Lars Aabakken

Lars Aabakken

Auto-generated profile, based on publicly available information

Lars Aabakken

Univ. of Oslo

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 December 2007 in Endoscopy
Verified
Journal Article
Closed access
PDF file
LAL. Aabakken
L. Aabakken
MBM. Bretthauer
M. Bretthauer
PLPål‐Dag Line
Pål‐Dag Line
Background and study aims: Double-balloon enteroscopy (DBE) has been proved to be effective for deep intubation of the small bowel. Patients with a Roux-en-Y enteroanastomosis and biliary problems have been a challenge in gastrointestinal practice because of the lack of endoscopic access to the biliary anastomosis. We report on the first case series of patients with Roux-en-Y anatomy who have been examined using DBE. Patients and methods: Between September 2005 and May 2006, 18 endoscopic retrograde cholangiography procedures were performed in 13 patients (median age 53, range 2 - 81 years) using the DBE technique at our hospital. Most of the cases (10/13) had had a liver transplant for primary sclerosing cholangitis. The Fujinon T-series DBE system was used in all cases. Results: The entero-enteric anastomosis was reached easily in all 18 procedures, and the end of the Roux limb was reached in 17/18 procedures. The mean intubation time was 40 minutes (range 5 - 120 minutes). Adequate imaging was achieved in all but two cases, one of whom had a native papilla. Biliary stenting was performed in two patients, stent removal in three patients, and removal of a small stone in one patient. Conclusions: Endoscopic access and biliary cannulation in the setting of Roux-en-Y anatomy is safe and feasible using the new DBE system for enteral intubation. Adaptation of accessories would further improve the utility of the procedure.

1 April 2019 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
HQHemin Ali Qadir
Hemin Ali Qadir
IBIlangko Balasingham
Ilangko Balasingham
JSJohannes Solhusvik
Johannes Solhusvik
JBJacob Bergsland
Jacob Bergsland
LALars Aabakken
Lars Aabakken
YSYounghak Shin
Younghak Shin
Automatic polyp detection has been shown to be difficult due to various polyp-like structures in the colon and high interclass variations in polyp size, color, shape and texture. An efficient method should not only have a high correct detection rate (high sensitivity) but also a low false detection rate (high precision and specificity). The state-of-the-art detection methods include convolutional neural networks (CNN). However, CNNs have shown to be vulnerable to small perturbations and noise; they sometimes miss the same polyp appearing in neighboring frames and produce a high number of false positives. We aim to tackle this problem and improve the overall performance of the CNN-based object detectors for polyp detection in colonoscopy videos. Our method consists of two stages: a region of interest (RoI) proposal by CNNbased object detector networks and a false positive (FP) reduction unit. The FP reduction unit exploits the temporal dependencies among image frames in video by integrating the bidirectional temporal information obtained by RoIs in a set of consecutive frames. This information is used to make the final decision. The experimental results show that the bidirectional temporal information has been helpful in estimating polyp positions and accurately predict the FPs. This provides an overall performance improvement in terms of sensitivity, precision and specificity compared to conventional false positive learning method, and thus achieves the state of the art results on the CVC-ClinicVideoDB video dataset.

10 August 2009 in Endoscopy
Verified
Journal Article
Closed access
PDF file
LALars Aabakken
Lars Aabakken
BRBjorn Rembacken
Bjorn Rembacken
OLOlivier LeMoine
Olivier LeMoine
KKKonstantin Kuznetsov
Konstantin Kuznetsov
JRJean-Francois Rey
Jean-Francois Rey
MFMasayuki Fujino
Masayuki Fujino
Standardization of the language of gastrointestinal endoscopy is becoming increasingly important on account of international collaboration, standardized documentation requirements, and computer-based reporting. Version 1 of the Minimal Standard Terminology (MST) was devised to facilitate this development, and, through broad international collaboration, the document was developed and tested further to produce version 2.0, published in 2000. The document forms the basis for computer software by offering standard minimal lists of terms to be used in the structured documentation of endoscopic findings. The ownership of the MST has been transferred to the World Organisation of Digestive Endoscopy (OMED) and in this context, a new revision of the MST document is now in place. Version 3.0 of the terminology includes terms for endoscopic ultrasound (EUS) and enteroscopy, as well as for adverse event reporting. In addition, acknowledged scoring systems have been included for specific findings, and some structural enhancements have been implemented. The entire document is freely available for noncommercial use from www.omed.org.

13 December 2013 in Journal of Gastroenterology and Hepatology
Verified
Journal Article
Closed access
PDF file
LALars Aabakken
Lars Aabakken
ABAlan N Barkun
Alan N Barkun
PCPeter B Cotton
Peter B Cotton
EFEvgeny Fedorov
Evgeny Fedorov
MFMasayuki A Fujino
Masayuki A Fujino
JWJerome D Waye
Jerome D Waye

30 August 2016 in BMC Research Notes
Verified
Journal Article
Open access
PDF file
NAN. A. Adu-Aryee
N. A. Adu-Aryee
LAL. Aabakken
L. Aabakken
FDF. Dedey
F. Dedey
JNJ. Nsaful
J. Nsaful
WKW. Kudzi
W. Kudzi
Helicobacter pylori is an important risk factor for gastritis, peptic ulcers and gastric cancer. The prevalence in developed countries is lower than 40 % but higher than 80 % in some developing countries. It is 75 % in Ghana. The Helicobacter urease test (HUT) is performed at endoscopy and gives an accurate diagnosis. The HUT is not routinely done at our facility and presumption of H. pylori is made based on endoscopic findings and H. pylori eradication prescribed, as the incidence in the general population is presumed high. Is this endoscopic diagnosis sufficient for diagnosing and treating H. pylori? We aimed to assess the feasibility of an endoscopic based H. pylori diagnosis and its accuracy using a HUT as the gold standard in consecutive patients. Seventy-six consecutive adult patients with dyspepsia were assessed by upper gastrointestinal endoscopy. A clinical diagnosis of H. pylori or not was made. Biopsy samples were collected for HUT. H. pylori was diagnosed if HUT was positive. The results were then compared. Median age of patients was 45.0 years. H. pylori prevalence detected by HUT was 51.3 % (95 % CI 40.0–63.0). Sensitivity of endoscopic diagnosis of H. pylori was 71.8 % (95 % CI 55.1–85.0) and specificity was 37.8 % (95 % CI 22.5–55.2). There was no association between clinical findings (73.7 %) and HUT (26.3 %) (OR = 0.80; [95 % CI 0.24–2.64], p = 0.682). There was also no association between endoscopic diagnosis (71.8 %) and HUT (28.2 %), (OR = 1.55; 95 % CI 0.59–4.06, p = 0.373). Helicobacter pylori infection was not as high as that published in earlier reports. The endoscopic diagnosis alone is not sufficient to make a diagnosis of H. pylori.

1 April 2008 in Best Practice & Research Clinical Gastroenterology
Verified
Journal Article
Closed access
LALars Aabakken
Lars Aabakken