Younghak Shin

Prof. Younghak Shin

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 July 2018 in IEEE Access
Verified
Journal Article
Open access
YSYounghak Shin
Younghak Shin
HQHemin Ali Qadir
Hemin Ali Qadir
LALars Aabakken
Lars Aabakken
JBJacob Bergsland
Jacob Bergsland
IBIlangko Balasingham
Ilangko Balasingham
Automatic image detection of colonic polyps is still an unsolved problem due to the large variation of polyps in terms of shape, texture, size, and color, and the existence of various polyp-like mimics during colonoscopy. In this paper, we apply a recent region-based convolutional neural network (CNN) approach for the automatic detection of polyps in the images and videos obtained from colonoscopy examinations. We use a deep-CNN model (Inception Resnet) as a transfer learning scheme in the detection system. To overcome the polyp detection obstacles and the small number of polyp images, we examine image augmentation strategies for training deep networks. We further propose two efficient post-learning methods, such as automatic false positive learning and offline learning, both of which can be incorporated with the region-based detection system for reliable polyp detection. Using the large size of colonoscopy databases, experimental results demonstrate that the suggested detection systems show better performance than other systems in the literature. Furthermore, we show improved detection performance using the proposed post-learning schemes for colonoscopy videos.

1 October 2018 in IEEE Access
Verified
Journal Article
Open access
YSYounghak Shin
Younghak Shin
HQHemin Ali Qadir
Hemin Ali Qadir
IBIlangko Balasingham
Ilangko Balasingham
One of the major obstacles in automatic polyp detection during colonoscopy is the lack of labeled polyp training images. In this paper, we propose a framework of conditional adversarial networks to increase the number of training samples by generating synthetic polyp images. Using a normal binary form of polyp mask which represents only the polyp position as an input conditioned image, realistic polyp image generation is a difficult task in a generative adversarial networks approach. We propose an edge filtering-based combined input conditioned image to train our proposed networks. This enables realistic polyp image generations while maintaining the original structures of the colonoscopy image frames. More importantly, our proposed framework generates synthetic polyp images from normal colonoscopy images which have the advantage of being relatively easy to obtain. The network architecture is based on the use of multiple dilated convolutions in each encoding part of our generator network to consider large receptive fields and avoid much contractions of a feature map size. An image resizing with convolution for upsampling in the decoding layers is considered to prevent artifacts on generated images. We show that the generated polyp images are not only qualitatively realistic, but also help to improve polyp detection performance.

1 April 2019 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
HQHemin Ali Qadir
Hemin Ali Qadir
IBIlangko Balasingham
Ilangko Balasingham
JSJohannes Solhusvik
Johannes Solhusvik
JBJacob Bergsland
Jacob Bergsland
LALars Aabakken
Lars Aabakken
YSYounghak Shin
Younghak Shin
Automatic polyp detection has been shown to be difficult due to various polyp-like structures in the colon and high interclass variations in polyp size, color, shape and texture. An efficient method should not only have a high correct detection rate (high sensitivity) but also a low false detection rate (high precision and specificity). The state-of-the-art detection methods include convolutional neural networks (CNN). However, CNNs have shown to be vulnerable to small perturbations and noise; they sometimes miss the same polyp appearing in neighboring frames and produce a high number of false positives. We aim to tackle this problem and improve the overall performance of the CNN-based object detectors for polyp detection in colonoscopy videos. Our method consists of two stages: a region of interest (RoI) proposal by CNNbased object detector networks and a false positive (FP) reduction unit. The FP reduction unit exploits the temporal dependencies among image frames in video by integrating the bidirectional temporal information obtained by RoIs in a set of consecutive frames. This information is used to make the final decision. The experimental results show that the bidirectional temporal information has been helpful in estimating polyp positions and accurately predict the FPs. This provides an overall performance improvement in terms of sensitivity, precision and specificity compared to conventional false positive learning method, and thus achieves the state of the art results on the CVC-ClinicVideoDB video dataset.

1 February 2021 in Medical Image Analysis
Verified
Journal Article
Open access
HQHemin Ali Qadir
Hemin Ali Qadir
YSYounghak Shin
Younghak Shin
JSJohannes Solhusvik
Johannes Solhusvik
JBJacob Bergsland
Jacob Bergsland
LALars Aabakken
Lars Aabakken
IBIlangko Balasingham
Ilangko Balasingham
To decrease colon polyp miss-rate during colonoscopy, a real-time detection system with high accuracy is needed. Recently, there have been many efforts to develop models for real-time polyp detection, but work is still required to develop real-time detection algorithms with reliable results. We use single-shot feed-forward fully convolutional neural networks (F-CNN) to develop an accurate real-time polyp detection system. F-CNNs are usually trained on binary masks for object segmentation. We propose the use of 2D Gaussian masks instead of binary masks to enable these models to detect different types of polyps more effectively and efficiently and reduce the number of false positives. The experimental results showed that the proposed 2D Gaussian masks are efficient for detection of flat and small polyps with unclear boundaries between background and polyp parts. The masks make a better training effect to discriminate polyps from the polyp-like false positives. The proposed method achieved state-of-the-art results on two polyp datasets. On the ETIS-LARIB dataset we achieved 86.54% recall, 86.12% precision, and 86.33% F1-score, and on the CVC-ColonDB we achieved 91% recall, 88.35% precision, and F1-score 89.65%.

27 August 2018 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Open access
SLSeungchan Lee
Seungchan Lee
YSYounghak Shin
Younghak Shin
AKAnil Kumar
Anil Kumar
MKMinhee Kim
Minhee Kim
Heung No LeeHeung No Lee
Heung No Lee
A portable hybrid brain monitoring system is proposed to perform simultaneous 16-channel electroencephalogram (EEG) and 8-channel functional near-infrared spectroscopy (fNIRS) measurements. Architecture-optimized analog frontend integrated circuits (Texas Instruments ADS1299 and ADS8688A) were used to simultaneously achieve 24-bit EEG resolution and reliable latency-less (<;0.85 μs) bio-optical measurements. Suppression of the noise and crosstalk generated by the digital circuit components and flashing NIR light sources was maximized through linear regulator-based fully isolated circuit design. Gel-less EEG measurements were enabled by using spring-loaded dry electrodes. Several evaluations were carried out by conducting an EEG phantom test and an arterial occlusion experiment. An alpha rhythm detection test (eye-closing task) and a mental arithmetic experiment (cumulative subtraction task) were conducted to determine whether the system is applicable to human subject studies. The evaluation results show that the proposed system is sufficiently capable of detecting microvoltage EEG signals and hemodynamic responses. The results of the studies on human subjects enabled us to verify that the proposed system is able to detect task-related EEG spectral features such as eye-closed event-related synchronization and mental-arithmetic event-related desynchronization in the alpha and beta rhythm ranges. An analysis of the fNIRS measurements with an arithmetic operation task also revealed a decreasing trend in oxyhemoglobin concentration.

1 November 2018 in Computerized Medical Imaging and Graphics
Verified
Journal Article
Closed access
YSYounghak Shin
Younghak Shin
IBIlangko Balasingham
Ilangko Balasingham