It is known that photovoltaic generation may cause voltage variations and imbalances, harmonics of current and voltage, flickers, reverse power flow, additional aging in medium/low distribution transformers, and voltage regulators. A way to reduce these consequences is to select an adequate level of PV generation in the distribution systems. PV Hosting Capacity (PVHC) is intended to achieve this goal by the determination of the maximum PV generation allowed in the system. This work presents a practical method to calculate the PVHC in a medium voltage feeder, analyzing the relationship between the load factor of the distribution transformer and the voltage, the current, and the active power when the PV solar penetration level changes. The results allowed to conclude that there is a direct relationship between PV solar penetration level and a load factor of the distribution transformers.
El presente artículo describe los modelos de optimización recientemente aplicados al diseño y operación de los sistemas de potencia hacia la conformación de las redes inteligentes e identifica las tendencias, barreras y posibles brechas en esta área. Se describen modelos para optimizar el diseño y la operación de los sistemas de potencia considerando las energías renovables, la generación distribuida, las micro redes, la gestión de la demanda y los sistemas de almacenamiento de energía. Se concluyó que es necesario validar muchos de los modelos que se han formulado recientemente para la optimización de la operación mediante pruebas con datos reales y a gran escala. Además, la gestión de la demanda y las micro redes son aspectos en los cuales se requieren desarrollar modelos para el flujo óptimo de potencia. Finalmente, es necesario predecir con mayor precisión las variables estocásticas para que estos modelos se adapten al comportamiento real del sistema.
The growing integration of renewable energy sources and the electrification of multiple sectors have heightened the need for optimized planning and operation of modern electrical distribution systems. A critical challenge for distribution network operators is enhancing the resilience and reliability of their grids by identifying effective solutions. One promising approach to achieving this is through the deployment of battery energy storage systems, which can rapidly inject power to mitigate the impacts of network disturbances or outages. This study investigates the use of advanced genetic algorithms as a practical methodology for the optimal siting of batteries in modern distribution networks. By incorporating historical data on demand and network failures, the algorithm generates statistical models that inform the optimization process. The model integrates both the technical and economic aspects of battery systems to identify locations that minimize reliability indices such as SAIDI and SAIFI, while also reducing investment costs. Tested on a real distribution system comprising 1837 nodes, the proposed approach demonstrates the ability of genetic optimization to deliver efficient solutions compared with traditional methods, providing a high likelihood of identifying strategic battery locations that respond to variable demand, system failures, and technical constraints.
El uso de la generación distribuida con fuentes de energías renovables no convencionales y de sistemas de almacenamiento de energía ha propiciado el cambio de los sistemas tradicionales de distribución de energía hacia las microrredes eléctricas. La idea principal de esta investigación, es analizar el comportamiento de una microrred por medio de su modelado y simulación usando el programa computacional OpenDSS. Para ello, se modeló el sistema de prueba IEEE de 13 nodos modificado por medio de la ubicación de sistemas de almacenamiento de energía y plantas de generación -solar, eólica y diésel- distribuidas en diferentes puntos de la red de distribución. Lo anterior permite analizar las potencialidades de este software, así como las técnicas de modelado necesarias para su óptimo funcionamiento. Se verifica que el sistema, trabajando como microrred, mejora la eficiencia de la red de distribución en 51.5%.
Dissolved gas chromatography (DGA) analysis and Megger DC insulation tests are performed to diagnose the condition of a power transformer. In this context, the objective of this study is to assess whether there is a relationship between both types of tests. To this effect, a database with DGA and Megger DC test protocols is analyzed, using the theory of variable correlation as well as current DGA techniques. The results allow stating that there is indeed a relationship between both tests under specific conditions. Therefore, the DC isolation status of a transformer can be estimated via DGA tests.