Salie Mulat Endalew

Salie Mulat Endalew

Auto-generated profile, based on publicly available information

Salie Mulat Endalew

School of Environmental Health, College of Health and Medical Sciences, Haramaya University, Harar, Ethiopia

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 December 2024 in Multidisciplinary Respiratory Medicine
Verified
Journal Article
Open access
PDF file
LTLiku Muche Temesgen
Liku Muche Temesgen
TATamagnu Sintie Alamirew
Tamagnu Sintie Alamirew
SESalie Mulat Endalew
Salie Mulat Endalew
BMBealemlay Abebe Melake
Bealemlay Abebe Melake
WRWegene Deriba Regassa
Wegene Deriba Regassa
MMMolla Getie Mehari
Molla Getie Mehari
Background: Indoor air pollution, including airborne microorganisms, can cause allergies, respiratory diseases, and immune-toxic diseases. Sneezing generates millions of airborne microbial infections, and ventilation sources alter microbial communities. Few studies exist in developing countries, including Ethiopia, and Harar Town. The aim is to assess microbial indoor air quality and associated factors among private clinics, Harar town, Eastern Ethiopia. Methodology: A cross-sectional study was conducted on 260 private clinic rooms in Harar town, using a systematic random sampling method and passive air sampling. Data was collected using the settle plate method and an observation checklist. Bivariate and multivariate analysis was performed using binary logistic regression, with a P-value of <0.05 considered statistically significant. Result: The minimum and maximum bacterial loads were 3933 CFU/m3 and 92 CFU/m3 respectively. Based on the pollution degree of the European Commission, the Mean bacterial load (904 CFU/m3) was at higher bacterial load. The highest, lowest, and mean fungal loads were 1967 CFU/m3, 9 CFU/m3 and 401 CFU/m3 respectively. Temperature of 28 °C (AOR = 1.23, P = 0.03, and 95% CI = 1.51, 2.02) were significantly associated with bacterial indoor air quality. Relative humidity of treatment rooms (AOR = 1.87, p = 0.02, and 95% CI = 1.21, 3.09) had an association with bacterial loads. The clinic treatment rooms with a recorded temperature 28 °C (AOR = 0.41, p = 0.04, and 95% CI = 0.31, 0.78) were 59% less likely to comply with the fungal standards compared to rooms having a temperature of 25–28 °C. The clinic rooms with a relative humidity of 60% in the treatment rooms. Conclusion: Private clinics in Harar had a moderate fungal load and a higher indoor air bacterial concentration when compared to different indoor air standards. Temperature, humidity, inadequate ventilation and the presence of unsanitary attached toilets are some variables associated with microbial loads.

4 November 2024 in Multidisciplinary Respiratory Medicine
Verified
Journal Article
Open access
PDF file
TATamagnu Sintie Alamirew
Tamagnu Sintie Alamirew
NBNegga Baraki
Negga Baraki
AGAbraham Geremew Gawo
Abraham Geremew Gawo
BMBealemlay Abebe Melake
Bealemlay Abebe Melake
SESalie Mulat Endalew
Salie Mulat Endalew
KBKefelegn Bayu
Kefelegn Bayu
Background: Bacterial indoor air load refers to the level of bacteria within and around dwellings and other structures. Pathogens, bacterial cell fragments, and bacterial organisms’ byproducts can all pose major issues indoors, especially in prison inmate cells. However, there is lack of data on bacterial load and contributing factors in the East Hararghe zone and Harari regional state. The lack of studies on microbiological indoor air quality in prisons with contributing factors will therefore be filled by this investigation. Objectives: The study aimed to assess bacterial indoor air load and contributing factors in prison inmate cells from October 1 to October 30, 2020. Methodology: An institutional cross-sectional study was employed. All of the prisons in the East Hararghe zone and the Harari regional state served as the study’s and source population. 62 prison cells were used in the investigation. Samples were obtained using the passively settling plate technique. The data were evaluated through the use of SPSS statistical software, Excel, and the statistical procedures of ANOVA, correlation, and chi-square test. Results: The maximum and minimum bacterial loads, were recorded at 8:00 am (3027 CFU/m3) and 2:00 pm (1048 (CFU/m3) respectively. The correlation between the temperature and bacterial load was strongly positive (r = 0.680, p = 0.047), and the correlation of the moisture content and bacterial load was strongly negative (r = -0.671, p = 0.039). Conclusion: The levels of bacteria were higher than the guideline (2000 CFU/m3). While the relative humidity of indoor air was negatively correlated with bacterial load, temperature and bacterial load were significantly positively correlated. Harari regional state and East Hararghe zone prison commissions should be alarmed to alleviate these problems. The building standards need to be completely updated to the latest standards.

12 December 2024 in Sustainable Water Resources Management
Verified
Journal Article
Closed access
PDF file
BMBealemlay Abebe Melake
Bealemlay Abebe Melake
TATamagnu Sintie Alamirew
Tamagnu Sintie Alamirew
SESalie Mulat Endalew
Salie Mulat Endalew