Luis David Rosales-Vazquez

Luis David Rosales-Vazquez

Auto-generated profile, based on publicly available information

Luis David Rosales-Vazquez

Instituto de Química Universidad Nacional Autónoma de México Circuito Exterior, Ciudad Universitaria México 04510, CDMX. México

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 March 2021 in Dalton Transactions
Verified
Journal Article
Closed access
PDF file
LRLuis D. Rosales-Vázquez
Luis D. Rosales-Vázquez
ADAlejandro Dorazco-González
Alejandro Dorazco-González
VSVictor Sanchez-Mendieta
Victor Sanchez-Mendieta
Photoluminescent chemosensors based on Zn and Cd coordination arrays for the sensitive and selective detection of pesticides, herbicides, and cyanide in aqueous environments.

28 June 2019 in Dalton Transactions
Verified
Journal Article
Closed access
PDF file
LRLuis D. Rosales-Vázquez
Luis D. Rosales-Vázquez
JVJosue Valdes-García
Josue Valdes-García
IBIván J. Bazany-Rodríguez
Iván J. Bazany-Rodríguez
Juan Manuel Germán-AcacioJuan Manuel Germán-Acacio
Juan Manuel Germán-Acacio
DMDiego Martínez-Otero
Diego Martínez-Otero
ADAlejandro Dorazco-González
Alejandro Dorazco-González
Sensitive and direct sensing of cyanide in buffered aqueous solutions at pH = 7.0 by three new blue photoluminescent zinc-1,4-cyclohexanedicarboxylato coordination polymers bearing di-alkyl-2,2′-bipyridines has been achieved. Specifically, a Zn-polymer with the general formula: {[Zn2(H2O)2(e,a-cis-1,4-chdc)2(4,4′-dtbb)2]·7H2O}n, (1,4-chdc = 1,4-cyclohexanedicarboxylato and 4,4′-dtbb = 4,4′-ditert-butyl-2,2′-bipyridine) has been synthesized in high yield and studied as a luminescent chemosensor for halides, pseudohalides and a series of oxyanions in neutral water. CN− ions can be quantitatively detected by this polymer based on complete quenching (λem = 434 nm) in the sub-micromolar concentration range with a pronounced selectivity over common anions such as acetate, bromide and iodide. The quenching response (KSV = 9.7(±0.2) × 104 M−1) by the addition of CN− was also observed in the presence of typical interfering anions with a very low detection limit of 0.9 μmol L−1 in buffered water at pH = 7.0. On the basis of the crystal structure and solid state CPMAS 13C-NMR correlation and 1H NMR, IR-ATR, MS-ESI(+) and SEM-EDS experiments, the optical change is attributed to the efficient release of its corresponding ditert-butyl-bipyridine, with the simultaneous formation of a zinc cyanide complex. The CPMAS 13C-NMR spectrum of the coordination polymer is consistent with the symmetry of the crystal structure. The use of flexible coordination polymers as fluorescent sensors for fast and selective detection of cyanide ions in pure aqueous solutions has been unexplored until now.

15 March 2022 in Journal of Materials Chemistry C
Verified
Journal Article
Closed access
PDF file
LRLuis D. Rosales-Vázquez
Luis D. Rosales-Vázquez
JVJosue Valdes-García
Josue Valdes-García
Juan Manuel Germán-AcacioJuan Manuel Germán-Acacio
Juan Manuel Germán-Acacio
JFJosé Carlos Páez Franco
José Carlos Páez Franco
DMDiego Martínez-Otero
Diego Martínez-Otero
ADAlejandro Dorazco-González
Alejandro Dorazco-González
Atorvastatin is amongst the most worldwide-prescribed drugs for cholesterol-lowering treatment. In this work, a novel water-stable 3D porous metal–organic framework {[Zn3(Htptc)2]·(H2O)1.3·(CH3CH2OH)3.1}n, 1 (H4tptc= terphenyl-3,3′′,5,5′′-tetracarboxylic acid) was synthesized, structurally determined by single-crystal X-ray diffraction, and studied in-depth as a luminescent sensor for a series of statins and common biological ions (oxyanions, dicarboxylates, citrate, and adenosine 5′-triphosphate) in 20% aqueous ethanol. The luminescence of 1 can be effectively quenched by atorvastatin (KSV = 1.40 × 105 M−1) with a pronounced selectivity over other typical statins such as fluvastatin, pravastatin, and rosuvastatin. The efficient quenching response exhibits excellent selectivity even in the presence of coexisting species in blood plasma and urine with a detection limit of 4.2 μmol L−1. On the basis of multiple spectroscopic tools (fluorescence, UV-Vis, powder X-ray diffraction, lifetimes), the crystal structure of 1, SEM observations, EDS analysis, and DFT calculations, the sensing mechanism is proposed via a static-complexation PET process driven through π-stacking interactions between π-electron-rich terphenyl ligand and two aromatic rings from the atorvastatin. Neutral aqueous-phase dispersions of 1 allow for the detection of atorvastatin in real pharmaceutical samples. The utilization of MOFs-based materials as luminescent sensors for selective and sensitive detection of atorvastatin has not been explored till now.

4 August 2020 in Chemistry – An Asian Journal
Verified
Journal Article
Closed access
PDF file
JVJosue Valdes-García
Josue Valdes-García
LRLuis D. Rosales‐Vázquez
Luis D. Rosales‐Vázquez
IBIván J. Bazany‐Rodríguez
Iván J. Bazany‐Rodríguez
ADAlejandro Dorazco-González
Alejandro Dorazco-González

22 December 2023 in Environmental Pollution
Verified
Journal Article
Closed access
HJHelen Paola Toledo Jaldin
Helen Paola Toledo Jaldin
CPCristian Pinzón-Vanegas
Cristian Pinzón-Vanegas
ABAlien Blanco-Flores
Alien Blanco-Flores
JZJulio Zamora-Moreno
Julio Zamora-Moreno
LRLuis D. Rosales-Vázquez
Luis D. Rosales-Vázquez
ADAlejandro Dorazco-González
Alejandro Dorazco-González

29 August 2017 in Dalton Transactions
Verified
Journal Article
Closed access
PDF file
LRLuis D. Rosales-Vázquez
Luis D. Rosales-Vázquez
VSVictor Sanchez-Mendieta
Victor Sanchez-Mendieta
ADAlejandro Dorazco-González
Alejandro Dorazco-González
DMDiego Martínez-Otero
Diego Martínez-Otero
IGIván García-Orozco
Iván García-Orozco
ATAntonio Téllez-López
Antonio Téllez-López
Cd(ii) polymers, in acetone, can be used as luminescent materials for detection of CH3CN.