Christoph Arthofer

Christoph Arthofer

Auto-generated profile, based on publicly available information

Christoph Arthofer

Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, United Kingdom

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 March 2022 in Nature
Verified
Journal Article
Open access
PDF file
GDGwenaëlle Douaud
Gwenaëlle Douaud
SLSoojin Lee
Soojin Lee
FAFidel Alfaro-Almagro
Fidel Alfaro-Almagro
CAChristoph Arthofer
Christoph Arthofer
CWChaoyue Wang
Chaoyue Wang
SSStephen M. Smith
Stephen M. Smith
There is strong evidence of brain-related abnormalities in COVID-191–13. However, it remains unknown whether the impact of SARS-CoV-2 infection can be detected in milder cases, and whether this can reveal possible mechanisms contributing to brain pathology. Here we investigated brain changes in 785 participants of UK Biobank (aged 51–81 years) who were imaged twice using magnetic resonance imaging, including 401 cases who tested positive for infection with SARS-CoV-2 between their two scans—with 141 days on average separating their diagnosis and the second scan—as well as 384 controls. The availability of pre-infection imaging data reduces the likelihood of pre-existing risk factors being misinterpreted as disease effects. We identified significant longitudinal effects when comparing the two groups, including (1) a greater reduction in grey matter thickness and tissue contrast in the orbitofrontal cortex and parahippocampal gyrus; (2) greater changes in markers of tissue damage in regions that are functionally connected to the primary olfactory cortex; and (3) a greater reduction in global brain size in the SARS-CoV-2 cases. The participants who were infected with SARS-CoV-2 also showed on average a greater cognitive decline between the two time points. Importantly, these imaging and cognitive longitudinal effects were still observed after excluding the 15 patients who had been hospitalised. These mainly limbic brain imaging results may be the in vivo hallmarks of a degenerative spread of the disease through olfactory pathways, of neuroinflammatory events, or of the loss of sensory input due to anosmia. Whether this deleterious effect can be partially reversed, or whether these effects will persist in the long term, remains to be investigated with additional follow-up.

1 January 2021 in eClinicalMedicine
Verified
Journal Article
Open access
BRBetty Raman
Betty Raman
MCMark Philip Cassar
Mark Philip Cassar
ETElizabeth M. Tunnicliffe
Elizabeth M. Tunnicliffe
NFNicola Filippini
Nicola Filippini
LGLudovica Griffanti
Ludovica Griffanti
SNStefan Neubauer
Stefan Neubauer
The medium-term effects of Coronavirus disease (COVID-19) on organ health, exercise capacity, cognition, quality of life and mental health are poorly understood. Fifty-eight COVID-19 patients post-hospital discharge and 30 age, sex, body mass index comorbidity-matched controls were enrolled for multiorgan (brain, lungs, heart, liver and kidneys) magnetic resonance imaging (MRI), spirometry, six-minute walk test, cardiopulmonary exercise test (CPET), quality of life, cognitive and mental health assessments. At 2–3 months from disease-onset, 64% of patients experienced breathlessness and 55% reported fatigue. On MRI, abnormalities were seen in lungs (60%), heart (26%), liver (10%) and kidneys (29%). Patients exhibited changes in the thalamus, posterior thalamic radiations and sagittal stratum on brain MRI and demonstrated impaired cognitive performance, specifically in the executive and visuospatial domains. Exercise tolerance (maximal oxygen consumption and ventilatory efficiency on CPET) and six-minute walk distance were significantly reduced. The extent of extra-pulmonary MRI abnormalities and exercise intolerance correlated with serum markers of inflammation and acute illness severity. Patients had a higher burden of self-reported symptoms of depression and experienced significant impairment in all domains of quality of life compared to controls (p<0.0001 to 0.044). A significant proportion of patients discharged from hospital reported symptoms of breathlessness, fatigue, depression and had limited exercise capacity. Persistent lung and extra-pulmonary organ MRI findings are common in patients and linked to inflammation and severity of acute illness. NIHR Oxford and Oxford Health Biomedical Research Centres, British Heart Foundation Centre for Research Excellence, UKRI, Wellcome Trust, British Heart Foundation.

29 September 2022 in PLOS ONE
Verified
Journal Article
Open access
PDF file
EDEugene Duff
Eugene Duff
FZFernando Zelaya
Fernando Zelaya
FAFidel Alfaro Almagro
Fidel Alfaro Almagro
KMKarla L. Miller
Karla L. Miller
NMNaomi Martin
Naomi Martin
OCon behalf of the COVID-CNS Consortium
on behalf of the COVID-CNS Consortium
Introduction: Magnetic resonance imaging (MRI) of the brain could be a key diagnostic and research tool for understanding the neuropsychiatric complications of COVID-19. For maximum impact, multi-modal MRI protocols will be needed to measure the effects of SARS-CoV-2 infection on the brain by diverse potentially pathogenic mechanisms, and with high reliability across multiple sites and scanner manufacturers. Here we describe the development of such a protocol, based upon the UK Biobank, and its validation with a travelling heads study. A multi-modal brain MRI protocol comprising sequences for T1-weighted MRI, T2-FLAIR, diffusion MRI (dMRI), resting-state functional MRI (fMRI), susceptibility-weighted imaging (swMRI), and arterial spin labelling (ASL), was defined in close approximation to prior UK Biobank (UKB) and C-MORE protocols for Siemens 3T systems. We iteratively defined a comparable set of sequences for General Electric (GE) 3T systems. To assess multi-site feasibility and between-site variability of this protocol, N = 8 healthy participants were each scanned at 4 UK sites: 3 using Siemens PRISMA scanners (Cambridge, Liverpool, Oxford) and 1 using a GE scanner (King’s College London). Over 2,000 Imaging Derived Phenotypes (IDPs), measuring both data quality and regional image properties of interest, were automatically estimated by customised UKB image processing pipelines (S2 File). Components of variance and intra-class correlations (ICCs) were estimated for each IDP by linear mixed effects models and benchmarked by comparison to repeated measurements of the same IDPs from UKB participants. Intra-class correlations for many IDPs indicated good-to-excellent between-site reliability. Considering only data from the Siemens sites, between-site reliability generally matched the high levels of test-retest reliability of the same IDPs estimated in repeated, within-site, within-subject scans from UK Biobank. Inclusion of the GE site resulted in good-to-excellent reliability for many IDPs, although there were significant between-site differences in mean and scaling, and reduced ICCs, for some classes of IDP, especially T1 contrast and some dMRI-derived measures. We also identified high reliability of quantitative susceptibility mapping (QSM) IDPs derived from swMRI images, multi-network ICA-based IDPs from resting-state fMRI, and olfactory bulb structure IDPs from T1, T2-FLAIR and dMRI data. Conclusion: These results give confidence that large, multi-site MRI datasets can be collected reliably at different sites across the diverse range of MRI modalities and IDPs that could be mechanistically informative in COVID brain research. We discuss limitations of the study and strategies for further harmonisation of data collected from sites using scanners supplied by different manufacturers. These acquisition and analysis protocols are now in use for MRI assessments of post-COVID patients (N = 700) as part of the ongoing COVID-CNS study.

1 September 2020 in European Journal of Radiology
Verified
Journal Article
Closed access
SSShahideh Safavi
Shahideh Safavi
CAChristoph Arthofer
Christoph Arthofer
ACAndrew Cooper
Andrew Cooper
JHJames W. Harkin
James W. Harkin
APAndrew P. Prayle
Andrew P. Prayle
IHIan P. Hall
Ian P. Hall

25 November 2024 in Imaging Neuroscience
Verified
Journal Article
Open access
CAChristoph Arthofer
Christoph Arthofer
SSStephen M. Smith
Stephen M. Smith
GDGwenaëlle Douaud
Gwenaëlle Douaud
ABAndreas Bartsch
Andreas Bartsch
FAFidel Alfaro-Almagro
Fidel Alfaro-Almagro
FLFrederik J. Lange
Frederik J. Lange
Anatomical magnetic resonance imaging (MRI) templates of the brain are essential to group-level analyses and image processing pipelines, as they provide a reference space for spatial normalisation. While it has become common for studies to acquire multimodal MRI data, many templates are still limited to one type of modality, usually either scalar or tensor based. Aligning each modality in isolation does not take full advantage of the available complementary information, such as strong contrast between tissue types in structural images, or axonal organisation in the white matter in diffusion tensor images. Most existing strategies for multimodal template construction either do not use all modalities of interest to inform the template construction process, or do not use them in a unified framework. Here, we present multimodal, cross-sectional templates constructed from UK Biobank data: the Oxford-MultiModal-1 (OMM-1) template and age-dependent templates for each year of life between 45 and 81 years. All templates are fully unbiased to represent the average shape of the populations they were constructed from, and internally consistent through jointly informing the template construction process with T1-weighted (T1), T2-weighted fluid-attenuated inversion recovery (T2-FLAIR), and diffusion tensor imaging (DTI) data. The OMM-1 template was constructed with a multiresolution, iterative approach using 240 individuals in the 50–55-year age range. The age-dependent templates were estimated using a Gaussian process, which describes the change in average brain shape with age in 37,330 individuals. All templates show excellent contrast and alignment within and between modalities. The global brain shape and size are not preconditioned on existing templates, although maximal possible compatibility with MNI-152 space was maintained through rigid alignment. We showed benefits in registration accuracy across two datasets (UK Biobank and HCP), when using the OMM-1 as the template compared with FSL’s MNI-152 template, and found that the use of age-dependent templates further improved accuracy to a small but detectable extent. All templates are publicly available and can be used as a new reference space for uni- or multimodal spatial alignment.

1 September 2020 in bioRxiv
Verified
Preprint
Open access
PDF file
EPEdward J Peake
Edward J Peake
RCRaphael Chevasson
Raphael Chevasson
SPStefan Pszczolkowski
Stefan Pszczolkowski
DADorothee P Auer
Dorothee P Auer
CAChristoph Arthofer
Christoph Arthofer
Purpose: To evaluate the performance of an ensemble learning approach for fully automated cartilage segmentation on knee magnetic resonance images of patients with osteoarthritis. Materials and Methods: This retrospective study of 88 participants with knee osteoarthritis involved the study of three-dimensional (3D) double echo steady state (DESS) MR imaging volumes with manual segmentations for 6 different compartments of cartilage (Data available from the Osteoarthritis Initiative). We propose ensemble learning to boost the sensitivity of our deep learning method by combining predictions from two models, a U-Net for the segmentation of two labels (cartilage vs background) and a multi-label U-Net for specific cartilage compartments. Segmentation accuracy is evaluated using Dice coefficient, while volumetric measures and Bland Altman plots provide complimentary information when assessing segmentation results. Results: Our model showed excellent accuracy for all 6 cartilage locations: femoral 0.88, medial tibial 0.84, lateral tibial 0.88, patellar 0.85, medial meniscal 0.85 and lateral meniscal 0.90. The average volume correlation was 0.988, overestimating volume by 9% ± 14% over all compartments. Simple post processing creates a single 3D connected component per compartment resulting in higher anatomical face validity. Conclusion: Our model produces automated segmentation with high Dice coefficients when compared to expert manual annotations and leads to the recovery of missing labels in the manual annotations, while also creating smoother, more realistic boundaries avoiding slice discontinuity artifacts present in the manual annotations. Key Results: Combining a 2-label U-Net (cartilage vs background) with a multi-class U-Net for segmentation of cartilage compartment boosts the accuracy of our deep learning model leading to the recovery of missing annotations in the manual dataset. Automatically generated segmentations have high Dice coefficients (0.85-0.90) and reduce inter-slice discontinuity artefact caused by slice wise delineation. Model refinement yields more anatomically plausible segmentations where each cartilage label is composed of only a single 3D region of interest.