Yoojin Oh

Yoojin Oh

Auto-generated profile, based on publicly available information

Yoojin Oh

Univ. of Seoul

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 May 2024 in Water Supply
Verified
Journal Article
Open access
PDF file
HPHaeKeum Park
HaeKeum Park
YOYooJin Oh
YooJin Oh
KKKibum Kim
Kibum Kim
TKTaehyeon Kim
Taehyeon Kim
JHJinseok Hyung
Jinseok Hyung
JKJayong Koo
Jayong Koo
Water distribution networks are operated to supply tap water stably, but they suffer from leakage due to various factors, resulting in poor performance. In Korea, IoT (Internet of Things)-based smart sensors are installed to reduce these leaks, and a large amount of data is collected. In this study, to solve the data uncertainty and verification of the model's field applicability, the eXtreme Gradient Boosting (XGBoost) model, which is based on boosting, was selected. This choice was made through hyperparameter optimization using leak detection data obtained from leak detection sensors, as well as data refined through on-site leak detection. The area under the curve_receiver operating characteristic value for each leak class using the XGB model was 0.9955 for class 0, 0.9956 for class 1, and 0.9985 for class 2. In addition, the partial dependence plot of 120 Hz, which has the highest variable importance, was derived from analyzing the influence of the leak detection and classification model on the amount of leak vibration change at 120 Hz. Therefore, it is expectged the suggested methods can be used to build a GIS-based monitoring system for real-time leak detection by linking the developed model and the location of the leak detection sensor.

1 April 2026 in Water Science & Technology
Verified
Journal Article
Open access
PDF file
HPHaekeum Park
Haekeum Park
GJGyumin Jeong
Gyumin Jeong
YOYoojin Oh
Yoojin Oh
TKTaehyeon Kim
Taehyeon Kim
MKMincheol Kim
Mincheol Kim
JKJayong Koo
Jayong Koo
This graphical abstract illustrates the proposed framework for daily-scale prediction of effluent total phosphorus (T-P) and sensitivity-based optimization of coagulant dosing in a full-scale DAF system, integrating data preprocessing, machine learning, and operational decision support. Effective phosphorus control in dissolved air flotation (DAF) systems is essential for regulatory compliance in full-scale wastewater treatment plants, yet operational decisions are often constrained to daily time scales due to limited online sensing. This study proposes an interpretable, feature-engineered machine-learning framework for daily prediction of effluent total phosphorus (T-P) and sensitivity-based optimization of coagulant dosing in a full-scale municipal DAF system (410,000 m3/day). Long-term operational, water-quality, and meteorological data (1,096 days) were preprocessed using three-sigma outlier screening and multivariate imputation by chained equations (MICE). Mechanistically informed features capturing influent loading, operational conditions, short-term variability of effluent T-P (1–3 day difference-based features), and seasonal effects were incorporated. Among the evaluated models, Random Forest achieved the best performance (Test R2 = 0.818; RMSE = 0.032 mg/L), corresponding to a prediction error within 20% of the discharge limit (0.2 mg/L). SHAP analysis identified influent T-P, coagulant dosage, and short-term variation as dominant drivers across seasons. A sensitivity-based autoregressive simulation indicated that optimized dosing could reduce coagulant consumption by 32–51%, yielding an estimated annual cost saving of 1.53 billion KRW while improving effluent stability. The proposed framework demonstrates the practical value of daily-scale, interpretable machine learning for data-driven DAF operation.

2 April 2026 in Scientific Reports
Verified
Journal Article
Open access
PDF file
YOYooJin Oh
YooJin Oh
HPHaeKeum Park
HaeKeum Park
TKTaehyeon Kim
Taehyeon Kim
JKJayong Koo
Jayong Koo
Do Guen YooDo Guen Yoo
Do Guen Yoo
Water quality incidents in drinking water distribution networks require rapid operational decision-making to limit contaminant propagation and service disruption. This study proposes a hydraulically informed operational shutdown framework that integrates incident occurrence time and utility response time to support real-time decision-making during water quality emergencies. Network-based forensic analysis is applied to estimate contaminant travel times under variable demand conditions and to identify valve isolation actions that are feasible under realistic field constraints. To translate analytical results into actionable operations, the concept of Possible Operated Segments (POS) is introduced, defining the smallest isolation units that can be practically actuated during emergency response. In addition, a Cause–Impact–Duration (CID) analysis is employed to quantify location-specific impacts and the time-dependent escalation of service disruption. By jointly considering hydraulic propagation dynamics and operational feasibility, the proposed framework enables utilities to evaluate when and where intervention is most effective. Application to representative turbidity scenarios demonstrates that the framework provides clear guidance for prioritizing valve operations, containing incident impacts, and improving response timeliness, highlighting its potential as a practical decision-support tool for enhancing emergency response capability and operational resilience in drinking water distribution systems.

20 May 2024 in AQUA — Water Infrastructure, Ecosystems and Society
Verified
Journal Article
Open access
PDF file
YOYoojin Oh
Yoojin Oh
HPHaekeum Park
Haekeum Park
KKKibum Kim
Kibum Kim
TKTaehyeon Kim
Taehyeon Kim
JHJinseok Hyung
Jinseok Hyung
JKJayong Koo
Jayong Koo
Maintenance and replacement of aging water pipes are critical for urban development. To this end, trenchless rehabilitation methods that do not require excavation offer an efficient replacement for aging water pipes. Thus, this study developed a trenchless method using die drawing, which continuously inserts polyethylene (PE) liners into the reach point while maintaining traction in the host aging pipe. If the traction is removed after a certain period, the initially contracted liner pipe undergoes expansion under natural restoration and tightly adheres to the inner wall of the host pipe to achieve structural regeneration of the aging pipe. This study aimed to determine the factors influencing the die drawing process using a rehabilitation design. Accordingly, we experimented with the die drawing method to achieve structural reinforcement using high elasticity PE liners. Thereafter, based on the experimental data, we developed prediction models to estimate traction, pipe restoration rate after traction release, and pipe restoration period. The developed models estimated the minimum required restoration period and provided deeper insights into the restoration behavior of the die drawing method employed in pre-equipment maintenance before on-site construction.

1 November 2026 in Journal of Pipeline Systems Engineering and Practice
Verified
Journal Article
Closed access
TKTaehyeon Kim
Taehyeon Kim
YLYongmin Lee
Yongmin Lee
YOYoojin Oh
Yoojin Oh
HPHaekeum Park
Haekeum Park
JKJayong Koo
Jayong Koo
This study presents a quantitative framework for selecting the optimal inlet point in the design of new looped water distribution networks (WDNs). The approach integrates network topology analysis, in which betweenness centrality is computed to identify candidate inlet nodes, with a pipe diameter optimization model applied under identical objective functions and constraints. For each inlet point scenario, hydraulic reliability, expressed by the Resilience Index (RI), average water age, and design cost were evaluated. The analysis revealed that inlet points with higher betweenness centrality consistently reduced average water age, and in certain cases—such as the fourth inlet point scenario—improved RI by approximately 12% compared to the baseline. Although this configuration required a marginally higher design cost, it was determined to be the most suitable option considering long-term supply stability and operational efficiency. The proposed framework provides a practical decision-support tool for balancing hydraulic reliability and economic feasibility in the planning and design of new WDNs.

18 July 2022
Verified
Conference Paper
Open access
PDF file
YOYoojin Oh
Yoojin Oh
HPHaekeum Park
Haekeum Park
JHJinseok Hyung
Jinseok Hyung
TKTaehyeon Kim
Taehyeon Kim
KKKibum Kim
Kibum Kim
JKJayong Koo
Jayong Koo
Analysis of PDA-based Water Distribution System Suspension Risk using statistical and machine learning method