This letter presents a double-tuned dual input transmitter coil operating at 13.56 and 40.68 MHz industrial, scientific, and medical (ISM) bands for multisite biomedical applications. The proposed system removes the need for two separate coils, which reduces system size and unwanted couplings. The design and analysis of the double-tuned transmitter coil using a lumped element frequency trap are discussed in this letter. The transmitter achieves measured matching of $-$ 26.2 and $-$ 21.5 dB and isolation of $-$ 17.7 and $-$ 11.7 dB at 13.56 and 40.68 MHz, respectively. A 3 $\times$ 15 mm flexible coil is used as an implantable receiver. This letter shows synchronized multisite stimulation of two flexible implants at a distance of 2 cm while covered with 1 cm chicken breast.
Fracture mapping is essential in hydraulic fracturing and finds applications in the oil and gas industry. Mapping of fractures using traditional radioactive or microseismic methods involves contamination and is prone to being inaccurate, thereby reducing the yield in fracturing applications. Therefore, wireless sensor networks (WSNs) with each sensing node having a small form factor and low power consumption are currently being investigated for use in such applications. This paper presents a fully battery-less system of coherent sensing nodes using wireless energy harvesting. These nodes are capable of mapping fractures reliably at temperatures up to 250 °C and pressures up to 24 MPa. Each node comprises a microchip having dimensions of 1.1 mm X 0.56 mm, two coils of 8 mm diameter each, and resonating capacitors. The microchip was fabricated in the Taiwan Semiconductor Manufacturing Company (TSMC) 0.18 μm process. The node receives a 40.68 MHz radio frequency (RF) signal in the industrial, scientific, and medical applications (ISM) band and transmits back a locked sub-harmonic 13.56 MHz ISM band RF signal. The sub-harmonic signal is generated on-chip using a digital divide-by-3 circuit, drastically reducing the microchip power consumption compared to injection-locked oscillators or phase-locked loops (PLLs). The sensor nodes used in the system have a form factor of 17 mm X 12 mm X 0.2 mm and a minimum average power consumption of 1.5 μW.
26 June 2023 in IEEE Transactions on Biomedical Circuits and Systems
Localization has varied applications in biomedicine, such as wireless capsule endoscopy (WCE), detection of cancerous tissue, drug delivery, robotic surgeries, and brain mapping. Currently, most localization systems are battery-powered and suffer from issues regarding battery leakage and limited battery life, resulting in potential health hazards and inconveniences when using them for continuous health monitoring applications. This paper proposes an entirely wireless and battery-less 2D localization system consisting of an integrated circuit (IC) that is wirelessly powered at a distance of 4 cm by a 40.68 MHz radio frequency (RF) power of only 2 W. The proposed localization system wirelessly transmits a locked sub-harmonic 13.56 MHz signal generated from the wirelessly received 40.68 MHz RF power signal, eliminating the need for a power-hungry oscillator. Additionally, the system, having a measurement latency of 11.3 ms, has also been verified to sense motion as small as 50 $\mu m$ as well as measure the rate of motion up to 10 beats per minute, therefore extending its application to the detection of physiological motions such as diaphragm motion during breathing. The localizer has a small form factor of 17 mm × 12 mm × 0.2 mm and consumes an average power of 6 $\mu$ W. Ex vivo measurements using the localizer inside the porcine intestine demonstrate a localization accuracy of less than 5 mm.