Mahmoud Shaaban

Mahmoud Shaaban

Auto-generated profile, based on publicly available information

Mahmoud Shaaban

Department of Adult Cardiology Aswan Heart Centre Aswan Egypt

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 April 2020 in The Egyptian Heart Journal
Verified
Journal Article
Open access
PDF file
MSMahmoud Shaaban
Mahmoud Shaaban
STSara Tantawy
Sara Tantawy
FEFatma Elkafrawy
Fatma Elkafrawy
DHDina Haroun
Dina Haroun
SRSoha Romeih
Soha Romeih
WEWesam Elmozy
Wesam Elmozy
Background: Tetralogy of Fallot (TOF) accounts for 10% of all CHD. It classically consists of ventricular septal defect (VSD), aortic overriding, right ventricular outflow tract (RVOT) obstruction, and RV hypertrophy. There are many anatomic variants, associated intracardiac and extracardiac anomalies that must be taken into consideration when imaging and planning the surgical procedure needed. Multi-detector computed tomography (MDCT), with its high spatial and temporal resolution, has a pivotal role in the evaluation of complex anatomical findings in both unrepaired and repaired TOF patients.Main body: Though MDCT has a limited role in the initial diagnosis of TOF, it is particularly important when there is a question about anatomy of pulmonary arteries (PAs) (whether sizable, hypoplastic, or atretic), presence of major aorto-pulmonary collaterals (MAPCAs) and presence of additional VSDs. Additionally, MDCT is crucial in the diagnosis of different anatomical variants of TOF. TOF patients with absent pulmonary valve classically have hugely dilated PAs which raise an important question about the degree and severity of airways compression. This question can be accurately answered by MDCT. TOF with double-outlet RV (DORV) has variable degrees of aortic override which can be assessed by MDCT. An atrio-ventricular septal defect (AVSD) is seen in about 13% of TOF cases and typically occurs in patients with Down syndrome. MDCT can assess the size and extent of inlet VSD and size of both ventricles (balanced or unbalanced AVSD). Coronary artery anomalies are common and important association. MDCT can identify the presence of a major coronary artery crossing the RVOT, a left anterior descending (LAD) from RCA, or a dual LAD. The clinical importance of these anomalies is its susceptibility to injury during ventriculotomy incision required for TOF repair necessitating changing the usual approach of surgery.Patients with reduced pulmonary blood flow undergo a systemic to pulmonary shunt. MDCT can assess the patency of the shunt, stenotic, or occluded segments. In surgically repaired TOF patients, MDCT can identify the sequalae and long-term complications including residual RVOT obstruction, conduit stenosis, RVOT patch aneurysm, RVH, and aortic root dilatation.Conclusion: MDCT is a safe and reliable imaging modality that provides accurate assessment of anatomical variants and associated anomalies of TOF.

20 May 2021 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Closed access
PDF file
MSMahmoud Shaaban
Mahmoud Shaaban
STSara W Tantawy
Sara W Tantawy
FEFatma Elkafrawy
Fatma Elkafrawy
SRSoha Romeih
Soha Romeih
WEWesam Elmozy
Wesam Elmozy

20 October 2023 in European Heart Journal - Case Reports
Verified
Journal Article
Open access
PDF file
HHHossameldin Hussein
Hossameldin Hussein
AEAhmed Elshall
Ahmed Elshall
AYAhmed Youssef
Ahmed Youssef
SHSoha Hekal
Soha Hekal
MSMahmoud Shaaban
Mahmoud Shaaban
Background: Intra-cavitary (IC) coronary course is a rare anatomical variant that has become more commonly reported in the last decade. While the condition is generally benign and often discovered incidentally during coronary computed tomography angiography (CCTA), these arteries are vulnerable to injury during cardiac interventions. It is unclear whether right ventricle (RV) pathology, such as dilatation or hypertrophy, plays a role in this condition. Case summary: A patient in their fifties with a medical history of rheumatic heart disease and atrial fibrillation presented with dyspnoea and orthopnea but denied any previous chest pain. Upon examination, the patient exhibited slow atrial fibrillation and generalized anasarca. Echocardiography revealed severe mitral stenosis, tricuspid regurgitation, pulmonary hypertension, and a significantly dilated and impaired RV. Before surgery, a CCTA was performed and revealed an abnormal mid-left anterior descending (LAD) course through the RV cavity with complete systolic attenuation. This finding was later confirmed through invasive angiography. Additionally, the right coronary artery (RCA) showed a mid-segment myocardial bridge (MB). The patient was scheduled for mitral and tricuspid valves’ surgery with no planned intervention to the LAD or RCA. Discussion: Coronary IC course is a rare finding that poses a risk of arterial injury during invasive cardiac procedures. It is important for all cardiac interventionists to be familiar with this diagnosis and the potential hazards during cardiac interventions. Further research is needed to determine whether RV dilatation or hypertrophy can exacerbate coronary IC course or MB.

7 September 2020 in The Egyptian Heart Journal
Verified
Journal Article
Open access
PDF file
MSMahmoud Shaaban
Mahmoud Shaaban
MSMai Salama
Mai Salama
AAAyman Alsaied
Ayman Alsaied
RERaghda Elsheikh
Raghda Elsheikh
MEMagdy Elmasry
Magdy Elmasry
Background: The most common post-surgical complication of tetralogy of Fallot (TOF) is pulmonary regurgitation (PR) which can lead to right ventricle (RV) dysfunction/failure. Cardiac magnetic resonance (CMR) is the imaging modality of choice to follow-up a repaired TOF. However, the conventional two-dimensional phase-contrast (2D-PC) flow usually underestimates PR as well as the pulmonary peak systolic velocity (PSV). Recently, four-dimensional (4D) CMR flow is introduced for more accurate quantitative flow assessment. This work aimed to compare between 4D-CMR and 2D-PC flow across the main (MPA), right (RPA), and left (LPA) pulmonary arteries (PAs) in surgically corrected TOF patients. Results: This study was conducted on 20 repaired TOF patients (range 3–9 years, 50% males). All patients had CMR exam on 1.5T scanner. 4D-CMR and 2D-PC flows were obtained at the proximal segments of the MPA, RPA, and LPA. The stroke volume index (SVI), regurgitation fraction (RF), and PSV measured by 4D-CMR were compared to 2D-PC flow. The SVI across the PAs was nearly similar between both methods (P = 0.179 for MPA, 0.218 for RPA, and 0.091 for LPA). However, the RF was significantly higher by 4D-CMR in comparison to 2D-PC flow (P = 0.027 for MPA, 0.039 for RPA, and 0.046 for LPA). The PSV as well was significantly higher by 4D-CMR flow (P = 0.003 for MPA, < 0.001 for RPA, and 0.002 for LPA). The Bland-Altman plots showed a good agreement between 4D-CMR and 2D-PC flow for the SVI, RF, and PSV across the pulmonary arteries. Conclusion: A good agreement existed between the two studied methods regarding pulmonary flow measurements. Because of its major advantage of performing a comprehensive flow assessment in a shorter time, 4D-CMR flow plays an important role in the assessment of patients with complex CHD especially in the pediatric group.

1 January 2023 in Pulmonary Circulation
Verified
Journal Article
Open access
SRSoha Romeih
Soha Romeih
FEFatma Elkafrawy
Fatma Elkafrawy
MSMahmoud Shaaban
Mahmoud Shaaban
AHAhmed Hassan
Ahmed Hassan
ISIrini Samuel
Irini Samuel
MYMagdi Yacoub
Magdi Yacoub
The purpose of this study was to validate cardiac index (CI) measured noninvasively by four‐dimensional (4D) and two‐dimensional (2D) cardiovascular magnetic resonance (CMR) flows against the invasively measured CI by right heart catheterization (RHC) in patients with pulmonary hypertension (PH). Thirty patients with PH (mean age: 32 ± 10 years) were included. 4D and 2D flow measured CI within 24 h from RHC measured CI invasively. Qualitative analysis of 4D pulmonary flow (vortex presence and eccentricity of flow) was performed.All patients had helical right‐sided flow with vortex formation; the mean vortex diameter was 29 ± 7 mm, occupying 69% of the main pulmonary artery (MPA) lumen. MPA was dilated (42 ± 9 mm). Mean CI measured by 4D flow CMR was closer to mean CI measured invasively (indirect Fick method CI = 2.1 ± 0.8 L/min/m2 vs. PA 4D flow = 2.3 ± 0.7 L/min/m2 “bias 0.22 ± 0.25 L/min, p = 0.001,” and Ao 4D flow = 2.3 ± 0.7 L/min/m2 “bias 0.2 ± 0.28 L/min, p = 0.001”), while 2D flow had a higher mean CI (PA 2D flow = 2.5 ± 0.7 L/min/m2 “bias 0.45 ± 0.7 L/min, p = 0.001” and Ao 2D flow = 2.5 ± 0.8 L/min/m2 “bias 0.45 ± 0.67 L/min, p = 0.001”). The correlation coefficients among the different comparisons of CI showed: a low correlation between the 2D flow‐indirect Fick method (Ao r2 = 0.37, PA r2 = 0.32) and a high correlation between the 4D flow‐indirect Fick method (Ao r2 = 0.86, PA r2 = 0.89).There is an excellent agreement between CI measured by 4D flow and CI measured invasively. 4D flow, a noninvasive imaging technique, could accurately measure CI better than the conventional 2D flow in patients with PH.

29 September 2023 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Closed access
MEMohamed M. Elzoghby
Mohamed M. Elzoghby
MSMai M. A. Salama
Mai M. A. Salama
MEMohamed A. Elsetiha
Mohamed A. Elsetiha
HEHanan M. El_Ahwal
Hanan M. El_Ahwal
SRSoha A. Romeih
Soha A. Romeih
WEWesam E. Elmozy
Wesam E. Elmozy