Shuichi Hokoi

Shuichi Hokoi

Auto-generated profile, based on publicly available information

Shuichi Hokoi

Southeast University

Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 May 2023 in Building and Environment
Verified
Journal Article
Closed access
RWRuobin Wu
Ruobin Wu
YMYan Ma
Yan Ma
HUARONG XIEHUARONG XIE
HUARONG XIE
XWXudong Wang
Xudong Wang
SHShuichi Hokoi
Shuichi Hokoi
YLYonghui Li
Yonghui Li

7 July 2023 in Heliyon
Verified
Journal Article
Open access
CXChangchang Xia
Changchang Xia
DLDiandian Liu
Diandian Liu
ZKZhenyi Kong
Zhenyi Kong
HUARONG XIEHUARONG XIE
HUARONG XIE
BMBaogang Mu
Baogang Mu
YLYonghui Li
Yonghui Li
Two tombs of the Southern Tang Dynasty (Qinling Tomb and Shunling Tomb), the most important cultural heritages in China, were built for emperors 1000 years ago and decorated with murals and stone sculptures. After their excavation in the 1950s, it was found that drastic fluctuations in the environment within the tombs had caused multiple diseases, such as salt efflorescence, powdering, and biodeterioration, which led to irreversible damage to the murals. This research comprised long-term (yearly) environmental monitoring and short-term (monthly) investigation into the distribution of salt crystallization and microbial growth within the two tombs. The objective was to unveil the relationship between the temporal and spatial distributions of the mural diseases and environmental characteristics while proposing a promising environmental regulation strategy for relic conservation. The results showed a gradual reduction in temperature fluctuation from the entrance to the back chamber and a distinct vertical stratification in relative humidity. The relative humidity in the upper areas of the tombs reached 100% during summer, while it averaged around 40–50% in the lower areas during winter. Consequently, significant condensation was observed on the ceiling in summer, whereas salt crystallization occurred on the murals in the lower space in winter. The distribution of these diseases was influenced by the airflow exchange between the interior and exterior. Furthermore, the structural disparities between the two tombs contributed to higher relative humidity and greater microorganism coverage in the Shunling Tomb compared to the Qinling Tomb. From the abovementioned findings, we suggest that microclimate control is essential for mitigating mural deterioration and should be paid more attention in the future.

8 April 2024 in Building and Environment
Verified
Journal Article
Closed access
YLYonghui Li
Yonghui Li
XHXueqing Hu
Xueqing Hu
HUARONG XIEHUARONG XIE
HUARONG XIE
RWRuobin Wu
Ruobin Wu
ZZZhengmo Zhang
Zhengmo Zhang
SHShuichi Hokoi
Shuichi Hokoi

1 January 1993 in Journal of Thermal Insulation and Building Envelopes
Verified
Journal Article
Closed access
PDF file
SHS. Hokoi
S. Hokoi
MKM.K. Kumaran
M.K. Kumaran
Glass fiber insulation is one of the most commonly used building materials in residential wall cavities. In the normal conditions under which buildings operate, the moisture content in this insulation may locally vary from that of a very dry to a fully saturated state. This gives rise to many mechanisms for moisture trans port in the insulation. This article looks at all the possible mechanisms through which moisture is transported. This is done through two series of experiments and detailed numerical analysis The experiments include investigations on water vapour transport in the presence of thermal gradients and drying of fully saturated speci mens through evaporation. Physical quantities measured include history of heat flux, boundary temperatures and relative humidities and transient moisture distributions. The simultaneous heat and moisture transport processes are mathematically described through a pair of conservation equations In a finite difference method, these equations are used for detailed numerical analysis of the processes. The numeri cal analysis makes use of the experimental data to derive consistent values for a set of moisture transport properties, representative of a sample of medium density glass fiber insulation. The properties include thermal conductivity as a function of mois turc content, vapour permeability as a function of temperature, moisture diffusivity as a function of moisture content and temperature, heat capacity and hydraulic con ductivity as functions of moisture content and sorption isotherm. A sensitivity anal ysis and an independent experiment on the drying of a randomly wet specimen sup port the results obtained from the numerical analysis

2 July 2020
Verified
Book Chapter
Closed access
PDF file
DOD. Ogura
D. Ogura
THT. Hase
T. Hase
YNY. Nakata
Y. Nakata
AMA. Mikayama
A. Mikayama
SHS. Hokoi
S. Hokoi
PXP. Xue
P. Xue

6 March 2024 in Building and Environment
Verified
Journal Article
Closed access
TZTing Zhang
Ting Zhang
CXChangchang Xia
Changchang Xia
YMYan Ma
Yan Ma
RZRuohan Zhang
Ruohan Zhang
SHShuai Han
Shuai Han
YLYonghui Li
Yonghui Li