Objective: To evaluate the effect of the placement angle, diameter, length and bone density on the mechanical stability of orthodontic mini-implants by measuring their pull-out strengths. Design: A total of 120 mini-implants of four different dimensions made from titanium were used. They measured 1.3 × 6.0mm, 1.3 × 8.0 mm, 1.5 × 6.0 mm and 1.5 × 8.0 mm. Synthetic polyurethane bone blocks (Saw Bones, USA) in two different densities were used. Setting: Each size of mini-implant was inserted equidistantly into synthetic bone blocks of two different densities, in three different insertion angles of 30°, 60° and 90°. This resulted in 24 test groups with five mini-implants allocated to each group. Methods: The pull-out strength was measured using an Instron Universal Testing Machine exerting a vertical force parallel to the long axis of the mini-implant until removal or failure occurred. Peak load at failure of the mini-implant was recorded in kN. Results: Showed that mini-implants placed at an insertion angle of 30° offered least resistance to pull-out. Mini-implants 6.0 mm in length showed less pull-out strength compared to the longer 8.0-mm mini-implants. Mini-implants 1.3 mm in diameter provided similar pull-out values as 1.5-mm mini-implants. Bone densities of 0.20 g/cc and 0.32 g/cc did not affect the pull-out strength of mini-implants. Conclusion: From the study, it was concluded that a logical choice of mini-implant dimension and prudent use of placement technique can help achieve the treatment goals with a reduced hazard of mini-implant failure.
17 July 2023 in Journal of Dental Research, Dental Clinics, Dental Prospects
Background. This study assessed the stability of the outcomes after mandibular incisor extraction (MIE) using intercanine width and peer assessment rating (PAR) scores in orthodontic patients. Methods. PubMed, Cochrane Library, Science Direct, Google Scholar, Ovid, and SciELO were systematically searched without restrictions until August 2022. A risk of bias assessment was performed using Newcastle-Ottawa Scale (NOS). The Grading of Recommendations, Assessment, Development, and Evaluation tool was used to assess the quality of evidence. Random effects meta-analysis was performed using RevMan software. Results. Seven retrospective studies met the inclusion criteria and were included. Meta-analysis identified a statistically significant reduction in intercanine width with MIE after the retention period. The mean difference in post-retention changes concerning intercanine width (MD=0.14, 95% CI: -2.17–1.89; P<0.00001) was significantly higher in premolar extraction (PE) compared to incisor extraction and significantly less in non-extraction compared to incisor extraction (MD=0.72, 95% CI: -0.59–2.03; P70%) with MIE treatment, with no significant difference in the reduction percentage compared to premolar and non-extraction groups. Conclusion. With the existing retrospective studies of limited evidence, treatment outcomes with MIE were found to show good improvements in PAR scores. Some reduction in the intercanine width was evident after the retention period, which was observed even with the other two treatment modalities that were compared. Hence, with careful evaluation, MIE could be considered a valid treatment option.