24 February 2020 in Journal of Applied Physics
Electrically fine tuning is demonstrated in a cholesteric liquid crystal (ChLC) laser based on the polymer composite system. Photo-polymerization in the mixture of LC monomer and LC hardly causes phase separation due to miscibility, forming a microscopically well-mixed polymer-LC composite structure like gel. Light scattering in the polymer-LC composite system decreases with increasing the polymer component, and the composite of equal parts of the polymer and LC exhibits high transparency in electric modulation of the selective reflection band, resulting in high-quality tuning of lasing wavelength in ChLC laser. In tuning operation, the ChLC laser retains a high slope efficiency greater than 19%, a low threshold smaller than 3 nJ/pulse, and a spectral linewidth narrower than 0.13 nm, while the change in lasing wavelength is fully continuous and reaches 13 nm.
26 September 2016 in Optics Express
We investigated the possibility of practical applications using cholesteric liquid crystals (ChLCs) with Helfrich deformation, which causes the undulation of the helical structure. Usually, the Helfrich deformation is very unstable and can be obtained only in the transient state for a short time (< 10 s) under continuous field application. Here, we found that a ChLC polymerized with spatial pattern distribution exhibited high durability of the Helfrich deformation. Furthermore, we revealed molecular alignment of the Helfrich deformation by scanning electron microscope. Finally, we fabricated a switching device embedded with color-tunable reflection pixels to exhibit potential of reflective display application.
9 February 2017 in Optics Express
We report fast electro-optic response independent of cell thickness in cholesteric liquid crystals (ChLCs). Usually, an electric field normal to the helix axis of ChLCs induces two fast and one slow response components: helical elongation (slow one), helical deformation (fast one), and flexoelectric effect (fast one). In this study, we found that a planarly aligned ChLC applied with an in-plane electric field exhibited only fast response components because the glass substrates suppressed the motion of the helical elongation. Furthermore, we demonstrated complete separation of the remaining fast components by using dielectric measurement system. Consequently, we were able to analyze dynamics of the helical deformation in detail, in which response times exhibited quadratic dependence on the helical pitch and no dependence on the cell thickness.
20 May 2015 in Applied Physics Express
7 February 2019 in Macromolecular Materials and Engineering