Jonathan Sittner

Jonathan Sittner

Auto-generated profile, based on publicly available information

Jonathan Sittner

Bundesanstalt für Materialforschung und -prüfung (BAM)

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 October 2020 in X-Ray Spectrometry
Verified
Journal Article
Open access
PDF file
JSJonathan Sittner
Jonathan Sittner
JGJose R. A. Godinho
Jose R. A. Godinho
ARAxel D. Renno
Axel D. Renno
Veerle CnuddeVeerle Cnudde
Veerle Cnudde
MBMarijn Boone
Marijn Boone
JLJussi Liipo
Jussi Liipo
We present a new approach to 3‐dimensional chemical imaging based on X‐ray computed micro tomography (CT), which enables the analysis of the internal elemental chemistry. The method uses a conventional laboratory‐based CT scanner equipped with a semiconductor detector (CdTe). Based on the X‐ray absorption spectra, elements in a sample can be distinguished by their specific K‐edge energy. The capabilities and performance of this new approach are illustrated with different experiments, i.e. single pure element particle measurements, element differentiation in mixtures, and mineral differentiation in a natural rock sample. The results show that the method can distinguish elements with K‐edges in the range of 20 to 160 keV, this corresponds to an element range from Ag to U. Furthermore, the spectral information allows a distinction between materials, which show little variation in contrast in the reconstructed CT image.

22 June 2023 in Minerals Engineering
Verified
Journal Article
Closed access
Asim SiddiqueAsim Siddique
Asim Siddique
JGJose R.A. Godinho
Jose R.A. Godinho
JSJonathan Sittner
Jonathan Sittner
LPLucas Pereira
Lucas Pereira

23 March 2022 in Frontiers in Earth Science
Verified
Journal Article
Open access
JSJ. Sittner
J. Sittner
VBV. Brovchenko
V. Brovchenko
Asim SiddiqueAsim Siddique
Asim Siddique
FBF. Buyse
F. Buyse
MBM. Boone
M. Boone
SSS.F. Sluzhenikin
S.F. Sluzhenikin
The Mt. Rudnaya MSS-ISS (monosulfide and intermediate solid solution) fine-grained ores from a NE termination of Norilsk 1 deposit were analyzed using a combination of X-ray computed micro tomography, spectral X-ray computed micro tomography and scanning electron microscopy to achieve both, 2D and 3D data. The ores consist of ISS composed of tiny lamellar intergrowths of cubanite and chalcopyrite solid solutions, which form up to 4-mm distinct globules surrounded by an ISS-MSS matrix. Our X-ray computed micro tomography results may provide 3D textural evidence of a possible natural sulfide-sulfide liquid immiscibility between Cu-rich and Cu-poor sulfide liquids that occurred before MSS and ISS were crystallized. The platinum group minerals (PGM) distribution shows that 20.6 vol% of all PGM occur in the ISS-MSS matrix and 79.4 vol% in the ISS globules. We suggest that this distributional behavior is due to the fact that the platinum group elements (PGE) cannot be dissolved in ISS, which led to the formation of the large PGM grains, which are up to 120 μm on their longest axis. The initial enrichment of ISS in PGE was controlled by differences in the partition coefficients of platinum and palladium between Cu-poor and Cu-rich liquids.

4 March 2021
Verified
Other
Open access
JSJonathan Sittner
Jonathan Sittner
MMMargarita Merkulova
Margarita Merkulova
JGJose Ricardo da Assuncao Godinho
Jose Ricardo da Assuncao Godinho
ARAxel Renno
Axel Renno
Veerle CnuddeVeerle Cnudde
Veerle Cnudde
SDStijn Dewaele
Stijn Dewaele
Image-based analytical tools in geosciences are indispensable for the characterization of minerals, but most of them are limited to the surface of a polished plane in a sample and lack 3D information. X-ray micro computed tomography (micro CT) provides the missing 3D information of the microstructures inside samples. However, a major drawback of micro CT in the characterization of minerals is the lack of chemical information that makes mineral classification challenging.Spectral X-ray micro computed tomography (Sp-CT) is a new and evolving tool in different applications such as medicine, security, material science, and geology. This non-destructive method uses a multi-pixel photon-counting detector (PCD) such as cadmium telluride (CdTe) in combination with a conventional CT scanner (TESCAN CoreTOM) to image a sample and detect its transmitted polychromatic X-ray spectrum. Based on the spectrum, elements in a sample can be identified by an increase in attenuation at specific K-edge energies. Therefore, chemically different particles can be distinguished inside a sample from a single CT scan. The method is able to distinguish elements with K-edges in the range from 25 to 160 keV, which applies to elements with Z > 48 (Sittner et al., 2020).We present results from various sample materials. Different pure elements and element oxides were measured to compare the position of theoretical and measured K-edge energies. All measured K-edge energies are slightly above the theoretical value, but based on the results a correction algorithm could be developed. Furthermore, different monazite grains were investigated, which can be divided into two groups with respect to the content of different RE elements on the basis of the spectrum: La-Ce-rich and La-Ce-poor. In addition, samples from the Au-U Witwatersrand Supergroup demonstrate the potential applications of Sp-CT for geological samples. We measured different drill core samples from the Kalkoenkrans Reef at the Welkom Gold field. Sp-CT can distinguish gold, uraninite and galena grains based on their K-edge energies in the drill core without preparation.Sittner, J., Godinho, J. R. A., Renno, A. D., Cnudde, V., Boone, M., De Schryver, T., Van Loo, D., Merkulova, M., Roine, A., & Liipo, J. (2020). Spectral X-ray computed micro tomography: 3-dimensional chemical imaging. X-Ray Spectrometry, September, 1–14.

13 January 2026
Verified
Book Chapter
Closed access
PDF file
JSJonathan Sittner
Jonathan Sittner
THTorsten Hoffmann
Torsten Hoffmann
MBMarko Bertmer
Marko Bertmer
MNMarkus Neubert
Markus Neubert
TSThomas Schuster
Thomas Schuster
GGGregor J. G. Gluth
Gregor J. G. Gluth