Earthquakes, material degradations and other environmental factors necessitate structural health monitoring (SHM). Metal foil strain gages used for SHM have low durability and low sensitivity. These factors motivated researchers to work on cement based strain sensors. In this study, the effects of temperature and moisture on electrical resistance, compressive and tensile strain gage factors (strain sensitivity) and crack sensitivity were determined for steel fiber reinforced cement based composite. A rapid increase of electrical resistance at 200 °C was observed due to damage occurring between cement paste, aggregates and steel fibers. The moisture—electrical resistance relationship was investigated. The specimens taken out of the cure were saturated with water and had a moisture content of 9.49%. The minimum electrical resistance was obtained at 9% moisture at which fiber–fiber and fiber–matrix contact was maximum and the water in micro voids was acting as an electrolyte, conducting electrons. The variation of compressive and tensile strain gage factors (strain sensitivities) and crack sensitivity were investigated by conducting compression, split tensile and notched bending tests with different moisture contents. The highest gage factor for the compression test was obtained at optimal moisture content, at which electrical resistance was minimum. The tensile strain gage factor for split tensile test and crack sensitivity increased by decreasing moisture content. The mechanisms between moisture content, electrical resistance, gage factors and crack sensitivity were elucidated. The relations of moisture content with electrical resistance, gage factors and crack sensitivities have been presented for the first time in this study for steel fiber reinforced cement based composites. The results are important for the development of self sensing cement based smart materials.
18 November 2019 in Journal of Intelligent Material Systems and Structures
Self-sensing cementitious composites can enable structures that are capable of carrying the loads applied on them while monitoring their condition. Most of earlier research has focused on the incorporation of nanofillers or microfibers into cement paste or mortar composites. However, there have been very limited number of studies on the development of steel-fiber-reinforced cementitious composites with self-sensing capabilities. This study explores strain sensitivity of concrete mixtures that include coarse aggregates up to 15 mm diameter and steel fibers with a length of 13 mm and a diameter of 0.25 mm. Five different concrete mixtures with steel fibers at 0%, 0.2%, 0.35%, 0.5%, and 0.8% volume ratios were fabricated. Compression tests with simultaneous measurement of strain and electrical resistance were conducted on the cubic specimens. Gauge factor and percent linearity that is a measure of error in strain sensing were calculated. Concrete mixtures with 0.5% steel fibers possess a strong linear relationship between applied strain and electrical resistance change with a gauge factor over 20 times larger than that of traditional metal strain gauges. Phenomenological models for different resistivity and gauge factors of cement paste/mortar with respect to concrete with large aggregates and short–long fiber cement composites were presented.