Ramasamy Meyyappan

Ramasamy Meyyappan

Auto-generated profile, based on publicly available information

Ramasamy Meyyappan

Lungpacer Medical Inc., Burnaby, British Columbia, Canada; and

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2017 in American Journal of Respiratory and Critical Care Medicine
Verified
Journal Article
Closed access
SRSteven C. Reynolds
Steven C. Reynolds
RMRamasamy Meyyappan
Ramasamy Meyyappan
VTViral Thakkar
Viral Thakkar
BTBao D. Tran
Bao D. Tran
MNMarc-André Nolette
Marc-André Nolette
JHJoaquín Andrés Hoffer
Joaquín Andrés Hoffer
Rationale: Ventilator-induced diaphragm dysfunction is a significant contributor to weaning difficulty in ventilated critically ill patients. It has been hypothesized that electrically pacing the diaphragm during mechanical ventilation could reduce diaphragm dysfunction. Objectives: We tested a novel, central line catheter–based, transvenous phrenic nerve pacing therapy for protecting the diaphragm in sedated and ventilated pigs. Methods: Eighteen Yorkshire pigs were studied. Six pigs were sedated and mechanically ventilated for 2.5 days with pacing on alternate breaths at intensities that reduced the ventilator pressure–time product by 20–30%. Six matched subjects were similarly sedated and ventilated but were not paced. Six pigs served as never-ventilated, never-paced control animals. Measurements and Main Results: Cumulative duration of pacing therapy ranged from 19.7 to 35.7 hours. Diaphragm thickness assessed by ultrasound and normalized to initial value showed a significant decline in ventilated–not paced but not in ventilated-paced subjects (0.84 [interquartile range (IQR), 0.78–0.89] vs. 1.10 [IQR, 1.02–1.24]; P = 0.001). Compared with control animals (24.6 μm2/kg; IQR, 21.6–26.0), median myofiber cross-sectional areas normalized to weight and sarcomere length were significantly smaller in the ventilated–not paced (17.9 μm2/kg; IQR, 15.3–23.7; P = 0.005) but not in the ventilated-paced group (24.9 μm2/kg; IQR, 16.6–27.3; P = 0.351). After 60 hours of mechanical ventilation all six ventilated-paced subjects tolerated 8 minutes of intense phrenic stimulation, whereas three of six ventilated–not paced subjects did not (P = 0.055). There was a nonsignificant decrease in diaphragm tetanic force production over the experiment in the ventilated-paced and ventilated–not paced groups. Conclusions: These results suggest that early transvenous phrenic nerve pacing may mitigate ventilator-induced diaphragm dysfunction.