To evaluate visual acuity, refractive outcomes, and endothelial cell density 6 months after Descemet stripping and automated endothelial keratoplasty (DSAEK). We performed an institutional review board-approved prospective study of a surgical case series of 34 patients at 2 institutions undergoing DSAEK for Fuchs endothelial dystrophy, pseudophakic bullous keratopathy, or aphakic bullous keratopathy with or without simultaneous phacoemulsification and intraocular lens implantation. Clinical outcomes, including best spectacle-corrected visual acuity (BSCVA), spherical equivalent refraction, and refractive astigmatism and topographic or keratometric astigmatism, were assessed at the 6-month postoperative examination and compared with preoperative values with paired Student t tests. The change in endothelial cell density from the eye bank examination to 6 months after transplantation was similarly evaluated. BSCVA averaged 20/99 preoperatively and 20/42 postoperatively (P < 0.0001). After DSAEK, 30 (88.2%) of 34 patients showed improved BSCVA, and 21 (61.8%) of the 34 patients achieved a BSCVA of 20/40 or better. For patients not undergoing simultaneous phacoemulsification and intraocular lens implantation, a hyperopic shift in refraction of 1.19 +/- 1.32 D was noted. Refractive astigmatism, topographic astigmatism, and keratometry showed no statistically significant change. Endothelial cell density of donor corneas averaged 2826 +/- 370 cells/mm, whereas the mean postoperative density was 1396 +/- 440 cells/mm. This finding corresponded to an average loss of 1426 cells/mm (50% loss; P = 0.0001). The first half of cases experienced an average cell loss of 1674 cells/mm (59% loss) compared with 1181 (41% loss) in the second half of cases (P = 0.005). Three (9%) of 34 grafts experienced iatrogenic graft failure and required reoperation with new donor tissue. Also, 9 (27%) of 34 grafts experienced dislocation in the early postoperative period and required repositioning. In this prospective study of DSAEK for bullous keratopathy and Fuchs endothelial corneal dystrophy, improvement of visual acuity was achieved with only a mild tendency toward hyperopic shift and without significant induced astigmatism. Endothelial cell loss was significant, however, and may be related to surgical experience.
To report the donor-to-host transmission of Candida albicans after Descemet stripping and automated endothelial keratoplasty (DSAEK). An 80-year-old woman with pseudophakic bullous keratopathy developed an infiltrate in the donor corneal lenticule after DSAEK. Donor corneoscleral rim cultures grew C. albicans. Gram stain of the removed corneal lenticule demonstrated budding yeast and pseudohyphae, and cultures yielded C. albicans. Despite topical and systemic antifungal therapy and therapeutic penetrating keratoplasty, the patient developed a blind painful eye and underwent enucleation. This case report indicates that fungal keratitis may occur from donor-to-host transmission after DSAEK. The location of the infected tissue poses diagnostic and therapeutic challenges for the surgeon.
To report a case of long-term corneal clarity after spontaneous resolution of corneal edema associated with iatrogenic endothelial trauma in a patient with Fuchs dystrophy. Retrospective case report. An 84-year-old woman with Fuchs dystrophy experienced an iatrogenic descemetorhexis during complicated phacoemulsification. Despite marked early postoperative corneal edema, she experienced spontaneous clearing of her cornea within 4 months with eventual reendothelialization of the central defect. She maintained excellent visual acuity for 16 years with no evidence of recurrent corneal edema. Self-repair of a descemetorhexis and long-term corneal clarity may occur in eyes with underlying endothelial dystrophy.
1 February 2007 in Journal of Cataract & Refractive Surgery
We describe a technique to facilitate unfolding and prevent inversion of the donor corneal lenticule during Descemet's stripping and automated endothelial keratoplasty (DSAEK). The donor corneal lenticule is unfolded in the anterior chamber using a bent 30-gauge needle on a 3 cc air syringe. The needle tip is used to pinion the edge of the lenticule while an air bubble is simultaneously injected between the folded edges of the donor graft. A gentian-violet dye mark placed on the peripheral stromal surface of the donor lenticule is used to confirm proper graft orientation. The simple technique of simultaneously fixating the donor lenticule while injecting air ensures that the graft unfolds correctly and minimizes potential mechanical trauma to the endothelium.
1 November 2008 in Eye & Contact Lens: Science & Clinical Practice
The observational case describes bilateral recurrent keratoconus in corneal transplants performed in a patient with self-induced keratoconus secondary to compulsive eye rubbing. Slitlamp findings demonstrated corneal stromal thinning and scarring in the patient's right eye and temporal corneal hydrops in his left eye. Videokeratography of the right eye confirmed the presence of corneal steepening and irregular astigmatism, consistent with the diagnosis of keratoconus involving each transplant. Together with the history of ongoing compulsive eye rubbing, these findings support the concept that chronic mechanical trauma to the cornea may contribute to the development of keratoconus.
1 July 2009 in Eye & Contact Lens: Science & Clinical Practice
With one exception, a case report of amantadine-induced corneal toxicity has described reversible corneal edema. To report a patient with unrecognized amantadine-induced corneal edema. Patient with schizophrenia and tardive dyskinesia developed bilateral corneal edema while receiving chronic amantadine hydrochloride. Both eyes underwent successful phakic Descemet's stripping automated endothelial keratoplasty, and histopathologic examination of the excised host tissue was performed. Despite initial clearing of the donor lenticules, both eyes later experienced nonimmunologic graft failure, probably related to continued amantadine corneal toxicity. After discontinuation of the amantadine, one graft demonstrated partial clearing. Histopathology demonstrated endothelial cell loss. Specular microscopy demonstrated pleomorphism and disruption of the orderly hexagonal array. Chronic amantadine hydrochloride therapy may be responsible for irreversible corneal edema and may lead to graft failure in unrecognized cases.