14 September 2023 in International Journal of Hyperthermia
To develop a computational model of microwave ablation (MWA) with a thermal accelerant gel and apply the model toward interpreting experimental observations in ex vivo bovine and in vivo porcine liver. A 3D coupled electromagnetic-heat transfer model was implemented to characterize thermal profiles within ex vivo bovine and in vivo porcine liver tissue during MWA with the HeatSYNC thermal accelerant. Measured temperature dependent dielectric and thermal properties of the HeatSYNC gel were applied within the model. Simulated extents of MWA zones and transient temperature profiles were compared against experimental measurements in ex vivo bovine liver. Model predictions of thermal profiles under in vivo conditions in porcine liver were used to analyze thermal ablations observed in prior experiments in porcine liver in vivo. Measured electrical conductivity of the HeatSYNC gel was ∼83% higher compared to liver at room temperature, with positive linear temperature dependency, indicating increased microwave absorption within HeatSYNC gel compared to tissue. In ex vivo bovine liver, model predicted ablation zone extents of (31.5 × 36) mm with the HeatSYNC, compared to (32.9 ± 2.6 × 40.2 ± 2.3) mm in experiments (volume differences 4 ± 4.1 cm3). Computational models under in vivo conditions in porcine liver suggest approximating the HeatSYNC gel spreading within liver tissue during ablations as a plausible explanation for larger ablation zones observed in prior in vivo studies. Computational models of MWA with thermal accelerants provide insight into the impact of accelerant on MWA, and with further development, could predict ablations with a variety of gel injection sites.
14 August 2018 in PLOS ONE
This paper addresses the overlearning problem in the independent component analysis (ICA) used for the removal of muscular artifacts from electroencephalographic (EEG) records. We note that for short EEG records with high number of channels the ICA fails to separate artifact-free EEG and muscular artifacts, which has been previously attributed to the phenomenon called overlearning. We address this problem by projecting an EEG record into several subspaces with a lower dimension, and perform the ICA on each subspace separately. Due to a reduced dimension of the subspaces, the overlearning is suppressed, and muscular artifacts are better separated. Once the muscular artifacts are removed, the signals in the individual subspaces are combined to provide an artifact free EEG record. We show that for short signals and high number of EEG channels our approach outperforms the currently available ICA based algorithms for muscular artifact removal. The proposed technique can efficiently suppress ICA overlearning for short signal segments of high density EEG signals.
22 September 2022 in International Journal of Hyperthermia
To assess the feasibility of delivering microwave ablation for targeted treatment of aldosterone producing adenomas using image-based computational models.We curated an anonymized dataset of diagno...
27 October 2021 in Biomedical Physics & Engineering Express
Microwave ablation is under investigation as a minimally-invasive treatment for uterine fibroids. Computational models play a vital role in the development, evaluation and characterization of candidate ablation devices. The temperature-dependent dielectric properties of fibroid tissue are essential for accurate computational modeling. Objective: To measure the broadband temperature-dependent dielectric properties of uterine fibroids excised during hysterectomy procedures. Methods : The open-ended coaxial probe method was employed for measuring the broadband dielectric properties of freshly excised human uterine fibroid samples (n = 6) obtained from an IRB-approved tissue bank. The dielectric properties (relative permittivity, ε r , and effective electrical conductivity, σ eff ) were evaluated at temperatures ranging from 23 °C–150 °C, over the frequency range of 0.5–6 GHz. Linear piecewise parametrization with respect to temperature and quadratic parametrization with respect to frequency was applied to characterize broadband temperature-dependent dielectric properties of fibroid tissue. Results : The baseline room temperature values of ε r vary from 57.5 ± 5.29 to 44.5 ± 5.77 units and σ eff changes from 0.91 ± 0.19 to 6.02 ± 0.7 S m −1 over the frequency range of 0.5–6 GHz. At temperatures close to the water vaporization point, ε r , drops considerably i.e. to 12%–14% of its baseline value for all measured frequencies. σ eff values initially rise till 98 °C and then fall to 11%–13% of their baseline values at 125 °C for frequencies ≤2.45 GHz. The σ eff follows a decreasing trend for frequencies >2.45 GHz and drops to ∼6 % of their baseline room temperature values. Conclusion: The temperature dependent dielectric properties of uterine fibroid tissues over microwave frequency range are reported for the first time in this study. Parametric models of uterine fibroid dielectric properties are also presented for incorporation within computational models of microwave ablation of fibroids.
2 December 2020 in PLOS ONE
Introduction: Acute early vascular complications are rare, but serious complications after kidney transplantation. They often result in graft loss. For this reason, shortening the diagnostic process is crucial. Currently, it is standard procedure to monitor renal graft perfusion using Doppler ultrasound (DU). With respect to acute vascular complications, the main disadvantage of this type of examination is its periodicity. It would be of great benefit if graft blood perfusion could be monitored continuously during the early postoperative period. It appears evident that a well-designed near infrared spectroscopy (NIRS) monitoring system could prove very useful during the early post-transplantation period. Its role in the immediate diagnosis of vascular complications could result in a significant increase in graft salvage, thus improving the patient’s overall quality of life and lowering morbidity and mortality for renal graft recipients. The aim of this study was to design, construct and test such a monitoring system. Materials and methods: We designed a rough NIRS-based system prototype and prepared a two-stage laboratory experiment based on a laboratory pig model. In the first stage, a total of 10 animals were used to verify and optimize the technical aspects and functionality of the prototype sensor by testing it on the animal kidneys in-vivo. As a result of these tests, a more specific prototype was designed. During the second stage, we prepared a unique laboratory model of a pig kidney autotransplantation and tested the system for long-term functionality on a group of 20 animals. Overall sensitivity and specificity were calculated, and a final prototype was prepared and completed with its own analytic software and chassis. Results: We designed and constructed a NIRS-based system for kidney graft perfusion monitoring. The measurement system provided reliable performance and 100% sensitivity when detecting acute diminished blood perfusion of the transplanted kidneys in laboratory conditions. Conclusion: The system appears to be a useful tool for diagnosing diminished blood perfusion of kidney transplants during the early postoperative period. However, further testing is still required. We believe that applying our method in current human transplantation medicine is feasible, and we are confident that our prototype is ready for human testing.