Humoral response to SARS-CoV-2 has been studied, predominantly the classical IgG and its subclasses. Although IgE antibodies are typically specific to allergens or parasites, a few reports describe their production in response to SARS-CoV-2 and other viruses. Here, we investigated IgE specific to receptor binding domain (RBD) of SARS-CoV-2 in a Brazilian cohort following natural infection and vaccination. Samples from 59 volunteers were assessed after infection (COVID-19), primary immunization with vectored (ChAdOx1) or inactivated (CoronaVac) vaccines, and booster immunization with mRNA (BNT162b2) vaccine. Natural COVID-19 induced IgE, but vaccination increased its levels. Subjects vaccinated with two doses of ChAdOx1 exhibited a more robust response than those immunized with two doses of CoronaVac; however, after boosting with BNT162b2, all groups presented similar IgE levels. IgE showed intermediate-to-high avidity, especially after the booster vaccine. We also found IgG4 antibodies, mainly after the booster, and they moderately correlated with IgE. ELISA results were confirmed by control assays, using IgG depletion by protein G and lack of reactivity with heterologous antigen. In our cohort, no clinical data could be associated with the IgE response. We advocate for further research on IgE and its role in viral immunity, extending beyond allergies and parasitic infections.
1 January 2014 in Jornal Brasileiro de Patologia e Medicina Laboratorial
Introduction: The antibodies have an important role in the serodiagnosis, constituting the most widely used biomarkers to detect and confirm various diseases. Objective: To investigate the reproducibility of anti-human immunodeficiency virus (HIV) antibodies reactivity, to assess the stability of the sera samples stored at -20ºC for two to eighteen years. Method: Sera were collected in the period 1988-2004 for routine anti-HIV antibodies diagnostic testing. The remaining samples stored at -20ºC, were analyzed in this study. Serum sample stability was assessed by enzyme-linked immunosorbent assay/enzyme immunoassay (ELISA/EIA), indirect immunofluorescence assay (IFA), and Western blot (WB) for detecting anti-HIV antibodies. The previously found results (1988-2004) and those obtained in 2006 were subjected to Kappa index analysis. Result: In the period 1988-to 2004, the degree of concordance of the ELISA/EIA, IFA and WB results were considered, good (k = 0.80), regular (k = 0.35), and good (k = 0.63), respectively. Conclusion: Regarding HIV serologic test, the serum samples were stable for 18 years in ELISA/EIA and for 4 years in IFA technique, however, for the WB methodology it was not possible to determine the time of stability of the anti-HIV antibodies
1 January 2021 in Revista do Instituto de Medicina Tropical de São Paulo
Twenty-seven children aged seven months to 5 years were inadvertently vaccinated with a COVID-19 vaccine, the CoronaVac (Sinovac, China), an inactivated SARS-CoV-2 vaccine, in two different cities of Sao Paulo State, Brazil. After the event, these children were monitored by local pediatricians and serum samples were collected at the first visit and 30 days after vaccination and tested for SARS-CoV-2 S1 serology with Ortho total IgG anti-S1 protein and Cpass, an ACE2 receptor binding domain inhibition assay. Only one child had a mild symptom after vaccination, with no other adverse events documented up to the 30 days follow-up. Of 27 children tested 3-9 days after vaccination, 5 (19%) had positive serology suggesting a previous natural SARS-CoV-2 infection, with all 19 tested on day 30 after vaccination and presenting with positive tests, with an increment of antibody titers in those initially positive. A low Cpass binding inhibition was observed in the first collection in 11 seronegative cases, with high titers among those anti-S1 positive. All children showed an important increase in antibody titers on day 30. The event allowed the documentation of a robust serological response to one dose of CoronaVac in this small population of young children, with no major adverse effects. Although it was an unfortunate accident, this event may contribute with future vaccine strategies in this age group. The data suggest that CoronaVac is safe and immunogenic for children.
Practical laboratory proxies that correlate to vaccine efficacy may facilitate trials, identify nonresponders, and inform about boosting strategies. Among clinical and laboratory markers, assays that evaluate antibodies that inhibit receptor‐binding domain (RBD) ligation to angiotensin‐converting enzyme‐2 receptor (receptor‐binding inhibition [RBI]) may provide a surrogate for viral neutralization assays. We evaluated RBI before and after a median of 34 days (interquartile range [IQR]: 33–40) of the second dose of severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2) Sinovac's CoronaVac (CN) or AstraZeneca/Oxford's AZD1222 (AZ) vaccines in 166 individuals. Both vaccines elicited high inhibitory titers in most subjects, 95% (158/166), with signal inhibition above 30% and 89% (127/143) with more than fourfold increase from prevaccination titers, but titers tend to decrease over time. Both postvaccination inhibitory titers (95%, IQR 85%–97% for AZ vs. 79%, IQR 60%–96% for CN, p = 0.004) and pre/post‐titer increase (AZ 76%, IQR 51%–86% for AZ vs. 47%, IQR 24%–67% for CN, p < 0.0001) were higher among AZ vaccinees. Previous serological reactivity due to natural infection was associated with high prevaccination signal inhibition titers. The study documents a robust antibody response capable of interfering with RBD–angiotensin‐converting enzyme binding. Evaluation of SARS‐CoV‐2 infection incidence in these populations is necessary to assess its association to protection and its duration.
1 January 2020 in Jornal Brasileiro de Patologia e Medicina Laboratorial
O Instituto Adolfo Lutz (IAL) foi criado em 1940 como resultado da unificação dos Institutos Bacteriológico e Bromatológico, um moderno laboratório voltado ao controle de doenças, inaugurando uma nova fase de Laboratórios de Saúde Pública no estado de São Paulo. Os primeiros testes sorológicos oferecidos à população foram executados pelas “antigas” Seções de Sorologia e de Imunologia. Destaca-se a importância dessas seções no desenvolvimento científico do IAL pela realização de pesquisas, produção científica e inovação tecnológica, seguramente, fundamentais para a saúde pública no decorrer dos anos. O Centro de Imunologia do IAL (CIM-IAL) foi criado em 2010, com a unificação das Seções de Sorologia e Imunologia, quando ocorreu a reorganização institucional. O CIM-IAL participou de importantes avanços científicos na área da saúde, reforçando sua capacidade em desenvolver pesquisas, executar e monitorar o diagnóstico e a vigilância de diferentes agravos. Este manuscrito tem como objetivo apresentar os principais acontecimentos que ressaltam o papel fundamental na busca de soluções para os problemas de saúde pública, desde a época das Seções de Sorologia e Imunologia até tornar-se o Centro de Imunologia. Na elaboração deste trabalho foram utilizadas bibliografias contendo dados históricos, científicos e relatos de profissionais da área.