David Liang Tai Wong

David Liang Tai Wong

Auto-generated profile, based on publicly available information

David Liang Tai Wong

Department of Electrical and Computer Engineering, National University of Singapore, Singapore

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 September 2019 in IEEE Sensors Journal
Verified
Journal Article
Closed access
DWDavid Liang Tai Wong
David Liang Tai Wong
JYJufeng Yu
Jufeng Yu
YLYongfu Li
Yongfu Li
CDChacko John Deepu
Chacko John Deepu
DNDuy Hoa Ngo
Duy Hoa Ngo
CHChun-Huat Heng
Chun-Huat Heng
A compact, light-weight and low-power wireless vital signs monitoring system based on Wireless Body Area Network (WBAN) protocol has been developed. The system, VySys, includes two compact wearable wireless biosensor devices for continuous vital signs capturing and transmission, a gateway to relay the message collected from the biosensors to cloud, and finally a client apps to access and display the stored data in the cloud. Both biosensor devices can last for 24 hours and weigh less than 22 g and 44 g, respectively. They consist of proprietary in-house bio-sensing integrated circuit (IC) and commercial off-the-shelf Bluetooth Low Energy (BLE) module. VySys has been deployed in clinical trials with 14 subjects. From the studies, the accuracy and advantage of VySys are evaluated and the five vital signs captured (heart rate (HR), respiration rate (RR), temperature (TMP), oxygen saturation (SpO2) and systolic blood pressure (SBP)) are benchmarked against a commercial medical-grade device. The results show strong statistical correlation (r > 0.68). In terms of clinical significance, all its mean difference are within limits of accepted clinical discrepancies. In terms of efficacy by comparing against the best known reported results, (1) VsSys is more precise by 28.2%, 36.2%, 70.0%, 37.6% and 34.4% for HR, RR, TMP, SpO2 and SBP, respectively and (2) has a narrower 95% limit of agreement (LoA) by 24.5%, 23.9%, 50.6%, 37.4% and 34.4% for HR, RR, TMP, SpO2 and SBP, respectively.

18 February 2022 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
DWDavid Liang Tai Wong
David Liang Tai Wong
YLYongfu Li
Yongfu Li
DJDeepu John
Deepu John
WHWeng Khuen Ho
Weng Khuen Ho
CHChun-Huat Heng
Chun-Huat Heng
Wearable Artificial Intelligence-of-Things (AIoT) requires edge devices to be resource and energy-efficient. In this paper, we design and implement an efficient binary convolutional neural network (bCNN) algorithm utilizing function-merging and block-reuse techniques to classify between Ventricular and non-Ventricular Ectopic Beat images. We deploy our model into a low-resource low-power field programmable gate array (FPGA) fabric. Our model achieves a classification accuracy of 97.3%, sensitivity of 91.3%, specificity of 98.1%, precision of 86.7%, and F1-score of 88.9%, along with dynamic power dissipation of only 10.5-W.

3 August 2022 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
DWDavid Liang Tai Wong
David Liang Tai Wong
YLYongfu Li
Yongfu Li
DJDeepu John
Deepu John
WHWeng Khuen Ho
Weng Khuen Ho
CHChun-Huat Heng
Chun-Huat Heng
Wearable Artificial Intelligence-of-Things (AIoT) devices exhibit the need to be resource and energy-efficient. In this paper, we introduced a quantized multilayer perceptron (qMLP) for converting ECG signals to binary image, which can be combined with binary convolutional neural network (bCNN) for classification. We deploy our model into a low-power and low-resource field programmable gate array (FPGA) fabric. The model requires 5.8× lesser multiply and accumulate (MAC) operations than known wearable CNN models. Our model also achieves a classification accuracy of 98.5%, sensitivity of 85.4%, specificity of 99.5%, precision of 93.3%, and F1- score of 89.2%, along with dynamic power dissipation of 34.9 μW.