Dianne Little

Dianne Little

Auto-generated profile, based on publicly available information

Dianne Little

Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN, USA; Department of Basic Medical Sciences, Purdue University, West Lafayette, IN, USA

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 June 2019 in npj Regenerative Medicine
Verified
Journal Article
Open access
PDF file
TJThomas Lee Jenkins
Thomas Lee Jenkins
DLDianne Little
Dianne Little
Tissue engineering often uses synthetic scaffolds to direct cell responses during engineered tissue development. Since cells reside within specific niches of the extracellular matrix, it is important to understand how the matrix guides cell response and then incorporate this knowledge into scaffold design. The goal of this review is to review elements of cell–matrix interactions that are critical to informing and evaluating cellular response on synthetic scaffolds. Therefore, this review examines fibrous proteins of the extracellular matrix and their effects on cell behavior, followed by a discussion of the cellular responses elicited by fiber diameter, alignment, and scaffold porosity of two dimensional (2D) and three dimensional (3D) synthetic scaffolds. Variations in fiber diameter, alignment, and scaffold porosity guide stem cells toward different lineages. Cells generally exhibit rounded morphology on nanofibers, randomly oriented fibers, and low-porosity scaffolds. Conversely, cells exhibit elongated, spindle-shaped morphology on microfibers, aligned fibers, and high-porosity scaffolds. Cells migrate with higher velocities on nanofibers, aligned fibers, and high-porosity scaffolds but migrate greater distances on microfibers, aligned fibers, and highly porous scaffolds. Incorporating relevant biomimetic factors into synthetic scaffolds destined for specific tissue application could take advantage of and further enhance these responses.

28 August 2023 in Journal of Orthopaedic Research
Verified
Journal Article
Open access
DLDianne Little
Dianne Little
PAPeter Amadio
Peter Amadio
HAHani A. Awad
Hani A. Awad
SCStephanie Cone
Stephanie Cone
NDNathaniel A. Dyment
Nathaniel A. Dyment
LSLouis J Soslowsky
Louis J Soslowsky
Several tendon and ligament animal models were presented at the 2022 Orthopaedic Research Society Tendon Section Conference held at the University of Pennsylvania, May 5 to 7, 2022. A key objective of the breakout sessions at this meeting was to develop guidelines for the field, including for preclinical tendon and ligament animal models. This review summarizes the perspectives of experts for eight surgical small and large animal models of rotator cuff tear, flexor tendon transection, anterior cruciate ligament tear, and Achilles tendon injury using the framework: “Why, Who, What, Where, When, and How” (5W1H). A notable conclusion is that the perfect tendon model does not exist; there is no single gold standard animal model that represents the totality of tendon and ligament disease. Each model has advantages and disadvantages and should be carefully considered in light of the specific research question. There are also circumstances when an animal model is not the best approach. The wide variety of tendon and ligament pathologies necessitates choices between small and large animal models, different anatomic sites, and a range of factors associated with each model during the planning phase. Attendees agreed on some guiding principles including: providing clear justification for the model selected, providing animal model details at publication, encouraging sharing of protocols and expertise, improving training of research personnel, and considering greater collaboration with veterinarians. A clear path for translating from animal models to clinical practice was also considered as a critical next step for accelerating progress in the tendon and ligament field.

1 September 2017 in Tissue Engineering Part A
Verified
Journal Article
Closed access
TJThomas L. Jenkins
Thomas L. Jenkins
SMSean Meehan
Sean Meehan
BPBehnam Pourdeyhimi
Behnam Pourdeyhimi
DLDianne Little
Dianne Little
Various biomaterial technologies are promising for tissue engineering, including electrospinning, but commercial scale-up of throughput is difficult. The goal of the study was to evaluate meltblown fabrics as candidate scaffolds for rotator cuff tendon tissue engineering. Meltblown poly(lactic acid) fabrics were produced with several polymer crystallinities and airflow velocities (500(low), 900(medium) or 1400(high) m3air/hour/m fabric). Fiber diameter, alignment, and baseline bi-directional tensile mechanical properties were evaluated. Attachment and spreading of human adipose-derived stem cells (hASCs) were evaluated over three-days immediately following seeding. After initial screening, the fabric with the greatest Young’s modulus and yield stress was selected for 28-day in vitro culture and for evaluation of tendon-like extracellular matrix production and development of mechanical properties. As expected, airflow velocity of the polymer during meltblowing demonstrated an inverse relationship with fiber diameter. All fabrics exhibited fiber alignment parallel to the direction of collector rotation. All fabrics demonstrated mechanical anisotropy at baseline. Cells attached, proliferated, and spread on all fabrics over the initial three-day culture period. Consistent with the observed loss of integrity of the unseeded biomaterial, hASC-seeded scaffolds demonstrated a significant decrease in Young’s modulus over 28 days of culture. However, dsDNA, sulfated glycosaminoglycan, and collagen content all increased significantly over 28 days. Histology and polarized light microscopy demonstrated collagen deposition and alignment throughout the thickness of the scaffolds. While fiber diameters approximated an order of magnitude greater than those previously reported for electrospun scaffolds intended for tendon tissue engineering they were still within the range of collagen fiber diameters found in healthy tendon. The extent of matrix production and alignment was similar to that previously observed for multilayered electrospun scaffolds. While the Young’s modulus of scaffolds after 28 days of culture was lower than native rotator cuff tendon, it approximated that reported previously following culture of electrospun scaffolds and was on the same order of magnitude as of current FDA-approved patches for rotator cuff augmentation. Together, these data suggest that with minor polymer and parameter modifications meltblown scaffolds could provide an economical, high-throughput production alternative method to electrospinning for use in rotator cuff tendon tissue engineering.

17 September 2021 in Science Advances
Verified
Journal Article
Open access
BEBradley T. Estes
Bradley T. Estes
MEMasataka Enomoto
Masataka Enomoto
FMFranklin T. Moutos
Franklin T. Moutos
MCMegan A. Carson
Megan A. Carson
JTJeffrey M. Toth
Jeffrey M. Toth
BLB. Duncan Lascelles
B. Duncan Lascelles
A 3D woven scaffold seeded with MSCs was used to resurface the canine hip, reducing pain and improving joint function.

1 October 2021 in npj Regenerative Medicine
Verified
Journal Article
Open access
PDF file
PSPaula Sarmiento
Paula Sarmiento
DLDianne Little
Dianne Little
Tendons heal by fibrosis, which hinders function and increases re-injury risk. Yet the biology that leads to degeneration and regeneration of tendons is not completely understood. Improved understanding of the metabolic nuances that cause diverse outcomes in tendinopathies is required to solve these problems. ‘Omics methods are increasingly used to characterize phenotypes in tissues. Multiomics integrates ‘omic datasets to identify coherent relationships and provide insight into differences in molecular and metabolic pathways between anatomic locations, and disease stages. This work reviews the current literature pertaining to multiomics in tendon and the potential of these platforms to improve tendon regeneration. We assessed the literature and identified areas where ‘omics platforms contribute to the field: (1) Tendon biology where their hierarchical complexity and demographic factors are studied. (2) Tendon degeneration and healing, where comparisons across tendon pathologies are analyzed. (3) The in vitro engineered tendon phenotype, where we compare the engineered phenotype to relevant native tissues. (4) Finally, we review regenerative and therapeutic approaches. We identified gaps in current knowledge and opportunities for future study: (1) The need to increase the diversity of human subjects and cell sources. (2) Opportunities to improve understanding of tendon heterogeneity. (3) The need to use these improvements to inform new engineered and regenerative therapeutic approaches. (4) The need to increase understanding of the development of tendon pathology. Together, the expanding use of various ‘omics platforms and data analysis resulting from these platforms could substantially contribute to major advances in the tendon tissue engineering and regenerative medicine field.

1 July 2020 in Journal of Shoulder and Elbow Surgery
Verified
Journal Article
Closed access
ACAbby Chainani
Abby Chainani
AMAndrew Matson
Andrew Matson
MCMasoom Chainani
Masoom Chainani
ACAxel J. Marchand Colon
Axel J. Marchand Colon
ATAlison P. Toth
Alison P. Toth
DLDianne Little
Dianne Little