Jian Shi

Jian Shi

Auto-generated profile, based on publicly available information

Jian Shi

PASTEUR, Département de chimie, École normale supérieure, PSL University, Sorbonne Université, CNRS, 75005 Paris, France

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 March 2016 in Journal of the American Chemical Society
Verified
Journal Article
Closed access
VBVitor Brasiliense
Vitor Brasiliense
APAnisha N. Patel
Anisha N. Patel
AMAriadna Martinez-Marrades
Ariadna Martinez-Marrades
JSJian Shi
Jian Shi
YCYong Chen
Yong Chen
FKFrédéric Kanoufi
Frédéric Kanoufi

13 August 2014 in Scientific Reports
Verified
Journal Article
Open access
PDF file
YTYadong Tang
Yadong Tang
JSJian Shi
Jian Shi
SLSisi Li
Sisi Li
LWLi Wang
Li Wang
YCYvon E. Cayre
Yvon E. Cayre
YCYong Chen
Yong Chen
Capture of circulating tumor cells (CTCs) from peripheral blood of cancer patients has major implications for metastatic detection and therapy analyses. Here we demonstrated a microfluidic device for high efficiency and high purity capture of CTCs. The key novelty of this approach lies on the integration of a microfilter with conical-shaped holes and a micro-injector with cross-flow components for size dependent capture of tumor cells without significant retention of non-tumor cells. Under conditions of constant flow rate, tumor cells spiked into phosphate buffered saline could be recovered and then cultured for further analyses. When tumor cells were spiked in blood of healthy donors, they could also be recovered at high efficiency and high clearance efficiency of white blood cells. When the same device was used for clinical validation, CTCs could be detected in blood samples of cancer patients but not in that of healthy donors. Finally, the capture efficiency of tumor cells is cell-type dependent but the hole size of the filter should be more closely correlated to the nuclei size of the tumor cells. Together with the advantage of easy operation, low-cost and high potential of integration, this approach offers unprecedented opportunities for metastatic detection and cancer treatment monitoring.

20 April 2011 in Nanotechnology
Verified
Journal Article
Closed access
JTJing-Hua Tian
Jing-Hua Tian
JHJie Hu
Jie Hu
SLSi-Si Li
Si-Si Li
FZFan Zhang
Fan Zhang
JLJun Liu
Jun Liu
YCYong Chen
Yong Chen
Seedless hydrothermal synthesis has been improved by introducing an adequate content of ammonia into the nutrient solution, allowing the fabrication of dense and ultralong ZnO nanowire arrays over large areas on a substrate. The presence of ammonia in the nutrient solution facilitates the high density nucleation of ZnO on the substrate which is critical for the nanowire growth. In order to achieve an optimal growth, the growth conditions have been studied systematically as a function of ammonia content, growth temperature and incubation time. The effect of polyethyleneimine (PEI) has also been studied but shown to be of no benefit to the nucleation of ZnO. Ultradense and ultralong ZnO nanowires could be obtained under optimal growth conditions, showing no fused structure at the foot of the nanowire arrays. Due to different reaction kinetics, four growth regimes could be attributed, including the first fast growth, equilibrium phase, second fast growth and final erosion. Combining this simple method with optical lithography, ZnO nanowires could be grown selectively on patterned areas. In addition, the as-grown ZnO nanowires could be used for the fabrication of a piezoelectric nanogenerator. Compared to the device of ZnO nanowires made by other methods, a more than twice voltage output has been obtained, thereby proving an improved performance of our growth method.

11 March 2010 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
JSJian Shi
Jian Shi
LWLi Wang
Li Wang
FZFan Zhang
Fan Zhang
HLHao Li
Hao Li
LLLei Lei
Lei Lei
YCYong Chen
Yong Chen

6 April 2010 in BMC Bioinformatics
Verified
Journal Article
Open access
PDF file
JSJian Shi
Jian Shi
YZYiwei Zhang
Yiwei Zhang
HLHaiwei Luo
Haiwei Luo
JTJijun Tang
Jijun Tang
In recent years, gene order data has attracted increasing attention from both biologists and computer scientists as a new type of data for phylogenetic analysis. If gene orders are viewed as one character with a large number of states, traditional bootstrap procedures cannot be applied. Researchers began to use a jackknife resampling method to assess the quality of gene order phylogenies.

3 July 2019 in Biofabrication
Verified
Journal Article
Closed access
PDF file
BWBin Wang
Bin Wang
JSJian Shi
Jian Shi
JWJin Wei
Jin Wei
XTXiaolong Tu
Xiaolong Tu
YCYong Chen
Yong Chen
The elasticity of the cell and that of the supporting extracellular matrices (ECMs) in tissue are correlated. In some cases, the modulus of the ECM varies with a high spatial gradient. To study the effect of such a modulus gradient on the cell culture behavior, we proposed a novel yet straightforward method to fabricate elastomeric micropillar substrates with different height gradients, which could provide a large range of elasticity gradient from 2.4 kPa to 60 kPa. The micropillars were integrated into a microfluidic chip to demonstrate the elasticity variation, with the theoretical results proving that the elasticity of the two micropillar substrates was in the same range but with distinguished gradient strengths. Fibroblast seeded on the micropillar substrates showed migration toward the stiffer area but their elongation highly depended on the strength of the elasticity gradient. In the case of high gradient strength, cells could easily migrate to the stiffer area and then elongated perpendicularly to their migration direction. Otherwise, cells were mostly elongated in the direction of the gradient. Our results also showed that when the cell density was sufficiently high, cells tended to be oriented in the same direction locally, which was affected by both underneath pillars and cell–cell contact. The elasticity gradients could also be generated in a ripple shape, and the cell behavior showed the feasibility of using the micropillars for cell patterning applications. Moreover, the gradient pillar substrates were further used for the aggregate formation of induced pluripotent stem cells, thus providing an alternative substrate to study the effect of substrate elasticity on stem cell behavior and differentiation.