1 October 2020 in International Journal of Nanomedicine
Background: The proper topography of implant surface can induce macrophages polarization, whereas the regulation mechanism has not been fully deciphered. The study aimed to examine the regulation mechanism of macrophages M2 polarization by titanium (Ti) implant surface micro/nano topography. Results: Firstly, the titanium implant micropits-nanotubular surface with ∼ 30 nm diameters (MNT) can induce the M2 polarization of RAW264.7 spontaneously, as indicated by the spindle-like cell morphological alteration and specific molecular marker arginase-1 (Arg1) expression. Next, the autophagic vacuoles (AVs) number is significantly increased on MNT surface, as confirmed by the monodansylcadaverine (MDC) and CYTO-ID staining as well as the transmission electron microscope (TEM) observation. In addition, increasing or decreasing the autophagosomes number by rapamycin or 3-methyladenine (3-MA) will result in augmentation or attenuation of Arg1. Furthermore, blocking the fusion between autophagosomes and lysosomes by bafilomycin also significantly reduces Arg1, even in the presence of rapamycin. Finally, the ERK phosphorylation is selectively upregulated on MNT surface and the AVs number and Arg1 expression are significantly suppressed by U0126 treatment. Conclusion: Our findings suggest that the ERK-Beclin-1-autophagy axis may play a pivotal role in the regulation of M2 polarization induced by nanotopography.
18 June 2019 in Acta Metallurgica Sinica (English Letters)
The study conveys an idea to enhance the osseointegration of titanium implant (Ti) through modulating macrophages M2 polarization. The ~ 100 nm spherical mesoporous silica nanoparticles (MSN) that compromised of ~ 4-nm-diameter nano-tunnels were synthesized by the conventional “sol–gel” method, into which the dexamethasone (DEX) was loaded (DEX@MSN). The DEX@MSN could consistently release DEX and showed favorable cytocompatibility in RAW264.7 cells. The arginase-1 expression, a specific marker for macrophages M2 polarization, was also enhanced by DEX@MSN treatment. Then, the Ti was pre-treated with anodization under 5 V to generate the titania nanotubes with ~ 30 nm diameter (NT-30) and the DEX@MSN was introduced onto NT-30 surface via electrophoretic deposition, with the aid of chitosan. After optimizing the deposition parameters, the supernatants of RAW264.7 from the decorated implant surface could significantly promote the osteogenic differentiation of murine primary bone marrow mesenchymal stem cells. These findings demonstrate that delivery of DEX from implant surface can modulate the macrophages M2 polarization and result in favorable osteogenesis.