Vitaliy Tsirikhov

Vitaliy Tsirikhov

Auto-generated profile, based on publicly available information

Vitaliy Tsirikhov

National medical research center named after academician E. N. Meshalkin

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 July 2020 in Patologiya krovoobrashcheniya i kardiokhirurgiya
Verified
Journal Article
Open access
PDF file
САС. А. Альсов
С. А. Альсов
VTV. Tsirikhov
V. Tsirikhov
ДСД. А. Сирота
Д. А. Сирота
DKD. Khvan
D. Khvan
MLM. Lyashenko
M. Lyashenko
ВЦВ. Р. Цирихов
В. Р. Цирихов
This article presents our experience of using an operating microscope for coronary-artery bypass surgery. The technique, which was developed by the surgeons of Meshalkin National Medical Research Center, involves the use of an operating microscope for performing anastomosis and presents with major difficulties and disadvantages. This paper aims to simplify the procedure of performing anastomosis during coronary-artery bypass surgery using an operating microscope.Received 28 February 2020. Revised 24 March 2020. Accepted 25 March 2020.Funding: The study did not have sponsorship.Conflict of interest: Authors declare no conflict of interest.

28 September 2020 in Journal of Experimental and Clinical Surgery
Verified
Journal Article
Open access
PDF file
MZMaksim Zhulkov
Maksim Zhulkov
AGAlexander Golovin
Alexander Golovin
AGAlexander Grenadyorov
Alexander Grenadyorov
VTVitaliy Tsirikhov
Vitaliy Tsirikhov
ASAzat Sabetov
Azat Sabetov
ЧМЧернявский Александр Михайлович
Чернявский Александр Михайлович
Introduction. Currently, the possibility of effective correction of multiple organ failure and increasing the life expectancy of patients with critical heart failure using the ventricular assist devices (VAD) is absolutely evidenced. The development of alternative analogues of such devices produced within the country has been an urgent problem for many decades. The design of this machine requires the development of a protocol for carrying out complex biomedical studies on the biocompatibility and safety of the new device.The aim of the study was to develop a protocol for testing and conducting comprehensive biomedical biocompatibility studies of a new ventricular assist device in an acute animal experiment.Materials and methods. The study to develop a technique for implanting a left-ventricular assist device (LVAD) in an acute experiment included female mini-pigs, weighed 40-60 kg. In a series of acute experiments, 5 implantations of a disk pump as a LVAD were performed with a maximum observation period equal 6 hours.Results. In the series of acute experiments, an implantation technique was developed and the fundamental possibility of a viscous friction pump application as a ventricular assist device was evidenced. In all experiments (n = 5), the average level of free hemoglobin did not exceed 2.6 mg%, which supports safety of performance of the viscous friction pump regarding blood erythrocytes. None of the experiments recorded episodes of pump shut-off or breakdown.Conclusions. The series of acute experiments on mini-pigs helped reveal a number of anatomical and physiological features of this animal species that significantly complicated implementation of persistent observation. However, the developed experimental LVAD test methodology can be recommended for use in further chronic experiments on large laboratory animals (calves).