Huanbo Feng

Huanbo Feng

Auto-generated profile, based on publicly available information

Huanbo Feng

Guangxi Key Laboratory for Relativistic Astrophysics, School of Physical Science and Technology, Guangxi University, 100 Daxue East Road, Nanning, China

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 April 2024 in Nuclear Science and Techniques
Verified
Journal Article
Closed access
PDF file
HFHuan-Bo Feng
Huan-Bo Feng
HLHong-Bang Liu
Hong-Bang Liu
DWDong Wang
Dong Wang
ZLZi-Li Li
Zi-Li Li
SLShu-Lin Liu
Shu-Lin Liu
ELEn-Wei Liang
En-Wei Liang

1 April 2024 in Journal of Instrumentation
Verified
Journal Article
Closed access
HFHuan-Bo Feng
Huan-Bo Feng
HLHong-Bang Liu
Hong-Bang Liu
DWDong Wang
Dong Wang
SLShu-Lin Liu
Shu-Lin Liu
QLQian Liu
Qian Liu
ELEn-Wei Liang
En-Wei Liang
The Gas Microchannel plate Pixel Detector (GMPD) is purposefully designed and manufactured for astrophysical X-ray polarization detection, slated for use in various space missions such as the Cosmic X-ray Polarization Detector (CXPD) CubeSat, Low Energy Polarimeter Detector (LPD/POLAR-2), and the Chasing All Transients Constellation Hunters (CATCH). Past research has explored the polarization and spectral performance of GMPD. This study, for the first time, experimentally investigates its imaging characteristics to validate its imaging capabilities. Utilizing a deconvolution method, we measured the position resolution of GMPD, revealing distinctions in the detector's imaging capabilities for X-rays of varying energies and in orthogonal directions. These research findings will provide targeted insights for optimizing the photoelectron track reconstruction algorithm and correcting systematic effects in polarization measurements for future applications of GMPD.

1 May 2025 in Journal of Instrumentation
Verified
Journal Article
Closed access
FJFan Jiang
Fan Jiang
HLHongbang Liu
Hongbang Liu
XLXiwen Liu
Xiwen Liu
CDCong Dai
Cong Dai
YYYan Yang
Yan Yang
ELEnwei Liang
Enwei Liang
At the High Energy cosmic-Radiation Detection (HERD) facility, the transition radiation detector (TRD) detects transition radiation (TR) signals, enabling the in-orbit calibration of the calorimeter (CALO). This paper presents an optimized TRD prototype with an innovative compartmentalized gas chamber structure, in which a polyimide membrane separates the radiator and detector gas regions. This design allows the radiator and detector to operate with independent working gases within a single chamber, thereby increasing the detection efficiency of TR photons. Furthermore, the detector's working gas composition was optimized according to the compartmentalized gas chamber design. Using a Xe/CH4 gas mixture, the detector achieves a gas gain of 3 × 104 and an optimal energy resolution of 20.6% (FWHM at 5.9 keV). Beam tests results confirmed the performance enhancement achieved by introducing the compartmentalized gas chamber and Xenon, with the average number of detected TR photons per event increasing from 0.44 to 0.72 at electron momentum of 3 GeV/c.

1 November 2024 in Journal of Instrumentation
Verified
Journal Article
Closed access
YYYan Yang
Yan Yang
HLHongbang Liu
Hongbang Liu
XLXiwen Liu
Xiwen Liu
CDCong Dai
Cong Dai
HHHuijun Hu
Huijun Hu
ELEnwei Liang
Enwei Liang
The side-on Transition Radiation Detector (TRD) is an essential component of the High Energy cosmic-Radiation Detection (HERD) facility aboard the China Space Station (CSS). Utilizing the proportional correlation between the Lorentz factor γ and Transition Radiation (TR) intensity, the side-on TRD collaborates with the HERD calorimeter for cross-calibration in the TeV energy range while orbiting. This paper focuses on analyzing and correcting signal crosstalk in the side-on TRD prototype. A signal caused by crosstalk, referred to as the “reversed polarity signal”, affects the particle signal and biases the prototype's energy measurement. To address the issue of energy deviation and select the most suitable capacitance for the prototype to correct crosstalk, we analyze the source of the reversed polarity signal and the effectiveness of adding a decoupling capacitor to the voltage divider circuit. Additionally, we use a combination of simulation and experimentation to investigate the specific relationship between the reversed polarity signal and the decoupling capacitance. The comparison between the simulation results and the experimental results show consistent trends. Measured energy spectra shows that correcting crosstalk eliminates a maximum measurement deviation of approximately 10.79% in the prototype. Following this correction, the side-on TRD prototype completed beam experiments in 2022.

1 October 2026 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
LXLirong Xie
Lirong Xie
SZShiqiang Zhou
Shiqiang Zhou
KCKai Chen
Kai Chen
ZFZuke Feng
Zuke Feng
DYDifan Yi
Difan Yi
HLHongbang Liu
Hongbang Liu

1 July 2026 in Journal of Instrumentation
Verified
Journal Article
Closed access
PDF file
XZXushuang Zhang
Xushuang Zhang
HHHuijun Hu
Huijun Hu
XLXiwen Liu
Xiwen Liu
CDCong Dai
Cong Dai
FJFan Jiang
Fan Jiang
ELEnwei Liang
Enwei Liang
The Transition Radiation Detector (TRD) onboard the High Energy cosmic-Radiation Detection (HERD) facility provides accurate energy calibration for the calorimeter (CALO) and serves as an independent gamma-ray burst trigger. Thick Gas Electron Multipliers (THGEMs) are the key elements enabling HERD-TRD to reach gains above 10 4 . However, the charging-up effect of THGEMs substantially narrows the stable observation window of the TRD during frequent in-orbit power cycles. In this study, 30, 60, and 90 nm high-resistivity CuO films were deposited on THGEM hole walls by magnetron sputtering to provide a leakage path for accumulated electrons. Temperature-dependent resistance of CuO-THGEM was systematically measured from -40 °C to 120 °C, and matched voltage-divider chains were designed for each CuO thickness. The 90 nm CuO-THGEM suffer from continuously decreasing gain caused by temperature-driven resistance reduction and the resulting divider shift. The results of 30 nm CuO-THGEM demonstrate that a high-resistivity CuO film can maintain the gain deviation of the THGEM within 0.69% under space-like cycling conditions.