Robert D. Shull
Materials Science and Engineering Division, Material Measurement Laboratory, National Institute of Standards and Technology (NIST), Gaithersburg, MD, USA
We report here on the reproducibility of measurements on a second-order gradiometer superconducting quantum interference device magnetometer of two different yttrium iron garnet spheres, both having a diameter of 1 mm: 1) the National Institute of Standards and Technology magnetic moment standard reference material (SRM) and 2) a commercial sample. It has been suggested that rotating the sample rod around its axis can move the sample center toward the center of the second-order gradiometer coil. The observed value of the magnetic moment will be theoretically a minimum when the radial offset is 0, and this value will increase in a “quadratic” manner with the radial offset. When the magnetic moment of the SRM was repeatedly measured as a function of rotation angle φ from 0° to 360°, we observed a sinusoidal variation in the measured values. The radial offset dependence of the observed magnetic moment was experimentally confirmed by the measurements of the commercial sphere placed in a hole in several cylindrical containers, wherein the distance between the center of the hole and the center of the container was r. The r-dependence of the minimum from each φ-dependent measurement series is qualitatively consistent with the theoretical curve. When the φ-dependent measurements for the SRM in a capsule were repeated 12× over 21 months, the relative standard deviation of the minimums improved up to 0.1%. Knowledge of these facts will be necessary for the accurate measurement of the magnetic moment of other sample forms (e.g., powders).
We report here on sample length dependence measurements in a second-order gradiometer superconducting quantum interference device (SQUID) magnetometer of pure nickel (Ni) cylinders, having a diameter of 1 mm and length of 1 mm to 7 mm. The measured magnetic moment per unit mass significantly decreases with the sample length of the Ni cylinder, when a magnetic field of 7 T was applied parallel to the long axis of the cylinder. As an example, the magnetic moment per unit mass for the 5 mm Ni cylinder is between 97 % and 94% of that for the 1 mm Ni cylinder, the number depending on the specific type of magnetometer used. The magnitude of decrease also depends on the length of the second-order gradiometer superconducting coil which differs with different models of SQUID magnetometers.
New features of the magnetization reversal of a patterned bilayer in the form of a square mesh consisting of 16 μm wide intersecting stripes of Ni 79 Fe 21 (30 nm) exchange-coupled with IrMn (10 nm) on top were revealed via use of the advanced magneto-optical indicator film technique. A peculiar asymmetry of the remagnetization behavior was observed for the forward and backward branches of the hysteresis loop for fields parallel to the sample's unidirectional anisotropy. Herein, we compare the magnetization reversal processes in the biased and nonbiased patterned ferromagnetic nano-layers.
21 December 2016 in IEEE Transactions on Magnetics
During the past 25 years since the first International Conference on Fine Particle Magnetism (ICFPM), held in Rome in 1991, there have been many developments in the methods for preparing fine particles, for characterizing them, and for implementing them in various applications. In 1991, research was focused on relaxation phenomena, spin glasses, remanence curves, and quantum tunneling. In 2016, the focus was on Néel vs. Brownian relaxation, “super” spin glasses, first order reversal curve analyses, functionalization of nanoparticles, biological applications, and implementation of fine magnetic particles in spintronic devices.