Ruth Walker

Ruth Walker

Auto-generated profile, based on publicly available information

Ruth Walker

Centre for Reviews and Dissemination, University of York, York, UK

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2018 in Health Technology Assessment
Verified
Journal Article
Closed access
Pedro Saramago GoncalvesPedro Saramago Goncalves
Pedro Saramago Goncalves
HYHuiqin Yang
Huiqin Yang
ALAlexis Llewellyn
Alexis Llewellyn
RWRuth Walker
Ruth Walker
MHMelissa Harden
Melissa Harden
MSMark Simmonds
Mark Simmonds
Background: High-throughput non-invasive prenatal testing (NIPT) for fetal rhesus (D antigen) (RhD) status could avoid unnecessary treatment with routine anti-D immunoglobulin for RhD-negative women carrying a RhD-negative fetus, although this may lead to an increased risk of RhD sensitisations.Objectives: To systematically review the evidence on the diagnostic accuracy, clinical effectiveness and implementation of high-throughput NIPT and to develop a cost-effectiveness model.Methods: We searched MEDLINE and other databases, from inception to February 2016, for studies of high-throughput NIPT free-cell fetal deoxyribonucleic acid (DNA) tests of maternal plasma to determine fetal RhD status in RhD-negative pregnant women who were not known to be sensitised to the RhD antigen. Study quality was assessed with the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) and A Cochrane Risk of Bias Assessment Tool: for Non-Randomised Studies of Interventions (ACROBAT-NRSI). Summary estimates of false-positive rates (FPRs) and false-negative rates (FNRs) were calculated using bivariate models. Clinical effectiveness evidence was used to conduct a simulation study. We developed a de novo probabilistic decision tree-based cohort model that considered four alternative ways in which the results of NIPT could guide the use of anti-D immunoglobulin antenatally and post partum. Sensitivity analyses (SAs) were conducted to address key uncertainties and model assumptions.Results: Eight studies were included in the diagnostic accuracy review, seven studies were included in the clinical effectiveness review and 12 studies were included in the review of implementation. Meta-analyses included women mostly at or post 11 weeks’ gestation. The pooled FNR (women at risk of sensitisation) was 0.34% [95% confidence interval (CI) 0.15% to 0.76%] and the pooled FPR (women needlessly receiving anti-D) was 3.86% (95% CI 2.54% to 5.82%). SAs did not materially alter the overall results. Data on clinical outcomes, including sensitisation rates, were limited. Our simulation suggests that NIPT could substantially reduce unnecessary use of antenatal anti-D with only a small increase in the risk of sensitisation. All large implementation studies suggested that large-scale implementation of high-throughput NIPT was feasible. Seven cost-effectiveness studies were included in the review, which found that the potential for the use of NIPT to produce cost savings was dependent on the cost of the test. Our de novo model suggested that high-throughput NIPT is likely to be cost saving compared with the current practice of providing routine antenatal anti-D prophylaxis to all women who are RhD negative. The extent of the cost saving appeared to be sufficient to outweigh the small increase in sensitisations. However, the magnitude of the cost saving is highly sensitive to the cost of NIPT itself.Limitations: There was very limited evidence relating to the clinical effectiveness of high-throughput NIPT, with no evidence on potential adverse effects. The generalisability of the findings to non-white women and multiple pregnancies is unclear.Conclusions: High-throughput NIPT is sufficiently accurate to detect fetal RhD status in RhD-negative women from 11 weeks’ gestation and would considerably reduce unnecessary treatment with routine anti-D immunoglobulin, potentially resulting in cost savings of between £485,000 and £671,000 per 100,000 pregnancies if the cost of implementing NIPT is in line with that reflected in this evaluation.Future work: Further research on the diagnostic accuracy of NIPT in non-white women is needed.Study registration: This study is registered as PROSPERO CRD42015029497.Funding: The National Institute for Health Research Health Technology Assessment programme.

1 December 2024 in Health Technology Assessment
Verified
Journal Article
Open access
PDF file
MSMark Simmonds
Mark Simmonds
ALAlexis Llewellyn
Alexis Llewellyn
RWRuth Walker
Ruth Walker
HFHelen Fulbright
Helen Fulbright
MWMatthew Walton
Matthew Walton
DSDavid H Steel
David H Steel
Background: Diabetic retinopathy is a major cause of sight loss in people with diabetes. The most severe form, proliferative diabetic retinopathy, carries a high risk of vision loss, vitreous haemorrhage, macular oedema and other harms. Panretinal photocoagulation is the primary treatment for proliferative diabetic retinopathy. Anti-vascular endothelial growth factor drugs are used to treat various eye conditions and may be beneficial for people with diabetic retinopathy. Objective: To investigate the efficacy and safety of anti-vascular endothelial growth factor therapy for the treatment of diabetic retinopathy when compared to panretinal photocoagulation. Methods: A systematic review and network meta-analysis of all published randomised controlled trials comparing anti-vascular endothelial growth factor (alone or in combination with panretinal photocoagulation) to panretinal photocoagulation in people with diabetic retinopathy. The database searches were updated in May 2023. Trials where the primary focus was treatment of macular oedema or vitreous haemorrhage were excluded. Results: A total of 14 trials were included: 3 of aflibercept, 5 of bevacizumab and 6 of ranibizumab. Two trials were of patients with non-proliferative diabetic retinopathy; all others were in proliferative diabetic retinopathy. Overall, anti-vascular endothelial growth factor was slightly better than panretinal photocoagulation at preventing vision loss, measured as best corrected visual acuity, at up to 2 years follow-up [mean difference in the logarithm of the minimum angle of resolution −0.089 (or 3.6 Early Treatment Diabetic Retinopathy Study letters), 95% confidence interval −0.180 to −0.019]. There was no clear evidence of any difference between the anti-vascular endothelial growth factors, but the potential for bias complicated the comparison. One trial found no benefit of anti-vascular endothelial growth factor over panretinal photocoagulation after 5 years. Anti-vascular endothelial growth factor was superior to panretinal photocoagulation at preventing macular oedema (relative risk 0.29, 95% confidence interval 0.18 to 0.49) and vitreous haemorrhage (relative risk 0.77, 95% confidence interval 0.61 to 0.99). There was no clear evidence that the effectiveness of anti-vascular endothelial growth factor varied over time. Conclusions: Anti-vascular endothelial growth factor injections reduce vision loss when compared to panretinal photocoagulation, but the benefit is small and unlikely to be clinically meaningful. Anti-vascular endothelial growth factor may have greater benefits for preventing complications such as macular oedema. Observational studies extending follow-up beyond the 1-year duration of most trials are needed to investigate the longer-term effects of repeated anti-vascular endothelial growth factor injections. Funding: This article presents independent research funded by the National Institute for Health and Care Research (NIHR) Health Technology Assessment programme as award number NIHR132948.

1 December 2022 in BMJ Open
Verified
Journal Article
Open access
PDF file
LBLucy Beresford
Lucy Beresford
RWRuth Walker
Ruth Walker
LSLesley Stewart
Lesley Stewart
Objectives During COVID-19, the International Prospective Register of Systematic Reviews (PROSPERO) experienced a surge in registrations for COVID-19-related systematic reviews, and duplication of research questions became apparent. Duplication can waste funding, time and research effort and make policy making more difficult. This project explored the extent of and reasons for duplication of COVID-19-related systematic review registrations in PROSPERO during the pandemic. Design Retrospective analysis of COVID-19-related registrations in PROSPERO, and a qualitative survey. Setting PROSPERO was searched for registrations related to four COVID-19 research areas: epidemiology, rehabilitation, transmission and treatments. Methods Records identified were compared using Population, Intervention/Exposure, Comparator, Outcome, Study Design (PICOS) elements of PROSPERO registration forms. Registrations with similar or identical PICOS were evaluated further as ‘duplicates’. Authors of ‘duplicate’ registrations were invited to complete a survey asking whether they searched PROSPERO prior to registration, identified similar reviews and, if so, why they continued with their review. Results 1054 COVID-19 reviews were registered between March 2020 and January 2021, of which 138 were submitted when at least one similar protocol was already registered in PROSPERO. Duplication was greatest in reviews of COVID-19 treatments; for example, there were 14 similar reviews evaluating the efficacy of hydroxychloroquine. From 138 authors invited to take part in the survey, we received 41 responses. Most respondents said that they identified similar reviews when they searched PROSPERO prior to registration. Main reasons given for ‘duplication’ were differences in PICOS or planned analyses (n=13), poor quality of previous registrations (n=2) and the need to update evidence (n=3). Conclusions This research highlights that registration of similar and duplicate systematic reviews related to COVID-19 in PROSPERO occurred frequently. Awareness of research waste is required, and initial checking for similar reviews should be embedded within good review practice.

1 October 2024 in Health Technology Assessment
Verified
Journal Article
Open access
PDF file
ALAlexis Llewellyn
Alexis Llewellyn
TPThai Han Phung
Thai Han Phung
MSMarta O Soares
Marta O Soares
LSLucy Shepherd
Lucy Shepherd
DGDavid Glynn
David Glynn
SDSofia Dias
Sofia Dias
Background: Magnetic resonance imaging localises cancer in the prostate, allowing for a targeted biopsy with or without transrectal ultrasound-guided systematic biopsy. Targeted biopsy methods include cognitive fusion, where prostate lesions suspicious on magnetic resonance imaging are targeted visually during live ultrasound, and software fusion, where computer software overlays the magnetic resonance imaging image onto the ultrasound in real time. The effectiveness and cost-effectiveness of software fusion technologies compared with cognitive fusion biopsy are uncertain. Objectives: To assess the clinical and cost-effectiveness of software fusion biopsy technologies in people with suspected localised and locally advanced prostate cancer. A systematic review was conducted to evaluate the diagnostic accuracy, clinical efficacy and practical implementation of nine software fusion devices compared to cognitive fusion biopsies, and with each other, in people with suspected prostate cancer. Comprehensive searches including MEDLINE, and Embase were conducted up to August 2022 to identify studies which compared software fusion and cognitive fusion biopsies in people with suspected prostate cancer. Risk of bias was assessed with quality assessment of diagnostic accuracy studies-comparative tool. A network meta-analysis comparing software and cognitive fusion with or without concomitant systematic biopsy, and systematic biopsy alone was conducted. Additional outcomes, including safety and usability, were synthesised narratively. A de novo decision model was developed to estimate the cost-effectiveness of targeted software fusion biopsy relative to cognitive fusion biopsy with or without concomitant systematic biopsy for prostate cancer identification in biopsy-naive people. Scenario analyses were undertaken to explore the robustness of the results to variation in the model data sources and alternative assumptions. Results: Twenty-three studies (3773 patients with software fusion, 2154 cognitive fusion) were included, of which 13 informed the main meta-analyses. Evidence was available for seven of the nine fusion devices specified in the protocol and at high risk of bias. The meta-analyses show that patients undergoing software fusion biopsy may have: (1) a lower probability of being classified as not having cancer, (2) similar probability of being classified as having non-clinically significant cancer (International Society of Urological Pathology grade 1) and (3) higher probability of being classified at higher International Society of Urological Pathology grades, particularly International Society of Urological Pathology 2. Similar results were obtained when comparing between same biopsy methods where both were combined with systematic biopsy. Evidence was insufficient to conclude whether any individual devices were superior to cognitive fusion, or whether some software fusion technologies were superior to others. Uncertainty in the relative diagnostic accuracy of software fusion versus cognitive fusion reduce the strength of any statements on its cost-effectiveness. The economic analysis suggests incremental cost-effectiveness ratios for software fusion biopsy versus cognitive fusion are within the bounds of cost-effectiveness (£1826 and £5623 per additional quality-adjusted life-year with or with concomitant systematic biopsy, respectively), but this finding needs cautious interpretation. Limitations: There was insufficient evidence to explore the impact of effect modifiers. Conclusions: Software fusion biopsies may be associated with increased cancer detection in relation to cognitive fusion biopsies, but the evidence is at high risk of bias. Sufficiently powered, high-quality studies are required. Cost-effectiveness results should be interpreted with caution given the limitations of the diagnostic accuracy evidence. Study registration: This trial is registered as PROSPERO CRD42022329259. Funding: This award was funded by the National Institute for Health and Care Research (NIHR) Evidence Synthesis programme (NIHR award ref: 135477) and is published in full in Health Technology Assessment; Vol. 28, No. 61. See the NIHR Funding and Awards website for further information.

28 October 2022 in Systematic Reviews
Verified
Journal Article
Open access
PDF file
CKClaire Khouja
Claire Khouja
GBGinny Brunton
Ginny Brunton
MRMichelle Richardson
Michelle Richardson
GSGillian Stokes
Gillian Stokes
LBLaurence Blanchard
Laurence Blanchard
JTJames Thomas
James Thomas
Background: This systematic overview was commissioned by England’s Department of Health and Social Care (DHSC) to assess the evidence on direct (previously ‘novel’) oral anticoagulants (OACs), compared with usual care, in adults, to prevent stroke related to atrial fibrillation (AF), and to prevent and treat venous thromboembolism (VTE). Specifically, to assess efficacy and safety, genotyping, self-monitoring, and patient and clinician experiences of OACs. Methods: We searched MEDLINE, Embase, ASSIA, and CINAHL, in October, 2017, updated in November 2021. We included systematic reviews, published from 2014, in English, assessing OACs, in adults. We rated review quality using AMSTAR2 or the JBI checklist. Two reviewers extracted and synthesised the main findings from the included reviews. Results: We included 49 systematic reviews; one evaluated efficacy, safety, and cost-effectiveness, 17 assessed genotyping, 23 self-monitoring or adherence, and 15 experiences (seven assessed two topics). Generally, the direct OACs, particularly apixaban (5 mg twice daily), were more effective and safer than warfarin in preventing AF-related stroke. For VTE, there was little evidence of differences in efficacy between direct OACs and low-molecular-weight heparin (prevention), warfarin (treatment), and warfarin or aspirin (secondary prevention). The evidence suggested that some direct OACs may reduce the risk of bleeding, compared with warfarin. One review of genotype-guided warfarin dosing assessed AF patients; no significant differences in stroke prevention were reported. Education about OACs, in patients with AF, could improve adherence. Pharmacist management of coagulation may be better than primary care management. Patients were more adherent to direct OACs than warfarin. Drug efficacy was highly valued by patients and most clinicians, followed by safety. No other factors consistently affected patients’ choice of anticoagulant and adherence to treatment. Patients were more satisfied with direct OACs than warfarin. Conclusions: For stroke prevention in AF, direct OACs seem to be more effective and safer than usual care, and apixaban (5 mg twice daily) had the best profile. For VTE, there was no strong evidence that direct OACs were better than usual care. Education and pharmacist management could improve coagulation control. Both clinicians and patients rated efficacy and safety as the most important factors in managing AF and VTE. Systematic review registration: PROSPERO CRD42017084263—one deviation; efficacy and safety were from one review.

1 April 2025 in Health Technology Assessment
Verified
Journal Article
Open access
MSMark Simmonds
Mark Simmonds
ALAlexis Llewellyn
Alexis Llewellyn
RWRuth Walker
Ruth Walker
HFHelen Fulbright
Helen Fulbright
MWMatthew Walton
Matthew Walton
DSDavid H Steel
David H Steel
Background: Proliferative diabetic retinopathy is a major cause of sight loss in people with diabetes, with a high risk of vitreous haemorrhage, tractional retinal detachment and other complications. Panretinal photocoagulation is the primary established treatment for proliferative diabetic retinopathy. Anti-vascular endothelial growth factor drugs are used to treat various eye conditions and may be beneficial for people with proliferative diabetic retinopathy. Objective: To investigate the efficacy and safety of anti-vascular endothelial growth factor therapy for the treatment of proliferative diabetic retinopathy when compared to panretinal photocoagulation. Methods: A systematic review and network meta-analysis of randomised controlled trials comparing anti-vascular endothelial growth factor (alone or in combination) to panretinal photocoagulation in people with proliferative diabetic retinopathy. The database searches were updated in May 2023. Trials where the primary focus was treatment of macular oedema or vitreous haemorrhage were excluded. Key outcomes were best corrected visual acuity, diabetic macular oedema and vitreous haemorrhage. Individual participant data were obtained and analysed for three large, high-quality trials in combination with published data from other trials. Network meta-analyses of best corrected visual acuity and meta-analyses of other outcomes combined individual participant data with published data from other trials; regression analyses against patient covariates used just the individual participant data. Results: Twelve trials were included: one of aflibercept, five of bevacizumab and six of ranibizumab. Individual participant data were available from 1 aflibercept and 2 ranibizumab trials, representing 624 patients (33% of the total). When considered together, anti-vascular endothelial growth factors produced a modest, but not clinically meaningful, benefit over panretinal photocoagulation in best corrected visual acuity, after 1 year of follow-up (mean difference in logarithm of the minimum angle of resolution −0.116, 95% credible interval −0.183 to −0.038). There was no clear evidence of a difference in effectiveness between the anti-vascular endothelial growth factors. The benefit of anti-vascular endothelial growth factor appears to decline over time. Analysis of the individual participant data trials suggested that anti-vascular endothelial growth factor therapy may be more effective in people with poorer visual acuity, in those who have vitreous haemorrhage and, possibly, in people with poorer vision generally. Anti-vascular endothelial growth factor was superior to panretinal photocoagulation at preventing macular oedema after 1 year (relative risk 0.48, 95% confidence interval 0.28 to 0.83) and possibly at preventing vitreous haemorrhage (relative risk 0.72, 95% confidence interval 0.47 to 1.10). Anti-vascular endothelial growth factor reduced the incidence of retinal detachment when compared to panretinal photocoagulation (relative risk 0.41, 95% confidence interval 0.22 to 0.77). Data on other adverse events were generally too limited to identify any differences between anti-vascular endothelial growth factor and panretinal photocoagulation. Conclusions: Anti-vascular endothelial growth factor has no clinically meaningful benefit over panretinal photocoagulation for preserving visual acuity. However, anti-vascular endothelial growth factor therapy appears to delay or prevent progression to macular oedema and vitreous haemorrhage. The possibility that anti-vascular endothelial growth factor therapy may be more effective in patients with poorer health and poorer vision merits further clinical investigation. The long-term effectiveness and safety of anti-vascular endothelial growth factor treatment are unclear, particularly as additional panretinal photocoagulation and anti-vascular endothelial growth factor treatment will be required over time. Funding: This article presents independent research funded by the National Institute for Health and Care Research (NIHR) Health Technology Assessment programme as award number NIHR132948.