1 July 2017 in Journal of Biomedical Optics
Diffuse speckle contrast analysis (DSCA) is a noninvasive optical technique capable of monitoring deep tissue blood flow. However, a detailed study of the speckle contrast model for DSCA has yet to be presented. We deduced the theoretical relationship between speckle contrast and exposure time and further simplified it to a linear approximation model. The feasibility of this linear model was validated by the liquid phantoms which demonstrated that the slope of this linear approximation was able to rapidly determine the Brownian diffusion coefficient of the turbid media at multiple distances using multiexposure speckle imaging. Furthermore, we have theoretically quantified the influence of optical property on the measurements of the Brownian diffusion coefficient which was a consequence of the fact that the slope of this linear approximation was demonstrated to be equal to the inverse of correlation time of the speckle.
4 March 2024 in Transportation Research Part C: Emerging Technologies
20 October 2004 in Industrial & Engineering Chemistry Research
4 August 2014 in Optics Express
The slope of the inverse square of the contrast values versus camera exposure time at multi-exposure speckle imaging (MESI) can be a new indicator of flow velocity. The slope is linear as the diffuse coefficient in Brownian motion diffusion model and the mean velocity in ballistic motion model. Combining diffuse speckle contrast analysis (DSCA) and MESI, we demonstrate theoretically and experimentally that the flow velocity can be obtained from this slope. The calculation results processes of the slop don’t need tedious Newtonian iterative method and are computationally inexpensive. The new indicator can play an important role in quantitatively assessing tissue blood flow velocity.
1 April 2020 in AIP Advances
Fiber bundle endomicroscopy has potential for facilitating high-resolution (HR) in vivo imaging. One of the main challenges of this technique is the improvement of image restoration for better visualization. In this paper, we propose to reconstruct a HR image without a fixed honeycomb pattern from a noisy observation image, which can be formulated as an inverse problem. We use the obtained fixed honeycomb pattern as a prior image and use a two-step iterative shrinkage thresholding algorithm with a total variation regularization to solve this problem. In addition to the fixed honeycomb pattern removal, our method can also improve spatial resolution. The feasibility of our method is demonstrated by the images obtained from the USAF target and spider silks. In each ease, our method recovers more details than that recovered by the conventional method. The proposed theoretical framework for the removal of the honeycomb pattern in this paper shows promising and wide applications for fiber bundle imaging.
19 September 2017 in Biomedical Optics Express
Recent advancements in diffuse speckle contrast analysis (DSCA) have opened the path for noninvasive acquisition of deep tissue microvasculature blood flow. In fact, in addition to blood flow index αDB, the variations of tissue optical absorption μa, reduced scattering coefficients μꞋ s, as well as coherence factor β can modulate temporal fluctuations of speckle patterns. In this study, we use multi-distance and multi-exposure DSCA (MDME-DSCA) to simultaneously extract multiple parameters such as μa, μꞋ s, αDB, and β. The validity of MDME-DSCA has been validated by the simulated data and phantoms experiments. Moreover, as a comparison, the results also show that it is impractical to simultaneously obtain multiple parameters by multi-exposure DSCA (ME-DSCA).