Monika Tomaszuk

Monika Tomaszuk

Auto-generated profile, based on publicly available information

Monika Tomaszuk

Centre of Oncology, Maria Sklodowska-Curie Memorial Institute, Kraków Branch, Garncarska 11, 31-115 Kraków, Poland

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 August 2012
Verified
Book Chapter
Closed access
PDF file
ASAnna Sowa-Staszczak
Anna Sowa-Staszczak
Alicja Hubalewska-DydejczykAlicja Hubalewska-Dydejczyk
Alicja Hubalewska-Dydejczyk
MTMonika Tomaszuk
Monika Tomaszuk

1 July 2012 in Clinical Imaging
Verified
Journal Article
Closed access
ASAnna Sowa-Staszczak
Anna Sowa-Staszczak
RCRobert Chrzan
Robert Chrzan
DPDorota Pach
Dorota Pach
ASAgnieszka Stefańska
Agnieszka Stefańska
MTMonika Tomaszuk
Monika Tomaszuk
AHAlicja Hubalewska-Dydejczyk
Alicja Hubalewska-Dydejczyk

1 January 2011
Verified
Journal Article
Closed access
ASAnna Sowa-Staszczak
Anna Sowa-Staszczak
RPRota Pach
Rota Pach
JKJolanta Kunikowska
Jolanta Kunikowska
LKLeszek Królicki
Leszek Królicki
ASAgnieszka Stefanska
Agnieszka Stefanska
Alicja Hubalewska-DydejczykAlicja Hubalewska-Dydejczyk
Alicja Hubalewska-Dydejczyk

8 February 2013 in Nuclear Medicine Review
Verified
Journal Article
Open access
ASAnna Sowa-Staszczak
Anna Sowa-Staszczak
WLWioletta Lenda-Tracz
Wioletta Lenda-Tracz
MTMonika Tomaszuk
Monika Tomaszuk
BGBogusław Głowa
Bogusław Głowa
AHAlicja Hubalewska-Dydejczyk
Alicja Hubalewska-Dydejczyk
Somatostatin receptor scintigraphy (SRS) is a useful tool in the assessment of GEP-NET (gastroenteropancreatic neuroendocrine tumor) patients. The choice of appropriate settings of image reconstruction parameters is crucial in interpretation of these images. The aim of the study was to investigate how the GEP NET lesion signal to noise ratio (TCS/TCB) depends on different reconstruction settings for Flash 3D software (Siemens). SRS results of 76 randomly selected patients with confirmed GEP-NET were analyzed. For SPECT studies the data were acquired using standard clinical settings 3-4 h after the injection of 740 MBq 99mTc-[EDDA/HYNIC] octreotate. To obtain final images the OSEM 3D Flash reconstruction with different settings and FBP reconstruction were used. First, the TCS/TCB ratio in voxels was analyzed for different combinations of the number of subsets and the number of iterations of the OSEM 3D Flash reconstruction. Secondly, the same ratio was analyzed for different parameters of the Gaussian filter (with FWHM = 2-4 times greater from the pixel size). Also the influence of scatter correction on the TCS/TCB ratio was investigated. With increasing number of subsets and iterations, the increase of TCS/TCB ratio was observed. With increasing settings of Gauss [FWHM coefficient] filter, the decrease of TCS/TCB ratio was reported. The use of scatter correction slightly decreases the values of this ratio. OSEM algorithm provides a meaningfully better reconstruction of the SRS SPECT study as compared to the FBP technique. A high number of subsets improves image quality (images are smoother). Increasing number of iterations gives a better contrast and the shapes of lesions and organs are sharper. The choice of reconstruction parameters is a compromise between image qualitative appearance and its quantitative accuracy and should not be modified when comparing multiple studies of the same patient.

31 March 2017 in Image Analysis and Stereology
Verified
Journal Article
Open access
PDF file
MNMichał Niedźwiecki
Michał Niedźwiecki
MTMonika Tomaszuk
Monika Tomaszuk
DKDamian Kabat
Damian Kabat
ZLZbigniew Latała
Zbigniew Latała
Krzysztof RzeckiKrzysztof Rzecki
Krzysztof Rzecki
ZTZbisław Tabor
Zbisław Tabor
One of the major procedures for testing the geometrical accuracy of devices used in radiotherapy treatments is the test of the geometrical position of the radiation isocenter. The importance of the test reflects the fact that geometrical position of the radiation isocenter generally affects the tumor targeting. At present the geometric accuracy is assessed with the Winston-Lutz test which checks the position of an image of a ball marker with the respect to the center of the radiation field as projected on a detector plane. Obviously, determination of coordinates of a single marker is not sufficient to fully account for a complicated geometry of a therapeutic device. The purpose of the study was to design a new image analysis tool to better determine the isocenter. The proposed automated procedure for determining isocenter position uses projection data acquired for a special cube phantom. The projection images of a phantom are acquired for various angles of rotation of the gantry. A procedure is proposed to extract some geometric characteristics of a therapeutic device from the projection images.

1 January 2010
Verified
Journal Article
Closed access
MBMonika Buziak-Bereza
Monika Buziak-Bereza
MTMonika Tomaszuk
Monika Tomaszuk
RPRota Pach
Rota Pach
ASAnna Sowa-Staszczak
Anna Sowa-Staszczak
ABAgata Bałdys-Waligórska
Agata Bałdys-Waligórska
AHAlicja B Hubalewska-Dydejczyk
Alicja B Hubalewska-Dydejczyk