Andrew McCarten Crawford

Andrew McCarten Crawford

Auto-generated profile, based on publicly available information

Andrew McCarten Crawford

Michigan State University 567 Wilson Rd.

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 January 2019 in Metallomics
Verified
Journal Article
Open access
PDF file
NDNatalia V Dolgova
Natalia V Dolgova
SNSusan Nehzati
Susan Nehzati
TMTracy C MacDonald
Tracy C MacDonald
KSKelly L Summers
Kelly L Summers
ACAndrew M Crawford
Andrew M Crawford
IPIngrid J Pickering
Ingrid J Pickering
Mercury is one of the most toxic elements threatening the biosphere, with levels steadily rising due to both natural and human activities. Selenium is an essential micronutrient, required for normal development and functioning of many organisms. While selenium is known to counteract mercury's toxicity under some conditions, to date information about the mercury-selenium relationship is fragmented and often controversial. As part of a systematic study of mercury and selenium interactions, zebrafish (Danio rerio) larvae (a model verterbrate) were exposed to methylmercury chloride or mercuric chloride. The influence of pre- and post-treatment of selenomethionine on the level and distribution of mercury and selenium in the brain and eye sections, as well as on toxicity, were examined. Selenomethionine treatment decreased the amount of maternally transfered mercury in the larval brain. Selenomethionine treatment prior to exposure to mercuric chloride increased both mercury and selenium levels in the brain but decreased their toxic effects. Conversely, methylmercury levels were not changed as a result of selenium pre-treatment, while toxicity was increased. Strikingly, both forms of mercury severely disrupted selenium metabolism, not only by depleting selenium levels due to formation of Hg–Se complexes, but also by blocking selenium transport into and out of tissues, suggesting that restoring normal selenium levels by treating the organism with selenium after mercury exposure may not be possible. Disruption of selenium metabolism by mercury may lead to disruption in function of selenoproteins. Indeed, the production of thyroid hormones by selenoprotein deiodinases was found to be severely impaired as a result of mercury exposure, with selenomethionine not always being a suitable source of selenium to restore thyroid hormone levels.

19 February 2019 in Journal of Synchrotron Radiation
Verified
Journal Article
Closed access
PDF file
ACAndrew M. Crawford
Andrew M. Crawford
ADAniruddha Deb
Aniruddha Deb
JPJames E. Penner-Hahn
James E. Penner-Hahn

8 October 2018 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
ACAndrew M. Crawford
Andrew M. Crawford
NSNicole J. Sylvain
Nicole J. Sylvain
HHHuishu Hou
Huishu Hou
MHMark Hackett
Mark Hackett
MPM. Jake Pushie
M. Jake Pushie
MKMichael E. Kelly
Michael E. Kelly
Synchrotron X-ray fluorescence imaging enables visualization and quantification of microscopic distributions of elements. This versatile technique has matured to the point where it is used in a wide range of research fields. The method can be used to quantitate the levels of different elements in the image on a pixel-by-pixel basis. Two approaches to X-ray fluorescence image analysis are commonly used, namely, (i) integrative analysis, or window binning, which simply sums the numbers of all photons detected within a specific energy region of interest; and (ii) parametric analysis, or fitting, in which emission spectra are represented by the sum of parameters representing a series of peaks and other contributing factors. This paper presents a quantitative comparison between these two methods of image analysis using X-ray fluorescence imaging of mouse brain-tissue sections; it is shown that substantial errors can result when data from overlapping emission lines are binned rather than fitted. These differences are explored using two different digital signal processing data-acquisition systems with different count-rate and emission-line resolution characteristics. Irrespective of the digital signal processing electronics, there are substantial differences in quantitation between the two approaches. Binning analyses are thus shown to contain significant errors that not only distort the data but in some cases result in complete reversal of trends between different tissue regions.

29 October 2021 in Journal of Synchrotron Radiation
Verified
Journal Article
Closed access
PDF file
ACAndrew M. Crawford
Andrew M. Crawford
BHBen Huntsman
Ben Huntsman
MWMonica Y. Weng
Monica Y. Weng
OPOlena Ponomarenko
Olena Ponomarenko
CKCheyenne D. Kiani
Cheyenne D. Kiani
IPIngrid J. Pickering
Ingrid J. Pickering

16 January 2026 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Open access
PDF file
DZDavid Z. Zee
David Z. Zee
SASoo Hyun Ahn
Soo Hyun Ahn
ACAndrew M. Crawford
Andrew M. Crawford
NSNiharika Sinha
Niharika Sinha
QJQiaoling Jin
Qiaoling Jin
TOThomas V. O’Halloran
Thomas V. O’Halloran
Analytical techniques that offer accurate, sensitive, and high-resolution elemental mapping have significantly advanced our understanding of the role of inorganic chemistry in vital biological processes.

2 July 2025 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Open access
PDF file
ACAndrew M. Crawford
Andrew M. Crawford
DZDavid Z. Zee
David Z. Zee
QJQiaoling Jin
Qiaoling Jin
ASAaron Sue
Aaron Sue
NSNiharika Sinha
Niharika Sinha
KMKeith W. MacRenaris
Keith W. MacRenaris
LA-ICP-TOF-MS provides rapid, high resolution elemental analysis of biological and non-biological samples. However, accurate real-time data analysis frequently requires the user to account for several instrumental and experimental variables that can change during data acquisition. AutoSpect is a novel software tool designed to automate the processing and fitting of LA-ICP-TOF-MS data, addressing key challenges such as time-dependent spectral drift, instrument sensitivity drift, calibration inaccuracies, and peak deconvolution, enabling researchers to rapidly and accurately process complex datasets. The tool is optimized to be robustly applicable across scientific fields (e.g., geochemistry, biology, and materials science), providing a streamlined solution for end users seeking to maximize the potential of LA-ICP-TOF-MS for high-resolution elemental mapping and isotopic analysis.