
Hang Chang
JHJu Hyuck Han
Ju Hyuck Han
ABAlexander Borowsky
Alexander Borowsky
LLLeandro Loss
Leandro Loss
JGJoe W. Gray
Joe W. Gray
BPBahram Parvin
Bahram Parvin
Automated analysis of whole mount tissue sections can provide insights into tumor subtypes and the underlying molecular basis of neoplasm. However, since tumor sections are collected from different laboratories, inherent technical and biological variations impede analysis for very large datasets such as The Cancer Genome Atlas (TCGA). Our objective is to characterize tumor histopathology, through the delineation of the nuclear regions, from hematoxylin and eosin (H&E ) stained tissue sections. Such a representation can then be mined for intrinsic subtypes across a large dataset for prediction and molecular association. Furthermore, nuclear segmentation is formulated within a multi-reference graph framework with geodesic constraints, which enables computation of multidimensional representations, on a cell-by-cell basis, for functional enrichment and bioinformatics analysis. Here, we present a novel method, multi-reference graph cut (MRGC), for nuclear segmentation that overcomes technical variations associated with sample preparation by incorporating prior knowledge from manually annotated reference images and local image features. The proposed approach has been validated on manually annotated samples and then applied to a dataset of 377 Glioblastoma Multiforme (GBM) whole slide images from 146 patients. For the GBM cohort, multidimensional representation of the nuclear features and their organization have identified 1) statistically significant subtypes based on several morphometric indexes, 2) whether each subtype can be predictive or not, and 3) that the molecular correlates of predictive subtypes are consistent with the literature. Data and intermediaries for a number of tumor types (GBM, low grade glial, and kidney renal clear carcinoma) are available at: http://tcga.lbl.gov for correlation with TCGA molecular data. The website also provides an interface for panning and zooming of whole mount tissue sections with/without overlaid segmentation results for quality control.

5 August 2022 in npj Flexible Electronics
Verified
Journal Article
Open access
PDF file
DKDa Bin Kim
Da Bin Kim
JHJu Han
Ju Han
SSSun Min Sung
Sun Min Sung
MKMin Seong Kim
Min Seong Kim
BCBo Kyoung Choi
Bo Kyoung Choi
YCYong Soo Cho
Yong Soo Cho
Wearable pressure sensors having versatile device structures have been extensively investigated to achieve high sensitivity under mechanical stimuli. Here, we introduce piezoelectric pressure sensors based on fabrics woven using polyvinylidene fluoride (PVDF) weft and polyethylene terephthalate (PET) warp yarns with different weave structures: 1/1 (plain), 2/2, and 3/3 weft rib patterns. The dependence of the pressure-sensing performance on the weave pattern is demonstrated with an actual large-scale fabric up to the ~2 m scale. An optimized pressure sensor with a 2/2 weft rib pattern produced a high sensitivity of 83 mV N−1, which was 245% higher than that of the 1/1 pattern. The detection performance of the optimal fabric was extensively evaluated with a variety of ambient input sources, such as pressing, bending, twisting, and crumpling, as well as various human motions. Further, a large all-fabric pressure sensor with arrayed touch pixel units demonstrated highly sensitive and stable sensing performance.

20 December 2011 in BMC Bioinformatics
Verified
Journal Article
Open access
PDF file
HCHang Chang
Hang Chang
GFGerald V Fontenay
Gerald V Fontenay
JHJu Hyuck Han
Ju Hyuck Han
GCGe Cong
Ge Cong
FBFrederick L Baehner
Frederick L Baehner
BPBahram Parvin
Bahram Parvin
Background: Our goals are to develop a computational histopathology pipeline for characterizing tumor types that are being generated by The Cancer Genome Atlas (TCGA) for genomic association. TCGA is a national collaborative program where different tumor types are being collected, and each tumor is being characterized using a variety of genome-wide platforms. Here, we have developed a tumor-centric analytical pipeline to process tissue sections stained with hematoxylin and eosin (H&E) for visualization and cell-by-cell quantitative analysis. Thus far, analysis is limited to Glioblastoma Multiforme (GBM) and kidney renal clear cell carcinoma tissue sections. The final results are being distributed for subtyping and linking the histology sections to the genomic data.Results: A computational pipeline has been designed to continuously update a local image database, with limited clinical information, from an NIH repository. Each image is partitioned into blocks, where each cell in the block is characterized through a multidimensional representation (e.g., nuclear size, cellularity). A subset of morphometric indices, representing potential underlying biological processes, can then be selected for subtyping and genomic association. Simultaneously, these subtypes can also be predictive of the outcome as a result of clinical treatments. Using the cellularity index and nuclear size, the computational pipeline has revealed five subtypes, and one subtype, corresponding to the extreme high cellularity, has shown to be a predictor of survival as a result of a more aggressive therapeutic regime. Further association of this subtype with the corresponding gene expression data has identified enrichment of (i) the immune response and AP-1 signaling pathways, and (ii) IFNG, TGFB1, PKC, Cytokine, and MAPK14 hubs.Conclusion: While subtyping is often performed with genome-wide molecular data, we have shown that it can also be applied to categorizing histology sections. Accordingly, we have identified a subtype that is a predictor of the outcome as a result of a therapeutic regime. Computed representation has become publicly available through our Web site.

1 October 2021 in Composites Part B: Engineering
Verified
Journal Article
Closed access
JHJu Han
Ju Han
JKJi Ho Kim
Ji Ho Kim
HCHong Je Choi
Hong Je Choi
SKSeung Won Kim
Seung Won Kim
SSSun Min Sung
Sun Min Sung
YCYong Soo Cho
Yong Soo Cho

1 January 2022 in European Radiology
Verified
Journal Article
Open access
PDF file
KJKwang Nam Jin
Kwang Nam Jin
EKEun Young Kim
Eun Young Kim
YKYoung Jae Kim
Young Jae Kim
GLGi Pyo Lee
Gi Pyo Lee
HKHyungjin Kim
Hyungjin Kim
YCYoung Jun Cho
Young Jun Cho
Objectives: We aim ed to evaluate a commercial artificial intelligence (AI) solution on a multicenter cohort of chest radiographs and to compare physicians' ability to detect and localize referable thoracic abnormalities with and without AI assistance. Methods: In this retrospective diagnostic cohort study, we investigated 6,006 consecutive patients who underwent both chest radiography and CT. We evaluated a commercially available AI solution intended to facilitate the detection of three chest abnormalities (nodule/masses, consolidation, and pneumothorax) against a reference standard to measure its diagnostic performance. Moreover, twelve physicians, including thoracic radiologists, board-certified radiologists, radiology residents, and pulmonologists, assessed a dataset of 230 randomly sampled chest radiographic images. The images were reviewed twice per physician, with and without AI, with a 4-week washout period. We measured the impact of AI assistance on observer's AUC, sensitivity, specificity, and the area under the alternative free-response ROC (AUAFROC). Results: In the entire set (n = 6,006), the AI solution showed average sensitivity, specificity, and AUC of 0.885, 0.723, and 0.867, respectively. In the test dataset (n = 230), the average AUC and AUAFROC across observers significantly increased with AI assistance (from 0.861 to 0.886; p = 0.003 and from 0.797 to 0.822; p = 0.003, respectively). Conclusions: The diagnostic performance of the AI solution was found to be acceptable for the images from respiratory outpatient clinics. The diagnostic performance of physicians marginally improved with the use of AI solutions. Further evaluation of AI assistance for chest radiographs using a prospective design is required to prove the efficacy of AI assistance. Key Points: • AI assistance for chest radiographs marginally improved physicians’ performance in detecting and localizing referable thoracic abnormalities on chest radiographs. • The detection or localization of referable thoracic abnormalities by pulmonologists and radiology residents improved with the use of AI assistance.

16 May 2024 in Nature Communications
Verified
Journal Article
Open access
PDF file
JHJu Han
Ju Han
SPSung Hyun Park
Sung Hyun Park
YJYe Seul Jung
Ye Seul Jung
YCYong Soo Cho
Yong Soo Cho
Most reported thin-film piezoelectric energy harvesters have been based on cantilever-type crystalline ferroelectric oxide thin films deposited on rigid substrates, which utilize vibrational input sources. Herein, we introduce flexible amorphous thin-film energy harvesters based on perovskite CaCu3Ti4O12 (CCTO) thin films on a plastic substrate for highly competitive electromechanical energy harvesting. The room-temperature sputtering of CCTO thin films enable the use of plastic substrates to secure reliable flexibility, which has not been available thus far. Surprisingly, the resultant amorphous nature of the films results in an output voltage and power density of ~38.7 V and ~2.8 × 106 μW cm−3, respectively, which break the previously reported record for typical polycrystalline ferroelectric oxide thin-film cantilevers. The origin of this excellent electromechanical energy conversion is systematically explored as being related to the localized permanent dipoles of TiO6 octahedra and lowered dielectric constant in the amorphous state, depending on the stoichiometry and defect states. This is the leading example of a high-performance flexible piezoelectric energy harvester based on perovskite oxides not requiring a complex process for transferring films onto a plastic substrate.