Patrick Schuller

Patrick Schuller

Auto-generated profile, based on publicly available information

Patrick Schuller

Institute of Applied Synthetic Chemistry, Faculty of Technical Chemistry, Vienna University of Technology, Getreidemarkt 9/163, 1060 Vienna, Austria

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 September 2019 in Biosensors
Verified
Journal Article
Open access
PDF file
SKSebastian Rudi Adam Kratz
Sebastian Rudi Adam Kratz
GHGregor Höll
Gregor Höll
PSPatrick Schuller
Patrick Schuller
PEPeter Ertl
Peter Ertl
MRMario Rothbauer
Mario Rothbauer
Organs-on-chips are considered next generation in vitro tools capable of recreating in vivo like, physiological-relevant microenvironments needed to cultivate 3D tissue-engineered constructs (e.g., hydrogel-based organoids and spheroids) as well as tissue barriers. These microphysiological systems are ideally suited to (a) reduce animal testing by generating human organ models, (b) facilitate drug development and (c) perform personalized medicine by integrating patient-derived cells and patient-derived induced pluripotent stem cells (iPSCs) into microfluidic devices. An important aspect of any diagnostic device and cell analysis platform, however, is the integration and application of a variety of sensing strategies to provide reliable, high-content information on the health status of the in vitro model of choice. To overcome the analytical limitations of organs-on-a-chip systems a variety of biosensors have been integrated to provide continuous data on organ-specific reactions and dynamic tissue responses. Here, we review the latest trends in biosensors fit for monitoring human physiology in organs-on-a-chip systems including optical and electrochemical biosensors.

23 March 2020 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
MRMario Rothbauer
Mario Rothbauer
GHGregor Höll
Gregor Höll
CEChristoph Eilenberger
Christoph Eilenberger
SKSebastian R A Kratz
Sebastian R A Kratz
BFBilal Farooq
Bilal Farooq
PEPeter Ertl
Peter Ertl
We demonstrate that the integration of complex human synovial organ cultures in a lab-on-a-chip provides reproducible and reliable information on how systemic stress factors affect synovial tissue architectures using light scatter biosensing.

26 June 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
SKS. R. A. Kratz
S. R. A. Kratz
CEC. Eilenberger
C. Eilenberger
PSP. Schuller
P. Schuller
BBBarbara Bachmann
Barbara Bachmann
SSSarah Spitz
Sarah Spitz
MRMario Rothbauer
Mario Rothbauer
In the advent of affordable photo- and soft-lithography using polydimethylsiloxane (PDMS), low cost multi-step microfabrication methods have become available to a broad scientific community today. Although these methods are frequently applied for microfluidic prototype production in academic and industrial settings, fast design iterations and rapid prototyping within a few minutes with a high degree of flexibility are nearly impossible. To reduce microfluidic concept-to-chip time and costs, a number of alternative rapid prototyping techniques have recently been introduced including CNC micromachining, 3D printing and plotting out of numeric CAD designs as well as micro-structuring of thin PDMS sheets and pressure sensitive adhesives. Although micro-structuring of pressure sensitive adhesives promises high design flexibility, rapid fabrication and simple biochip assembly, most adhesives are toxic for living biological systems. Since an appropriate bio-interface and proper biology-material interaction is key for any cell chip and organ-on-a-chip system, only a limited number of medical-grade materials are available for microfluidic prototyping. In this study, we have characterized four functional biomedical-grade pressure sensitive adhesives for rapid prototyping (e.g. less than 1 hour) applications including structuring precision, physical and optical properties as well as biocompatibilities. While similar biocompatibility was found for all four adhesives, significant differences in cutting behavior, bonding strength to glass and polymers as well as gas permeability was observed. Practical applications included stability testing of multilayered, membrane-integrated organ-on-a-chip devices under standard cell culture conditions (e.g. 2–3 weeks at 37 °C and 100% humidity) and a shear-impact up to 5 dynes/cm2. Additionally, time- and shear-dependent uptake of non-toxic fluorescently labelled nanoparticles on human endothelial cells are demonstrated using micro-structured adhesive-bonded devices. Our results show that (a) both simple and complex microdevices can be designed, fabricated and tested in less than 1 hour, (b) these microdevices are stable for weeks even under physiological shear force conditions and (c) can be used to maintain cell monolayers as well as 3D cell culture systems.

1 June 2020 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
PSPatrick Schuller
Patrick Schuller
MRMario Rothbauer
Mario Rothbauer
SKSebastian R.A. Kratz
Sebastian R.A. Kratz
GHGregor Höll
Gregor Höll
PTPhillipp Taus
Phillipp Taus
PEPeter Ertl
Peter Ertl

20 June 2018 in Biomicrofluidics
Verified
Journal Article
Closed access
PDF file
BBBarbara Bachmann
Barbara Bachmann
SSSarah Spitz
Sarah Spitz
MRMario Rothbauer
Mario Rothbauer
CJChristian Jordan
Christian Jordan
MPMichaela Purtscher
Michaela Purtscher
PEPeter Ertl
Peter Ertl
Reengineering functional vascular networks in vitro remains an integral part in tissue engineering, since the incorporation of non-perfused tissues results in restricted nutrient supply and limited waste removal. Microfluidic devices are routinely used to mimic both physiological and pathological vascular microenvironments. Current procedures either involve the investigation of growth factor gradients and interstitial flow on endothelial cell sprouting alone or on the heterotypic cell-cell interactions between endothelial and mural cells. However, limited research has been conducted on the influence of flow on co-cultures of these cells. Here, we exploited the ability of microfluidics to create and monitor spatiotemporal gradients to investigate the influence of growth factor supply and elution on vascularization using static as well as indirect and direct flow setups. Co-cultures of human adipose-derived stem/stromal cells and human umbilical vein endothelial cells embedded in fibrin hydrogels were found to be severely affected by diffusion limited growth factor gradients as well as by elution of reciprocal signaling molecules during both static and flow conditions. Static cultures formed pre-vascular networks up to a depth of 4 mm into the construct with subsequent decline due to diffusion limitation. In contrast, indirect flow conditions enhanced endothelial cell sprouting but failed to form vascular networks. Additionally, complete inhibition of pre-vascular network formation was observable for direct application of flow through the hydrogel with decline of endothelial cell viability after seven days. Using finite volume CFD simulations of different sized molecules vital for pre-vascular network formation into and out of the hydrogel constructs, we found that interstitial flow enhances growth factor supply to the cells in the bulk of the chamber but elutes cellular secretome, resulting in truncated, premature vascularization.

21 March 2019 in Evidence-Based Complementary and Alternative Medicine
Verified
Journal Article
Open access
PDF file
NMNorbert Maurer
Norbert Maurer
HNHelmut Nissel
Helmut Nissel
MEMonika Egerbacher
Monika Egerbacher
EGErich Gornik
Erich Gornik
PSPatrick Schuller
Patrick Schuller
HTHannes Traxler
Hannes Traxler
For more than 2500 years, acupuncture has been applied to support the healing of different diseases and physiologic malfunctions. Although various theories of the meridian system and mechanisms were formulated to explain the functional basis of acupuncture, the anatomical basis for the concept of meridians has not been resolved. The aim of the present study was to search for replicable anatomical structures that could relate to meridians. To this end, four human specimens and additionally two lower legs were dissected anatomically. Our study found evidence that acupuncture meridians were part of the human extracellular matrix and that fascia was an important part of the anatomic substrate of acupuncture meridians. At the same time, we found vessel-nerve-bundles, which were hypothesized to account for 80% of acupuncture points, only in a few acupuncture points. Therefore, our findings contradict the theory that acupuncture points are only located along the nervous channels.