Stephen Palmer

Stephen Palmer

Auto-generated profile, based on publicly available information

Stephen Palmer

Centre for Health Economics, University of York, York, UK

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2017 in Health Technology Assessment
Verified
Journal Article
Open access
PDF file
RHRobert Hettle
Robert Hettle
MCMark Corbett
Mark Corbett
SHSebastian Hinde
Sebastian Hinde
RHRobert Hodgson
Robert Hodgson
JJJulie Jones-Diette
Julie Jones-Diette
SPStephen Palmer
Stephen Palmer
Background: The National Institute for Health and Care Excellence (NICE) commissioned a ‘mock technology appraisal’ to assess whether changes to its methods and processes are needed. This report presents the findings of independent research commissioned to inform this appraisal and the deliberations of a panel convened by NICE to evaluate the mock appraisal.Methods: Our research included reviews to identify issues, analysis methods and conceptual differences and the relevance of alternative decision frameworks, alongside the development of an exemplar case study of chimeric antigen receptor (CAR) T-cell therapy for treating acute lymphoblastic leukaemia.Results: An assessment of previous evaluations of regenerative medicines found that, although there were a number of evidential challenges, none was unique to regenerative medicines or was beyond the scope of existing methods used to conceptualise decision uncertainty. Regarding the clinical evidence for regenerative medicines, the issues were those associated with a limited evidence base but were not unique to regenerative medicines: small non-randomised studies, high variation in response and the intervention subject to continuing development. The relative treatment effects generated from single-arm trials are likely to be optimistic unless it is certain that the historical data have accurately estimated the efficacy of the control agent. Pivotal trials may use surrogate end points, which, on average, overestimate treatment effects. To reduce overall uncertainty, multivariate meta-analysis of all available data should be considered. Incorporating indirectly relevant but more reliable (more mature) data into the analysis can also be considered; such data may become available as a result of the evolving regulatory pathways being developed by the European Medicines Agency. For the exemplar case of CAR T-cell therapy, target product profiles (TPPs) were developed, which considered the ‘curative’ and ‘bridging to stem-cell transplantation’ treatment approaches separately. Within each TPP, three ‘hypothetical’ evidence sets (minimum, intermediate and mature) were generated to simulate the impact of alternative levels of precision and maturity in the clinical evidence. Subsequent assessments of cost-effectiveness were undertaken, employing the existing NICE reference case alongside additional analyses suggested within alternative frameworks. The additional exploratory analyses were undertaken to demonstrate how assessments of cost-effectiveness and uncertainty could be impacted by alternative managed entry agreements (MEAs), including price discounts, performance-related schemes and technology leasing. The panel deliberated on the range of TPPs, evidence sets and MEAs, commenting on the likely recommendations for each scenario. The panel discussed the challenges associated with the exemplar and regenerative medicines more broadly, focusing on the need for a robust quantification of the level of uncertainty in the cost-effective estimates and the potential value of MEAs in limiting the exposure of the NHS to high upfront costs and loss associated with a wrong decision.Conclusions: It is to be expected that there will be a significant level of uncertainty in determining the clinical effectiveness of regenerative medicines and their long-term costs and benefits, but the existing methods available to estimate the implications of this uncertainty are sufficient. The use of risk sharing and MEAs between the NHS and manufacturers of regenerative medicines should be investigated further.Funding: The National Institute for Health Research Health Technology Assessment programme.

13 August 2020 in The European Journal of Health Economics
Verified
Journal Article
Closed access
PDF file
DCDoug Coyle
Doug Coyle
IDIsabelle Durand-Zaleski
Isabelle Durand-Zaleski
JFJasmine Farrington
Jasmine Farrington
LGLouis Garrison
Louis Garrison
JSJohann-Matthias Graf von der Schulenburg
Johann-Matthias Graf von der Schulenburg
KSKoonal Shah
Koonal Shah

1 July 2020 in Health Technology Assessment
Verified
Journal Article
Closed access
MRMark Rodgers
Mark Rodgers
DMDavid Marshall
David Marshall
MSMark Simmonds
Mark Simmonds
ACAnn Le Couteur
Ann Le Couteur
MBMousumi Biswas
Mousumi Biswas
RHRobert Hodgson
Robert Hodgson
Background: Early intensive applied behaviour analysis-based interventions are intensive interventions for autistic children that are often delivered on a one-to-one basis for 20–50 hours per week.Objectives: To evaluate the clinical effectiveness and cost-effectiveness of early intensive applied behaviour analysis-based interventions for autistic children, based on current evidence.Methods: A systematic review and individual participant data meta-analysis were conducted to evaluate the clinical effectiveness of an early intensive applied behaviour analysis-based intervention for autistic children. An economic analysis included a review of existing analyses and the development of a new model.Results: Twenty studies were included in the clinical review. Individual participant data were retrieved from 15 of these studies. Results favoured the interventions when assessing adaptive behaviour after 2 years compared with treatment as usual/eclectic interventions (mean difference 7.00, 95% confidence interval 1.95 to 12.06). In analyses of cognitive ability (intelligence quotient), results favoured the interventions by approximately 10 points after 1 year (mean difference 9.16, 95% confidence interval 4.38 to 13.93) and 2 years (mean difference 14.13, 95% confidence interval 9.16 to 19.10). Evidence for other outcomes was limited and meta-analyses were generally inconclusive. There was no evidence that the effect of the interventions varied with characteristics of the children, but data were limited. Adopting a £30,000 per quality-adjusted life-year threshold, the results of the cost-effectiveness analysis indicate that early intensive applied behaviour analysis-based interventions would need to generate larger benefits or cost savings to be cost-effective. Adopting a public sector perspective and making pessimistic assumptions about long-term effects, the incremental cost-effectiveness ratio for early intensive applied behaviour analysis-based therapy compared with treatment as usual is £189,122 per quality-adjusted life-year. When optimistic assumptions are made, the incremental cost-effectiveness ratio is £46,768 per quality-adjusted life-year. Scenario analyses indicated that these interventions can potentially be cost-effective if long-term improvements persist into adulthood, or if they have significant impact on educational placement. Care should be taken when interpreting these scenarios owing to the limited data.Limitations: All included studies were at risk of bias, there was substantial heterogeneity and effects varied considerably across studies. The effect of intervention on autism symptom severity, language development and school placement remains uncertain because of the limited data. The long-term effects are unclear owing to a lack of follow-up data.Conclusions: This review found limited evidence that early intensive applied behaviour analysis-based interventions may improve cognitive ability and adaptive behaviour, but the long-term impact of the interventions remains unknown. The economic analysis is constrained by the limited effectiveness evidence, but suggests that these interventions are unlikely to be cost-effective unless clear long-term benefits, or a substantial change in which schools children attend, can be identified.Future work: Further studies into the effectiveness of early intensive applied behaviour analysis-based interventions may be warranted if they include well-defined, alternative interventions as comparators and collect relevant outcomes. Consideration should be given to future studies that not only address whether or not early intensive applied behaviour analysis-based interventions are clinically effective, but also aim to identify which components of early intensive applied behaviour analysis-based interventions might drive effectiveness.Study registration: This study is registered as PROSPERO CRD42017068303.Funding: This project was funded by the National Institute for Health Research (NIHR) Health Technology Assessment programme and will be published in full inHealth Technology Assessment; Vol. 24, No. 35. See the NIHR Journals Library website for further project information.

1 December 2014 in Critical Care
Verified
Journal Article
Open access
PDF file
MSMarta O Soares
Marta O Soares
NWNicky J Welton
Nicky J Welton
DHDavid Harrison
David Harrison
PPPiia Peura
Piia Peura
MSManu Shankar-Hari
Manu Shankar-Hari
SPStephen J Palmer
Stephen J Palmer
Introduction: Prior to investing in a large, multicentre randomised controlled trial (RCT), the National Institute for Health Research in the UK called for an evaluation of the feasibility and value for money of undertaking a trial on intravenous immunoglobulin (IVIG) as an adjuvant therapy for severe sepsis/septic shock. Methods: In response to this call, this study assessed the clinical and cost-effectiveness of IVIG (using a decision model), and evaluated the value of conducting an RCT (using expected value of information (EVI) analysis). The evidence informing such assessments was obtained through a series of systematic reviews and meta-analyses. Further primary data analyses were also undertaken using the Intensive Care National Audit & Research Centre Case Mix Programme Database, and a Scottish Intensive Care Society research study. Results: We found a large degree of statistical heterogeneity in the clinical evidence on treatment effect, and the source of such heterogeneity was unclear. The incremental cost-effectiveness ratio of IVIG is within the borderline region of estimates considered to represent value for money, but results appear highly sensitive to the choice of model used for clinical effectiveness. This was also the case with EVI estimates, with maximum payoffs from conducting a further clinical trial between £137 and £1,011 million. Conclusions: Our analyses suggest that there is a need for a further RCT. Results on the value of conducting such research, however, were sensitive to the clinical effectiveness model used, reflecting the high level of heterogeneity in the evidence base.

1 March 2018 in Health Technology Assessment
Verified
Journal Article
Closed access
Pedro Saramago GoncalvesPedro Saramago Goncalves
Pedro Saramago Goncalves
HYHuiqin Yang
Huiqin Yang
ALAlexis Llewellyn
Alexis Llewellyn
RWRuth Walker
Ruth Walker
MHMelissa Harden
Melissa Harden
MSMark Simmonds
Mark Simmonds
Background: High-throughput non-invasive prenatal testing (NIPT) for fetal rhesus (D antigen) (RhD) status could avoid unnecessary treatment with routine anti-D immunoglobulin for RhD-negative women carrying a RhD-negative fetus, although this may lead to an increased risk of RhD sensitisations.Objectives: To systematically review the evidence on the diagnostic accuracy, clinical effectiveness and implementation of high-throughput NIPT and to develop a cost-effectiveness model.Methods: We searched MEDLINE and other databases, from inception to February 2016, for studies of high-throughput NIPT free-cell fetal deoxyribonucleic acid (DNA) tests of maternal plasma to determine fetal RhD status in RhD-negative pregnant women who were not known to be sensitised to the RhD antigen. Study quality was assessed with the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) and A Cochrane Risk of Bias Assessment Tool: for Non-Randomised Studies of Interventions (ACROBAT-NRSI). Summary estimates of false-positive rates (FPRs) and false-negative rates (FNRs) were calculated using bivariate models. Clinical effectiveness evidence was used to conduct a simulation study. We developed a de novo probabilistic decision tree-based cohort model that considered four alternative ways in which the results of NIPT could guide the use of anti-D immunoglobulin antenatally and post partum. Sensitivity analyses (SAs) were conducted to address key uncertainties and model assumptions.Results: Eight studies were included in the diagnostic accuracy review, seven studies were included in the clinical effectiveness review and 12 studies were included in the review of implementation. Meta-analyses included women mostly at or post 11 weeks’ gestation. The pooled FNR (women at risk of sensitisation) was 0.34% [95% confidence interval (CI) 0.15% to 0.76%] and the pooled FPR (women needlessly receiving anti-D) was 3.86% (95% CI 2.54% to 5.82%). SAs did not materially alter the overall results. Data on clinical outcomes, including sensitisation rates, were limited. Our simulation suggests that NIPT could substantially reduce unnecessary use of antenatal anti-D with only a small increase in the risk of sensitisation. All large implementation studies suggested that large-scale implementation of high-throughput NIPT was feasible. Seven cost-effectiveness studies were included in the review, which found that the potential for the use of NIPT to produce cost savings was dependent on the cost of the test. Our de novo model suggested that high-throughput NIPT is likely to be cost saving compared with the current practice of providing routine antenatal anti-D prophylaxis to all women who are RhD negative. The extent of the cost saving appeared to be sufficient to outweigh the small increase in sensitisations. However, the magnitude of the cost saving is highly sensitive to the cost of NIPT itself.Limitations: There was very limited evidence relating to the clinical effectiveness of high-throughput NIPT, with no evidence on potential adverse effects. The generalisability of the findings to non-white women and multiple pregnancies is unclear.Conclusions: High-throughput NIPT is sufficiently accurate to detect fetal RhD status in RhD-negative women from 11 weeks’ gestation and would considerably reduce unnecessary treatment with routine anti-D immunoglobulin, potentially resulting in cost savings of between £485,000 and £671,000 per 100,000 pregnancies if the cost of implementing NIPT is in line with that reflected in this evaluation.Future work: Further research on the diagnostic accuracy of NIPT in non-white women is needed.Study registration: This study is registered as PROSPERO CRD42015029497.Funding: The National Institute for Health Research Health Technology Assessment programme.

1 August 2020 in Health Technology Assessment
Verified
Journal Article
Closed access
MCMark Corbett
Mark Corbett
ADAna Duarte
Ana Duarte
ALAlexis Llewellyn
Alexis Llewellyn
JAJames Altunkaya
James Altunkaya
MHMelissa Harden
Melissa Harden
MSMarta Soares
Marta Soares
Background: Patients with low estimated glomerular filtration rates may be at higher risk of post-contrast acute kidney injury following contrast-enhanced computed tomography imaging. Point-of-care devices allow rapid measurement of estimated glomerular filtration rates for patients referred without a recent estimated glomerular filtration rate result. Objectives: To assess the clinical effectiveness and cost-effectiveness of point-of-care creatinine tests for outpatients without a recent estimated glomerular filtration rate measurement who need contrast-enhanced computed tomography imaging. Methods: Three systematic reviews of test accuracy, implementation and clinical outcomes, and economic analyses were carried out. Bibliographic databases were searched from inception to November 2018. Studies comparing the accuracy of point-of-care creatinine tests with laboratory reference tests to assess kidney function in adults in a non-emergency setting and studies reporting implementation and clinical outcomes were included. Risk of bias of diagnostic accuracy studies was assessed using a modified version of the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool. Probabilities of individuals having their estimated glomerular filtration rates correctly classified were estimated within a Bayesian framework and pooled using a fixed-effects model. A de novo probabilistic decision tree cohort model was developed to characterise the decision problem from an NHS and a Personal Social Services perspective. A range of alternative point-of-care testing approaches were considered. Scenario analyses were conducted. Results: Fifty-four studies were included in the clinical reviews. Twelve studies reported diagnostic accuracy for estimated glomerular filtration rates; half were rated as being at low risk of bias, but there were applicability concerns for most. i-STAT (Abbott Point of Care, Inc., Princeton, NJ, USA) and ABL (Radiometer Ltd, Crawley, UK) devices had higher probabilities of correctly classifying individuals in the same estimated glomerular filtration rate categories as the reference laboratory test than StatSensor® devices (Nova Biomedical, Runcorn, UK). There was limited evidence for epoc® (Siemens Healthineers AG, Erlangen, Germany) and Piccolo Xpress® (Abaxis, Inc., Union City, CA, USA) devices and no studies of DRI-CHEM NX 500 (Fujifilm Corporation, Tokyo, Japan). The review of implementation and clinical outcomes included six studies showing practice variation in the management decisions when a point-of-care device indicated an abnormal estimated glomerular filtration rate. The review of cost-effectiveness evidence identified no relevant studies. The de novo decision model that was developed included a total of 14 strategies. Owing to limited data, the model included only i-STAT, ABL800 FLEX and StatSensor. In the base-case analysis, the cost-effective strategy appeared to be a three-step testing sequence involving initially screening all individuals for risk factors, point-of-care testing for those individuals with at least one risk factor, and including a final confirmatory laboratory test for individuals with a point-of-care-positive test result. Within this testing approach, the specific point-of-care device with the highest net benefit was i-STAT, although differences in net benefit with StatSensor were very small. Limitations: There was insufficient evidence for patients with estimated glomerular filtration rates < 30 ml/minute/1.73 m2, and on the full potential health impact of delayed or rescheduled computed tomography scans or the use of alternative imaging modalities. Conclusions: A three-step testing sequence combining a risk factor questionnaire with a point-of-care test and confirmatory laboratory testing appears to be a cost-effective use of NHS resources compared with current practice. The risk of contrast causing acute kidney injury to patients with an estimated glomerular filtration rate of < 30 ml/minute/1.73 m2 is uncertain. Cost-effectiveness of point-of-care testing appears largely driven by the potential of point-of-care tests to minimise delays within the current computed tomography pathway. Future work: Studies evaluating the impact of risk-stratifying questionnaires on workflow outcomes in computed tomography patients without recent estimated glomerular filtration rate results are needed. Study registration: This study is registered as PROSPERO CRD42018115818. Funding: This project was funded by the National Institute for Health Research (NIHR) Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 24, No. 39. See the NIHR Journals Library website for further project information.