Reliable condition indicators are necessary to perform effective diagnosis and prognosis. However, the vibration signals are often corrupted with non-Gaussian noise and rotating machines may operate under time-varying operating conditions. This impedes the application of conventional condition indicators. The synchronous average of the squared envelope is a relatively simple yet effective method to perform fault detection, fault identification and fault trending under constant and time-varying operating conditions. However, its performance is impeded by the presence of impulsive signal components attributed to impulsive noise or the presence of other damage modes in the machine. In this work, it is proposed that the synchronous median of the squared envelope should be used instead of the synchronous average of the squared envelope for gearbox fault diagnosis. It is shown on numerical and experimental datasets that the synchronous median is more robust to the presence of impulsive signal components and is therefore more reliable for estimating the condition of specific machine components.
Moisture accumulation and life span in a hydric setting are major concerns for natural fibers used for the reinforcement of bio-based composites. This article discusses the effect of water aging on the mechanical properties of poly-lactic acid composites reinforced with flax fibers produced by 3D printing. Water absorption of composites is measured and it was observed that the bio-based composite seems to be Fick’s model with a percentage of absorption at saturation equal to 1.2%. To determine the effect of water absorption on static and vibration mechanical properties, various immersion periods are chosen. Water aging obviously influences the stiffness and tensile failure; so, a decline in the Young’s modulus from 2.2 to 1.7 GPa and in strength from 36 to 30.5 MPa is seen. Nevertheless, the damping factor shows an increase by about 16% as a function of the immersion period. These results could be explained by the plasticizing effect of water on bio-based composites, stimulated by moisture absorption.
The non-linear dynamic behaviour of a single stage spur gear reducer is investigated in transient regime. The gear pair excitation is the result of motor torque variation and the fluctuation of meshing stiffness. The non-linearity is induced by the Hertzian contact force between teeth. Tooth crack and breakage are also modelled. The equations of motion of the transmission are solved iteratively using implicit type numerical integration technique Newmark-β with Newton-Raphson method. The numerical simulation results are analysed in time and frequencies fields. These results confirm the influence of the Hertzian stiffness on the dynamic behaviour of the system especially in the transient regime. Tooth defects contribute to the aggravation of the vibration levels.