Patrick Kilcullen

Patrick Kilcullen

Auto-generated profile, based on publicly available information

Patrick Kilcullen

Centre Énergie Matériaux Télécommunications, Institut National de la Recherche Scientifique, Université du Québec, Varennes, Canada

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 December 2022 in Nature Communications
Verified
Journal Article
Open access
PDF file
PKPatrick Kilcullen
Patrick Kilcullen
TOTsuneyuki Ozaki
Tsuneyuki Ozaki
JLJinyang Liang
Jinyang Liang
Single-pixel imaging (SPI) has emerged as a powerful technique that uses coded wide-field illumination with sampling by a single-point detector. Most SPI systems are limited by the refresh rates of digital micromirror devices (DMDs) and time-consuming iterations in compressed-sensing (CS)-based reconstruction. Recent efforts in overcoming the speed limit in SPI, such as the use of fast-moving mechanical masks, suffer from low reconfigurability and/or reduced accuracy. To address these challenges, we develop SPI accelerated via swept aggregate patterns (SPI-ASAP) that combines a DMD with laser scanning hardware to achieve pattern projection rates of up to 14.1 MHz and tunable frame sizes of up to 101×103 pixels. Meanwhile, leveraging the structural properties of S-cyclic matrices, a lightweight CS reconstruction algorithm, fully compatible with parallel computing, is developed for real-time video streaming at 100 frames per second (fps). SPI-ASAP allows reconfigurable imaging in both transmission and reflection modes, dynamic imaging under strong ambient light, and offline ultrahigh-speed imaging at speeds of up to 12,000 fps.

30 October 2020 in Photonics Research
Verified
Journal Article
Closed access
CJCheng Jiang
Cheng Jiang
PKPatrick Kilcullen
Patrick Kilcullen
YLYingming Lai
Yingming Lai
TOTsuneyuki Ozaki
Tsuneyuki Ozaki
JLJinyang Liang
Jinyang Liang
We report dual-view band-limited illumination profilometry (BLIP) with temporally interlaced acquisition (TIA) for high-speed, three-dimensional (3D) imaging. Band-limited illumination based on a digital micromirror device enables sinusoidal fringe projection at up to 4.8 kHz. The fringe patterns are captured alternately by two high-speed cameras. A new algorithm, which robustly matches pixels in acquired images, recovers the object’s 3D shape. The resultant TIA–BLIP system enables 3D imaging over 1000 frames per second on a field of view (FOV) of up to 180 mm × 130 mm (corresponding to 1180 × 860    pixels ) in captured images. We demonstrated TIA–BLIP’s performance by imaging various static and fast-moving 3D objects. TIA–BLIP was applied to imaging glass vibration induced by sound and glass breakage by a hammer. Compared to existing methods in multiview phase-shifting fringe projection profilometry, TIA–BLIP eliminates information redundancy in data acquisition, which improves the 3D imaging speed and the FOV. We envision TIA–BLIP to be broadly implemented in diverse scientific studies and industrial applications.

14 September 2023 in Optica
Verified
Journal Article
Closed access
XLXianglei Liu
Xianglei Liu
PKPatrick Kilcullen
Patrick Kilcullen
YWYoumin Wang
Youmin Wang
BHBrandon Helfield
Brandon Helfield
JLJinyang Liang
Jinyang Liang
Single-shot high-speed mapping photography is a powerful tool used for studying fast dynamics in diverse applications. Despite much recent progress, existing methods are still strained by the trade-off between sequence depth and light throughput, errors induced by parallax, limited imaging dimensionality, and the potential damage caused by pulsed illumination. To overcome these limitations, we explore time-varying optical diffraction as a new gating mechanism to obtain ultrahigh imaging speed. Inspired by the pulse front tilt-gated imaging and the space-time duality in optics, we embody the proposed paradigm in the developed diffraction-gated real-time ultrahigh-speed mapping (DRUM) photography. The sweeping optical diffraction envelope generated by the inter-pattern transition of a digital micromirror device enables sequential time-gating at the sub-microsecond level. DRUM photography can capture a transient event in a single exposure at 4.8 million frames per second. We apply it to the investigation of femtosecond laser-induced breakdown in liquid and laser ablation in biological samples.

17 September 2020 in Optics Express
Verified
Journal Article
Closed access
PKPatrick Kilcullen
Patrick Kilcullen
CJCheng Jiang
Cheng Jiang
TOTsuneyuki Ozaki
Tsuneyuki Ozaki
JLJinyang Liang
Jinyang Liang
We report camera-free three-dimensional (3D) dual photography. Inspired by the linkage between fringe projection profilometry (FPP) and dual photography, we propose to implement coordinate mapping to simultaneously sense the direct component of the light transport matrix and the surface profiles of 3D objects. By exploiting Helmholtz reciprocity, dual photography and scene relighting can thus be performed on 3D images. To verify the proposed imaging method, we have developed a single-pixel imaging system based on two digital micromirror devices (DMDs). Binary cyclic S-matrix patterns and binary sinusoidal fringe patterns are loaded on each DMD for scene encoding and virtual fringe projection, respectively. Using this system, we have demonstrated viewing and relighting 3D images at user-selectable perspectives. Our work extends the conceptual scope and the imaging capability of dual photography.

6 October 2025 in Nature Communications
Verified
Journal Article
Open access
PDF file
CJCheng Jiang
Cheng Jiang
PKPatrick Kilcullen
Patrick Kilcullen
YLYingming Lai
Yingming Lai
TOTsuneyuki Ozaki
Tsuneyuki Ozaki
JLJinyang Liang
Jinyang Liang
Efficiently and accurately mapping the temperature of human inner canthi is crucial for disease diagnostics and monitoring. The specific anatomical location of the inner canthi precludes temperature screening methods that are invasive, require tissue contact, and/or demand active illumination. Camera-based thermography, although capable of passive and non-contact temperature mapping, suffers from low efficiency in pixel allocation to the inner canthi as well as from measurement inaccuracies due to background blending and moderate pixel sensitivity. In response to these challenges, we develop single-pixel infrared imaging thermometry (SPIRIT). We design diagonally aggregated two-dimensional transmissive encoding masks using a cyclic S-matrix, which supports compressed data acquisition in a single scan and high image quality through non-iterative reconstruction. SPIRIT maps the temperature distribution of human inner canthi with a resolution of 0.3 °C, which enables human temperature mapping via single-pixel imaging. Using SPIRIT, we reveal sub-degree temperature differences induced by daily physical activities and the glasses-wearing habit. These findings shed light on SPIRIT’s contribution to improving evaluation criteria for public health, including COVID-19 febrile screening.

16 January 2015 in Journal of Infrared, Millimeter, and Terahertz Waves
Verified
Journal Article
Closed access
PDF file
PKPatrick Kilcullen
Patrick Kilcullen
IHI. D. Hartley
I. D. Hartley
EJE. T. Jensen
E. T. Jensen
MRM. Reid
M. Reid