Jan Hybl

Jan Hybl

Auto-generated profile, based on publicly available information

Jan Hybl

Czech Technical University in Prague

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 December 2021 in Lékař a technika - Clinician and Technology
Verified
Journal Article
Open access
PDF file
JHJán Hýbl
Ján Hýbl
PVPetr Volf
Petr Volf
JHJan Hejda
Jan Hejda
AKAleksei Karavaev
Aleksei Karavaev
PKPatrik Kutílek
Patrik Kutílek
In this paper, we describe a technical design of wearable multi-sensor systems for physiological data measurement and wide medical applications, significantly impacted in telehealth. The monitors are composed of three analog front-end (AFE) devices, which assist with interfacing digital electronics to the noise-, time-sensitive physiological sensors for measuring ECG (heart-rate monitor), RR (respiration-rate monitor), SRL (skin resistivity monitor). These three types of sensors can be used separately or together and allow to determine a number of parameters for the assessment of mental and physical condition. The system is designed based on requirements for demanding environments even outside the realm of medical applications, and in accordance with Health and Safety at Work directives (89/391/CE and Seveso-II 96/82/EC) for occupational hygiene, medical, rehabilitation, sports and fitness applications.

28 August 2019
Verified
Book Chapter
Closed access
PDF file
PKPatrik Kutílek
Patrik Kutílek
KBKevin Bancud
Kevin Bancud
PVPetr Volf
Petr Volf
JHJan Hybl
Jan Hybl
JHJan Hejda
Jan Hejda
RDRadek Doskocil
Radek Doskocil

28 August 2019
Verified
Book Chapter
Closed access
PDF file
PKPatrik Kutílek
Patrik Kutílek
PVPetr Volf
Petr Volf
JHJan Hybl
Jan Hybl
JHJan Hejda
Jan Hejda
SVSlavka Viteckova
Slavka Viteckova
PSPavel Smrčka
Pavel Smrčka

23 May 2023
Verified
Conference Paper
Closed access
SČSlavka Čubanová
Slavka Čubanová
JHJan Hýbl
Jan Hýbl
PVPetr Volf
Petr Volf
LLLydie Leova
Lydie Leova
PKPatrik Kutílek
Patrik Kutílek
MŽMarin Žižka
Marin Žižka
From the very beginning of the use of the first so-called cold weapons, humanity has been trying to defend itself from attacks by using appropriate protective equipment. Due to the constantly deteriorating security situation in the world, the demand for these protective equipment is rising. Related to this is the development of new types of protective materials that are able to protect their user from a certain amount of kinetic energy that accompanies each cold weapon attack. In order to meet relatively strict safety and protective conditions, it is necessary to subject these materials to tests that prove their required properties and thus determine the degree of protection for which the material will be intended. These tests should be simple, easy to perform and repeatable, and at the same time they must have a sufficiently high indicative value about the quality of the tested material. For these tests, it is necessary to use special test systems. Most of the systems in use are currently manually controlled and testing is time-consuming. The article describes a new semi-automatic system, which is based on a mechatronic construction, which enables more precise and faster testing of materials. We focus on individual tests of system parameters and constructions of individual parts. The results of tests of part of the system are described and the arrangement of systems for use in practice is recommended.