T. Reuter

T. Reuter

Auto-generated profile, based on publicly available information

T. Reuter

Fzmb GmbH, Geranienweg 7, 99947 Bad Langensalza, Germany

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2015 in Current Directions in Biomedical Engineering
Verified
Journal Article
Open access
PDF file
TRT. Reuter
T. Reuter
IPI. Ponomarev
I. Ponomarev
The biomechanical properties are crucial indicators for the functional characterization of cartilaginous tissue. In this contribution native articular cartilage and three-dimensional scaffold-free cartilage constructs (SFCCs) are characterized by hyperelastic material models (Yeoh, Ogden and Demiray). SFCCs were developed for the therapy of damaged articular cartilage. The normalized error (NE) of fit and experiment is in the range of 0.04 and 0.13. The material model Yeoh with two parameters yields the best fit. The stress-like parameterc 20 is 0.489 MPa for native cartilage, 0.120 MPa and 0.041 MPa for SFCCs produced from mesenchymal stem cells and chondrocytes, respectively. The significance of the fits and the derived parameters are presented and evaluated.

7 January 2013 in Biomedical Engineering / Biomedizinische Technik
Verified
Journal Article
Closed access
PDF file
TRT. Reuter
T. Reuter
SKS. Karl
S. Karl
MHM. Hoffmann
M. Hoffmann
BDB. Dietzek
B. Dietzek

31 January 2012 in Biomedical Engineering / Biomedizinische Technik
Verified
Journal Article
Closed access
PDF file
MHM. Hoffmann
M. Hoffmann
MLM. Lange
M. Lange
FMF. Meuche
F. Meuche
TRT. Reuter
T. Reuter
HPH. Plettenberg
H. Plettenberg
IPI. Ponomarev
I. Ponomarev

7 January 2013 in Biomedical Engineering / Biomedizinische Technik
Verified
Journal Article
Closed access
PDF file
MBM Beck
M Beck
TRT Reuter
T Reuter
SLS Lindner
S Lindner
HRH Richert
H Richert
MHM Hoffmann
M Hoffmann

7 January 2013 in Biomedical Engineering / Biomedizinische Technik
Verified
Journal Article
Closed access
PDF file
IPI. Ponomarev
I. Ponomarev
TRT. Reuter
T. Reuter
AKA. Kammel
A. Kammel
CHC. Hauspurg
C. Hauspurg
AGA. Genzel
A. Genzel
DBD. Barnewitz
D. Barnewitz

1 March 2018
Verified
Dataset
Closed access
RMR. Machts
R. Machts
TRT. Reuter
T. Reuter
PPP.V. Prokop
P.V. Prokop
OSO. Schewtschenko
O. Schewtschenko
MSM. Stubenrauch
M. Stubenrauch
HWH. Witte
H. Witte
Energy harvesting is a feasible method to prolong service life of implanted devices. We present a thermal energy harvesting approach for a ruminal pH-monitoring probe in cattle. Thermoelectric generators utilize the temperature gradient between the probe and the ruminal fluid during water intake. The in vivo experiment yielded a maximum electric power of 32 μW.