Lennart V. Nölle

Lennart V. Nölle

Auto-generated profile, based on publicly available information

Lennart V. Nölle

Institute for Modelling and Simulation of Biomechanical Systems, University of Stuttgart, Stuttgart, Germany

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 August 2023 in Biomechanics and Modeling in Mechanobiology
Verified
Journal Article
Open access
PDF file
OMOleksandr V. Martynenko
Oleksandr V. Martynenko
FKFabian Kempter
Fabian Kempter
CKChristian Kleinbach
Christian Kleinbach
LNLennart V. Nölle
Lennart V. Nölle
PLPatrick Lerge
Patrick Lerge
JFJörg Fehr
Jörg Fehr
Nowadays, active human body models are becoming essential tools for the development of integrated occupant safety systems. However, their broad application in industry and research is limited due to the complexity of incorporated muscle controllers, the long simulation runtime, and the non-regular use of physiological motor control approaches. The purpose of this study is to address the challenges in all indicated directions by implementing a muscle controller with several physiologically inspired control strategies into an open-source extended Hill-type muscle model formulated as LS-DYNA user-defined umat41 subroutine written in the Fortran programming language. This results in increased usability, runtime performance and physiological accuracy compared to the standard muscle material existing in LS-DYNA. The proposed controller code is verified with extensive experimental data that include findings for arm muscles, the cervical spine region, and the whole body. Selected verification experiments cover three different muscle activation situations: (1) passive state, (2) open-loop and closed-loop muscle activation, and (3) reflexive behaviour. Two whole body finite element models, the 50th percentile female VIVA OpenHBM and the 50th percentile male THUMS v5, are used for simulations, complemented by the simplified arm model extracted from the 50th percentile male THUMS v3. The obtained results are evaluated additionally with the CORrelation and Analysis methodology and the mean squared error method, showing good to excellent biofidelity and sufficient agreement with the experimental data. It was shown additionally how the integrated controller allows simplified mimicking of the movements for similar musculoskeletal models using the parameters transfer method. Furthermore, the Hill-type muscle model presented in this paper shows better kinematic behaviour even in the passive case compared to the existing one in LS-DYNA due to its improved damping and elastic properties. These findings provide a solid evidence base motivating the application of the enhanced muscle material with the internal controller in future studies with Active Human Body Models under different loading conditions.

14 September 2022 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
LNLennart V. Nölle
Lennart V. Nölle
AMAtul Mishra
Atul Mishra
OMOleksandr V. Martynenko
Oleksandr V. Martynenko
SSSyn Schmitt
Syn Schmitt
Even though significant efforts in the field of injury detection with finite element active human body models (FE AHBMs) have been made, injuries of the muscle-tendon unit (MTU) have not yet been taken into consideration. Therefore, the goal of this study was to define a muscle strain injury criterion (MSIC) to evaluate the damage sustained by the musculature during muscle driven movement scenarios. The MSIC was derived from biomechanical tests found in the literature and the proposed threshold values were substantiated through a comparison to an estimate of the ultimate tensile strength of human skeletal muscle and the forces acting on the biceps femoris long head muscle during one sprinting gait cycle. The application of the MSIC to state-of-the-art FE AHBMs was demonstrated by evaluating the strain injury severity of selected neck muscles of a full-body AHBM during two seat rotation load cases. The results of the MSIC substantiation suggest that all three injury threshold values proposed in this work fall in a plausible corridor of forces acting on the MTU. The combined results of the AHBM simulations indicate that neither of the two examined seat rotations are likely to cause strain injury to the neck muscles and that the proposed MSIC can easily be applied to current AHBMs without further modification of the model architecture or the muscle parameters. The MSIC was also used to formulate a hypothesis on the aetiology of muscle strain injuries, through which it was demonstrated that material inhomogeneities in the MTU might be the cause for strain injuries sustained during otherwise physiological movements. This work is a first step in the direction of the definition of a wholistic injury criterion for the human skeletal muscle fibre.

14 December 2023 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
LNLennart V. Nölle
Lennart V. Nölle
EAEduardo Herrera Alfaro
Eduardo Herrera Alfaro
OMOleksandr V. Martynenko
Oleksandr V. Martynenko
SSSyn Schmitt
Syn Schmitt
Introduction: A common hand injury in American football, rugby and basketball is the so-called jersey finger injury (JFI), in which an eccentric overextension of the distal interphalangeal joint leads to an avulsion of the connected musculus flexor digitorum profundus (FDP) tendon. In the field of automotive safety assessment, finite element (FE) neuromuscular human body models (NHBMs) have been validated and are employed to evaluate different injury types related to car crash scenarios. The goal of this study is to show, how such a model can be modified to assess JFIs by adapting the hand of an FE-NHBM for the computational analysis of tendon strains during a generalized JFI load case.Methods: A jersey finger injury criterion (JFIC) covering the injury mechanisms of tendon straining and avulsion was defined based on biomechanical experiments found in the literature. The hand of the Total Human Model for Safety (THUMS) version 3.0 was combined with the musculature of THUMS version 5.03 to create a model with appropriate finger mobility. Muscle routing paths of FDP and musculus flexor digitorum superficialis (FDS) as well as tendon material parameters were optimized using literature data. A simplified JFI load case was simulated as the gripping of a cylindrical rod with finger flexor activation levels between 0% and 100%, which was then retracted with the velocity of a sprinting college football player to forcefully open the closed hand.Results: The optimization of the muscle routing node positions and tendon material parameters yielded good results with minimum normalized mean absolute error values of 0.79% and 7.16% respectively. Tendon avulsion injuries were detected in the middle and little finger for muscle activation levels of 80% and above, while no tendon or muscle strain injuries of any kind occurred.Discussion: The presented work outlines the steps necessary to adapt the hand model of a FE-NHBM for the assessment of JFIs using a newly defined injury criterion called the JFIC. The injury assessment results are in good agreement with documented JFI symptoms. At the same time, the need to rethink commonly asserted paradigms concerning the choice of muscle material parameters is highlighted.

14 November 2024 in PLOS ONE
Verified
Journal Article
Open access
PDF file
LNLennart V Nölle
Lennart V Nölle
IWIsabell Wochner
Isabell Wochner
MHMaria Hammer
Maria Hammer
SSSyn Schmitt
Syn Schmitt
Musculoskeletal simulations are a useful tool for improving our understanding of the human body. However, the physiological validity of predicted kinematics and forces is highly dependent upon the correct calibration of muscle parameters and the structural integrity of a model’s internal skeletal structure. In this study, we show how ill-tuned muscle parameters and unphysiological deformations of a model’s skeletal structure can be detected by using muscle elements as sensors with which modelling and parameterization inconsistencies can be identified through muscle and tendon strain injury assessment. To illustrate our approach, two modelling issues were recreated. First, a model repositioning simulation using the THUMS AM50 occupant model version 5.03 was performed to show how internal model deformations can occur during a change of model posture. Second, the muscle material parameters of the OpenSim gait2354 model were varied to illustrate how unphysiological muscle forces can arise if material parameters are inadequately calibrated. The simulations were assessed for muscle and tendon strain injuries using previously published injury criteria and a newly developed method to determine tendon strain injury threshold values. Muscle strain injuries in the left and right musculus pronator teres were detected during the model repositioning. This straining was caused by an unphysiologically large gap (12.92 mm) that had formed in the elbow joint. Similarly, muscle and tendon strain injuries were detected in the modified right-hand musculus gastrocnemius medialis of the gait2354 model where an unphysiological reduction of the tendon slack length introduced large pre-strain of the muscle-tendon unit. The results of this work show that the proposed method can quantify the internal distortion behaviour of musculoskeletal human body models and the plausibility of Hill-type muscle parameter choice via strain injury assessment. Furthermore, we highlight possible actions to avoid the presented issues and inconsistencies in literature data concerning the material characteristics of human tendons.

21 April 2024 in bioRxiv
Verified
Preprint
Open access
PDF file
LNLennart V. Nölle
Lennart V. Nölle
IWIsabell Wochner
Isabell Wochner
MHMaria Hammer
Maria Hammer
SSSyn Schmitt
Syn Schmitt
Musculoskeletal simulations are a useful tool for improving our understanding of the human body. However, the physiological validity of predicted kinematics and forces is highly dependent upon the correct calibration of muscle parameters and the structural integrity of a model’s internal skeletal structure. In this study, we show how ill-tuned muscle parameters and unphysiological deformations of a model’s skeletal structure can be detected by using muscle elements as sensors with which modelling and parameterization inconsistencies can be identified through muscle and tendon strain injury assessment. To illustrate our approach, two modelling issues were recreated. First, a model repositioning simulation using the THUMS AM50 occupant model version 5.03 was performed to show how internal model deformations can occur during a change of model posture. Second, the muscle material parameters of the OpenSim gait2354 model were varied to illustrate how unphysiological muscle forces can arise if material parameters are inadequately calibrated. The simulations were assessed for muscle and tendon strain injuries using previously published injury criteria and a newly developed method to determine tendon strain injury threshold values. Muscle strain injuries in the left and right musculus pronator teres were detected during the model repositioning. This straining was caused by an unphysiologically large gap (12.92 mm) that had formed in the elbow joint. Similarly, muscle and tendon strain injuries were detected in the modified right-hand musculus gastrocnemius medialis of the gait2354 model where an unphysiological reduction of the tendon slack length introduced large pre-strain of the muscle-tendon-unit. The results of this work show that the proposed method can quantify the internal distortion behaviour of musculoskeletal human body models and the validity of Hill-type muscle parameter choice via strain injury assessment. Furthermore, we highlight possible actions to avoid the presented issues and inconsistencies in literature data concerning the material characteristics of human tendons.

11 February 2026 in Acta Astronautica
Verified
Journal Article
Open access
PLPatrick Lerge
Patrick Lerge
LNLennart V. Nölle
Lennart V. Nölle
SSSyn Schmitt
Syn Schmitt
OMOleksandr V. Martynenko
Oleksandr V. Martynenko