Rui Lyu

Rui Lyu

Auto-generated profile, based on publicly available information

Rui Lyu

Beijing University of Posts and Telecommunications, Beijing, China

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 August 2024 in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
Verified
Journal Article
Open access
LZLangcheng Zhao
Langcheng Zhao
RLRui Lyu
Rui Lyu
HLHang Lei
Hang Lei
QLQi Lin
Qi Lin
AZAnfu Zhou
Anfu Zhou
ZYZheng Yang
Zheng Yang
The electrocardiogram (ECG) has always served as a crucial biomedical examination for cardiac diseases monitoring and diagnosing. Typical ECG measurement requires attaching electrodes to the body, which is inconvenient for long-term monitoring. Recent wireless sensing maps wireless signals reflected from human chest into electrical activities of heart so as to reconstruct ECG contactlessly. While making great progress, we find existing works are effective only for healthy populations with normal ECG, but fall short when confronted with the most desired usage scenario: reconstructing ECG accurately for people with cardiac diseases such as atrial fibrillation, premature ventricular beat. To bridge the gap, we propose AirECG, which moves forward to reconstruct ECG for both healthy people and even cardiac patients with morbid ECG, i.e., irregular rhythm and anomalous ECG waveform, via contactless millimeter-wave sensing. To realize AirECG, we first custom-design a cross-domain diffusion model that can perform multiple iteration denoising inference, in contrast with the single-step generative models widely used in previous works. In this way, AirECG is able to identify and eliminate the distortion due to the unstable and irregular cardiac activities, so as to synthesize ECG even during abnormal beats. Furthermore, we enhance the determinacy of AirECG, i.e., to generate high-fidelity ECG, by designing a calibration guidance mechanism to combat the inherent randomness issue of the probabilistic diffusion model. Empirical evaluation demonstrates AirECG's ability of ECG synthesis with Pearson correlation coefficient (PCC) of 0.955 for normal beats. Especially for abnormal beats, the PCC still exhibits a strong correlation of 0.860, with 15.0%~21.1% improvement compared with state-of-the-art approaches.

6 March 2024 in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
Verified
Journal Article
Open access
LZLangcheng Zhao
Langcheng Zhao
RLRui Lyu
Rui Lyu
QLQi Lin
Qi Lin
AZAnfu Zhou
Anfu Zhou
HZHuanhuan Zhang
Huanhuan Zhang
YTYi-da Tang
Yi-da Tang
Arrhythmia is a common problem of irregular heartbeats, which may lead to serious complications such as stroke and even mortality. Due to the paroxysmal nature of arrhythmia, its long-term monitoring and early detection in daily household scenarios, instead of depending on ECG examination only available during clinical visits, are of critical importance. While ambulatory ECG Holter and wearables like smartwatches have been used, they are still inconvenient and interfere with users' daily activities. In this paper, we bridge the gap by proposing mmArrhythmia, which employs low-cost mmWave radar to passively sense cardiac motions and detect arrhythmia, in an unobtrusive contact-less way. Different from previous mmWave cardiac sensing works focusing on healthy people, mmArrhythmia needs to distinguish the minute and transient abnormal cardiac activities of arrhythmia patients. To overcome the challenge, we custom-design an encoder-decoder model that can perform arrhythmia feature encoding, sampling and fusion over raw IQ sensing data directly, so as to discriminate normal heartbeat and arrhythmia. Furthermore, we enhance the robustness of mmArrhythmia by designing multichannel ensemble learning to solve the model bias problem caused by unbalanced arrhythmia data distribution. Empirical evaluation over 79,910 heartbeats demonstrates mmArrhythmia's ability of robust arrhythmia detection, with 97.32% accuracy, 98.63% specificity, and 92.30% sensitivity.

4 November 2024
Verified
Conference Paper
Open access
ZZZixin Zheng
Zixin Zheng
YLYumeng Liang
Yumeng Liang
RLRui Lyu
Rui Lyu
JBJunjie Bao
Junjie Bao
YHYiwen Huang
Yiwen Huang
QZQian Zhang
Qian Zhang
Cuff-less methods, especially pulse wave analysis (PWA) techniques with PPG/mmWave sensing, have shown great potential for non-intrusive blood pressure (BP) monitoring. However, the state-of-the-art solutions are only validated on small-scale healthy subjects, neglecting patients with abnormal BP and thus a more urgent need for BP monitoring. To bridge the gap, we first build the largest mmWave-BP dataset to our knowledge, including 930 real patients with cardiovascular diseases, and perform extensive experiments, which reveals that all existing PWA methods exhibit far less satisfactory performance with standard deviation errors (STD) exceeding 16 mmHg for systolic BP (SBP) and 11mmHg for diastolic BP (DBP). An in-depth investigation shows that physiological factors have complex effect on vascular elasticity and structure, thus people with very different BP values may exhibit extremely similar pulse waveform, which leads to confusion in model learning. In this work, we propose BP3, which fuses physiological factors into sensing-data-driven deep-learning framework, so as to capture the intricate effect of physiological factors during the whole process of learning pulse waveforms. Evaluation results show that BP3 achieves the mean errors of-1.57 mmHg and -0.34 mmHg, STD of 9.77 mmHg and 7.93 mmHg for SBP and DBP, respectively. Moreover importantly, BP3 shows remarkable gain particularly for subjects with abnormal BP, achieving mean errors that are only 0.48% ~ 20.86% of the state-of-the-art solutions.

26 May 2025 in IEEE Internet of Things Journal
Verified
Journal Article
Closed access
LZLangcheng Zhao
Langcheng Zhao
RLRui Lyu
Rui Lyu
AZAnfu Zhou
Anfu Zhou
QGQi Guo
Qi Guo
HMHuadong Ma
Huadong Ma
Heart rate variability (HRV) is an essential indicator of cardiovascular and nervous system function, with wide applications in health monitoring and disease management. Traditional contact-based methods like electrocardiograms (ECG) and photoplethysmography (PPG), while effective, face significant limitations in user experience, such as discomfort during prolonged use, and challenges in long-term, continuous monitoring. Meanwhile, contactless wireless sensing based on millimeter wave (mmWave) radar offers a promising alternative but is hindered by issues of directional sensing and noise interference. In this article, we propose mmWave Cardiac Gram (mmCG), a contactless HRV monitoring system. Specifically, it integrates a heartbeat spatial localization method for directional sensing, which significantly improves the SNR, and a dynamic peak search algorithm that leverages heartbeat temporal correlations to effectively mitigate the impact of artifacts. Experimental results show that mmCG achieves advanced performance, reducing the IBI error to 9.44 ms, a 51.29% improvement over existing methods. With its lightweight design and enhanced accuracy, mmCG offers a practical solution for daily HRV monitoring, with potential applications in stress management, personalized healthcare, and cardiovascular disease monitoring.

3 September 2025 in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
Verified
Journal Article
Open access
RLRui Lyu
Rui Lyu
HLHang Lei
Hang Lei
LZLangcheng Zhao
Langcheng Zhao
AZAnfu Zhou
Anfu Zhou
HMHuadong Ma
Huadong Ma
Olfaction, an essential human sense, has drawn significant attention for its sensitivity and environmental awareness, driving advancements in digital olfaction technologies. So far, the most widely used device in digital olfaction is the electronic nose, but direct contact with samples limits it applicability for widespread usage. In this paper, we bridge the gap by proposing Digital Olfactory Mucosa (DOM), which utilizes terahertz signals for contactless sensing and classifying odorant molecules by exploiting the molecular absorption properties of terahertz. Unlike recent wireless gas detecting works that focus on major molecules in the air, DOM specifically focuses on the rare odorant molecules in the air, usually less than 1ppm. To meet the challenge, we custom-design a unique signal processing model based on a hybrid neural network that can perform odorant feature sampling and fusion over time-domain and frequency-domain signals, so as to extract rare odorant molecular features. Furthermore, in order to better accommodate the diversity of odors, we design a dual granularity contrastive learning schema to optimize the spatial distribution of extracted olfactory features, which enhances the scalability of DOM. Evaluation on 25 odorant molecules within 10 odor clusters demonstrates DOM's ability to detect and classify odors, with 98.71% accuracy in odor cluster classification, and 98.66% in specific odor classification.

30 September 2026 in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies
Verified
Journal Article
Open access
RLRui Lyu
Rui Lyu
HFHao Feng
Hao Feng
AZAnfu Zhou
Anfu Zhou
HMHuadong Ma
Huadong Ma
DLDa Liu
Da Liu
CSChunli Shao
Chunli Shao
Arrhythmia poses a severe health risk, necessitating long-term monitoring to prevent complications like stroke. However, existing radar monitoring solutions fail to detect concurrent arrhythmias and lack clinical interpretability. In this paper, we bridge the gap by proposing READ (Radar Evidence-based Arrhythmia Diagnosis). Unlike previous “black-box” approaches, READ integrates mmWave radar with Large Language Models (LLMs) to deliver transparent, evidence-based diagnoses. However, training such a reasoning-capable model is hindered by the scarcity of mmWave datasets with detailed diagnostic annotations. To tackle this challenge, we first pretrain on large-scale ECG data to learn robust physiological patterns and then transfer this knowledge to radar domain using our proposed Cross-Physics Knowledge Distillation (CPKD) framework. Furthermore, we design a Morphological Grouping Tokenizer and a Morphology-Anchored Clinical Reasoning module, which parse raw signals into semantic tokens to guide step-by-step diagnostic inference. Empirical evaluation on a real-world dataset of 205 patients, collected in collaboration with medical institutions, demonstrates READ 's superior performance, achieving a 90.12% exact match ratio and a 0.9625 F 1 score. Our framework significantly outperforms state-of-the-art baselines while providing interpretable clinical reports.