Shuchan He

Shuchan He

Auto-generated profile, based on publicly available information

Shuchan He

School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 May 2024 in IEEE Access
Verified
Journal Article
Open access
SHShuchan He
Shuchan He
XYXiaoming Yuan
Xiaoming Yuan
JHJiabing Hu
Jiabing Hu
HYHui Yang
Hui Yang
With the increasing challenges posed by line-commutated converter-based high-voltage direct current (LCC-HVDC) in the era of widespread renewable energy utilization, AC/DC dynamic interaction problems under controller regulations appeared more often. However traditional approaches often fall short in identifying the features of signals involved in AC/DC conversion in grid dynamics, and the characteristics of the conversion process in the LCC main circuit are overlooked. Consequently, this paper aims to fill this gap to help reveal the mechanism of grid dynamic problems dominated by controller regulations. Based on the recognition that the amplitude/frequency of AC electrical variables has time-varying characteristics in practice during grid dynamics, this paper focuses on the conversion mechanism between AC and DC electrical variables and then the basic features of electrical variables in LCC main circuits during grid dynamics are expressed using time-varying amplitude/frequency rotating vectors. First, the six-pulse firing pattern is expressed using the rotating vector with time-varying frequency. Then the time-varying amplitude/frequency rotating vectors are utilized to discuss how AC/DC voltage and current converse, including the power produced from them during grid dynamics. Moreover, simulations are performed to validate the efficacy of the mechanism, alongside elucidating its potential applications to benefit grid dynamic analysis. Finally, the salient contributions of this proposed framework are clarified.

3 February 2022 in IET Conference Proceedings
Verified
Journal Article
Closed access
JZJ. Zhang
J. Zhang
YHY. Han
Y. Han
XLX. Luo
X. Luo
JDJ. Deng
J. Deng
YMY. Meng
Y. Meng
LLL. Liu
L. Liu
The ZnO arresters in 500kV AC filters in many converter stations have abnormal discharge during operation, which accelerated the aging of arresters and even caused arresters out of work. In this paper, through the disassembly experiment of the whole arresters and the test of the electrical characteristic parameters of the varistors, the failure reason and aging characteristics are preliminarily analyzed. Firstly, it is found that there are obvious cracks and surface discharge traces on one individual varistor of the F1 arrester for AC filter; while disassembling the F2 arrester for AC filter, it is found that the appearance of the porcelain sleeve and the internal va ristors of the arrester are intact. Secondly, The electrical characteristic parameters measurement results show that the electrical characteristic parameters of each varistor of F1 arrester for AC filt er are dispersed, as high as 8%; the DC reference volta ge U1mA and leakage current IL at 0.75 times U1mA of each varistor of F2 arrester for AC filter have obvious polarity effect. Therefore, it is preliminarily inferred that the frequent large impulse current is the main reason of the arresters failure, and p arameters dispersion and polarity effect of the varistors in one arrester are critical influencing factors.