Toshitaka Ishiguro

Toshitaka Ishiguro

Auto-generated profile, based on publicly available information

Toshitaka Ishiguro

Department of Radiology, Institute of Medicine, University of Tsukuba, Tsukuba, Ibaraki, Japan

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 November 2016 in Polish Journal of Radiology
Verified
Journal Article
Open access
PDF file
HTHiroaki Takahashi
Hiroaki Takahashi
KNKatsuhiro Nasu
Katsuhiro Nasu
MMManabu Minami
Manabu Minami
TKTakahiro Kojima
Takahiro Kojima
HNHiroyuki Nishiyama
Hiroyuki Nishiyama
TKTakahiro Konishi
Takahiro Konishi
BACKGROUND:To evaluate organ atrophy induced by sorafenib and sunitinib, we retrospectively reviewed the CT scans of renal cell carcinoma (RCC) patients receiving molecular targeted therapy (MTT) using sorafenib or sunitinib, and performed volumetric...

1 January 2025 in Magnetic Resonance in Medical Sciences
Verified
Journal Article
Open access
PDF file
TSTsukasa Saida
Tsukasa Saida
WGwenchao gu
wenchao gu
SHSodai Hoshiai
Sodai Hoshiai
TIToshitaka Ishiguro
Toshitaka Ishiguro
MSMasafumi Sakai
Masafumi Sakai
TAKAHITO NAKAJIMATAKAHITO NAKAJIMA
TAKAHITO NAKAJIMA
This review explores the significant progress and applications of artificial intelligence (AI) in obstetrics and gynecological MRI, charting its development from foundational algorithmic techniques to deep learning strategies and advanced radiomics. This review features research published over the last few years that has used AI with MRI to identify specific conditions such as uterine leiomyosarcoma, endometrial cancer, cervical cancer, ovarian tumors, and placenta accreta. In addition, it covers studies on the application of AI for segmentation and quality improvement in obstetrics and gynecology MRI. The review also outlines the existing challenges and envisions future directions for AI research in this domain. The growing accessibility of extensive datasets across various institutions and the application of multiparametric MRI are significantly enhancing the accuracy and adaptability of AI. This progress has the potential to enable more accurate and efficient diagnosis, offering opportunities for personalized medicine in the field of obstetrics and gynecology.

1 January 2025 in Magnetic Resonance in Medical Sciences
Verified
Journal Article
Open access
PDF file
TSTsukasa Saida
Tsukasa Saida
MYMiki Yoshida
Miki Yoshida
TIToshitaka Ishiguro
Toshitaka Ishiguro
SHSodai Hoshiai
Sodai Hoshiai
MSMasafumi Sakai
Masafumi Sakai
TAKAHITO NAKAJIMATAKAHITO NAKAJIMA
TAKAHITO NAKAJIMA
Purpose: This study aimed to compare MRI findings among benign, borderline, and malignant ovarian seromucinous neoplasms.Methods: We retrospectively analyzed MRI data from 24 patients with ovarian seromucinous neoplasms—seven benign, thirteen borderline, and six malignant. The parameters evaluated included age, tumour size, morphology, number, height, apparent diffusion coefficient (ADC) values, T2 ratios, time-intensity curve (TIC) descriptors, and TIC patterns of the mural nodules. Additionally, we examined the T2 and T1 ratios of the cyst contents, tumour markers, and the presence of endometriosis. We used statistical tests, including the Kruskal–Wallis and Fisher–Freeman–Halton exact tests, to compare these parameters among the three aforementioned groups.Results: The cases showed papillary architecture with internal branching in 57% of benign, 92% of borderline, and 17% of malignant cases. Three or fewer mural nodules were seen in 57% of benign, 8% of borderline, and 17% of malignant cases. Compared to benign and borderline tumours, mural nodules of malignant neoplasms had significantly increased height (P = 0.015 and 0.011, respectively), lower means ADC values (P = 0.003 and 0.035, respectively). The mural nodules in malignant cases also demonstrated significantly lower T2 ratios than those in the benign cases (P = 0.045). Most neoplasms displayed an intermediate-risk TIC pattern, including 80% benign, 83% borderline, and 60% malignant neoplasms, and no significant differences were observed.Conclusion: Most benign and borderline tumours exhibited a papillary architecture with an internal branching pattern, whereas this feature was less common in malignant neoplasms. Additionally, benign tumours had fewer mural nodules compared to borderline tumours. Malignant neoplasms were characterized by mural nodules with increased height and lower ADC values than those in benign and borderline tumours. Interestingly, all three groups predominantly exhibited an intermediate-risk TIC pattern, emphasizing the complexity of diagnosing seromucinous neoplasms using MRI.

12 July 2024 in Indian Journal of Radiology and Imaging
Verified
Journal Article
Open access
PDF file
SSSaki Shibuki
Saki Shibuki
TSTsukasa Saida
Tsukasa Saida
KMKensaku Mori
Kensaku Mori
TIToshitaka Ishiguro
Toshitaka Ishiguro
TATaishi Amano
Taishi Amano
TAKAHITO NAKAJIMATAKAHITO NAKAJIMA
TAKAHITO NAKAJIMA
Objective This article evaluates the ability of low-energy (40 keV) virtual monoenergetic images (VMIs) in the local diagnosis of cervical cancer compared with that of conventional computed tomography (C-CT) and magnetic resonance imaging (MRI), using clinicopathologic staging as a reference. Methods This prospective study included 33 patients with pathologically confirmed cervical cancer who underwent dual-energy CT and MRI between 2021 and 2022. The contrast-to-noise ratio (CNR) of the tumor-to-myometrium was compared between C-CT and VMI. Additionally, sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) for each local diagnostic parameter were compared between C-CT, VMI, and MRI. Interradiologist agreement was also assessed. Results The mean CNR was significantly higher on VMI (p = 0.002). No significant difference in AUC was found between C-CT and VMI for all local diagnostic parameters, and the specificity of VMI was often significantly less than that of MRI. For parametrial invasion, mean sensitivity, specificity, and AUC for C-CT, VMI, and MRI were 0.81, 0.99, 0.93; 0.64, 0.35, 0.79; and 0.73, 0.67, 0.86, respectively, and MRI had significantly higher specificity and AUC than that of VMI (p = 0.013 and 0.008, respectively). Interradiologist agreement was higher for VMI than C-CT and for MRI than VMI. Conclusion The CNR of VMI was significantly higher than C-CT and interradiologist agreement was better than with C-CT; however, the overall diagnostic performance of VMI did not significantly differ from C-CT and was inferior to MRI. VMI was characterized by low specificity, which should be understood and used for reading.

1 January 2026 in Magnetic Resonance in Medical Sciences
Verified
Journal Article
Open access
PDF file
TSTsukasa Saida
Tsukasa Saida
ASAyumi Shikama
Ayumi Shikama
MYMiki Yoshida
Miki Yoshida
TATaishi Amano
Taishi Amano
TIToshitaka Ishiguro
Toshitaka Ishiguro
TAKAHITO NAKAJIMATAKAHITO NAKAJIMA
TAKAHITO NAKAJIMA
Purpose: MRI findings of high-grade serous carcinoma (HGSC) with and without homologous recombinationdeficiency (HRD) were compared to explore the feasibility of using MRI as a genetic predictor. Methods: We retrospectively reviewed MRI data from HRD-positive and HRD-negative HGSC andevaluated tumor size, appearance, apparent diffusion coefficient (ADC), time-intensity curve, and severaldynamic contrast-enhanced curve descriptors. Age, primary site, tumor stage, bilaterality, presence oflymph node metastasis, presence of peritoneal metastasis, and tumor marker levels were also compared. Results: Forty-eight patients with HRD-positive HGSC (17 patients with BRCA1 variant, 9 patients withBRCA2 variant, and 22 without BRCA variants) and 18 patients with HRD-negative HGSC were included.The HRD-negative patients’ mean age was 67 years, which was significantly higher than that of the HRDpositivepatients (60 years, P = 0.011). High-risk time-intensity curve (TIC) patterns were more common inHRD-negative tumors (94%) than in HRD-positive tumors (63%; P = 0.047). Tumors without HRDexhibited significantly higher wash-in rates (P = 0.023). Additionally, unresectable lymph node metastaseswere significantly more frequent in HRD-negative patients (P = 0.013). No significant differences wereobserved in the other evaluated factors. Conclusion: The comparison between HGSC with and without HRD revealed that HGSC without HRD was significantly associated with older age, a higher likelihood of exhibiting a high-risk TIC pattern, ahigher wash-in rate, and a higher frequency of unresectable lymph node metastasis.

1 January 2025 in Magnetic Resonance in Medical Sciences
Verified
Journal Article
Open access
PDF file
MYMiki Yoshida
Miki Yoshida
TSTsukasa Saida
Tsukasa Saida
SSSaki Shibuki
Saki Shibuki
TIToshitaka Ishiguro
Toshitaka Ishiguro
MSMasafumi Sakai
Masafumi Sakai
TAKAHITO NAKAJIMATAKAHITO NAKAJIMA
TAKAHITO NAKAJIMA
Purpose: To assess the utility of apparent diffusion coefficient maps (ADC) for diagnosing myometrial invasion (MI) in endometrial cancer (EC).Methods: This retrospective study included 164 patients (mean age, 56 years; range, 25–89 years) who underwent preoperative MRI for EC with <1/2 MI or no MI between April 2016 and July 2023. Five sequences were evaluated: T2-weighted imaging (T2WI), diffusion-weighted imaging (DWI), ADC, dynamic contrast-enhanced T1-weighted imaging (DCE-T1WI), and contrast-enhanced T1WI (CE-T1WI). Three experienced radiologists independently assessed the sequences for MI. For ADC, MI was determined if the endometrial-myometrial junction-tumor boundary had disappeared. Additionally, the assessment of MI was performed using the combination of T2WI, DWI, and ADC, as well as T2WI, DCE-T1WI, and CE-T1WI. The sensitivity, specificity, accuracy, and area under the receiver operating characteristic curve (AUC) for the presence of MI were calculated and compared between the sequences and combinations. Inter-reader agreement was assessed using kappa (κ) statistics.Results: The sensitivity of ADC was significantly higher than T2WI (P < 0.001) and DCE-T1WI (P = 0.018) for one reader and significantly higher than CE-T1WI (P = 0.045 and 0.043) for two readers. The specificity of ADC was significantly lower than T2WI (P = 0.015 and < 0.001) and CE-T1WI (P = 0.031 and 0.01) for two readers and significantly lower than DCE-T1WI (P = 0.031) for one reader. The AUC of ADC was significantly higher than T2WI (P = 0.048) and DCE-T1WI (P = 0.049) for one reader. The combination including ADC showed higher positive predictive value for all three readers compared to any sequence or combination including contrast enhancement. Additionally, ADC demonstrated the highest agreement rates.Conclusion: ADC had high sensitivity for MI and the highest agreement rate among all sequences. Thus, this sequence, combined with other sequences, can be crucial for a comprehensive evaluation of MI.