Pinyo Taeprasartsit

Pinyo Taeprasartsit

Auto-generated profile, based on publicly available information

Pinyo Taeprasartsit

Department of Computing, Faculty of Science, Silpakorn University, Nakhon Pathom, Thailand

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2014 in Plastic and Reconstructive Surgery
Verified
Journal Article
Closed access
KKKidakorn Kiranantawat
Kidakorn Kiranantawat
NSNgamcherd Sitpahul
Ngamcherd Sitpahul
PTPinyo Taeprasartsit
Pinyo Taeprasartsit
JCJoannis F.R.C.S.(Plast.)(Ed.) Constantinides
Joannis F.R.C.S.(Plast.)(Ed.) Constantinides
AKArthi F.R.C.S.T. Kruavit
Arthi F.R.C.S.T. Kruavit
SNSurawej F.R.C.S.T. Numhom
Surawej F.R.C.S.T. Numhom
Background: Postoperative monitoring of free flap tissue perfusion is vital. Devices available are expensive and complex to operate. Most surgeons rely on direct clinical observation. A monitoring system that is reliable, inexpensive, and easy to operate is needed. Using mobile phone technology, the authors developed and evaluated a new free flap monitoring system: SilpaRamanitor. Methods: Software was developed for Android-operated mobile phones. Forty-two normal subjects were recruited to assess its effectiveness. Varying degrees of pressure were applied around the index finger to produce partial venous occlusion, partial arterial occlusion, complete venous occlusion, and complete arterial occlusion sequentially. Photographs of each subject’s index and middle fingers were taken using the smartphone camera. To detect the abnormal perfusion presented on the index finger, the application was instructed to analyze photographs for color difference, with the unoccluded middle finger serving as the control. Results: The sensitivity, specificity, accuracy, false-negative results, and false-positive results were 94, 98, 95, 6, and 1 percent, respectively. The accuracy of the application in grading occlusion severity was also evaluated. Thirty-nine cases (93 percent) were correctly identified as venous occlusion. The occlusion severity was correctly identified in 33 cases (85 percent). Likewise, for the 40 cases (95 percent) correctly identified as arterial occlusion, the method correctly categorized its severity in 33 cases (83 percent). Conclusions: The authors developed a new, accurate, and reliable diagnostic system for postoperative microsurgery monitoring using a smartphone application. SilpaRamanitor is inexpensive and easy to use, making it applicable in many microsurgical settings. CLINICAL QUESTION/LEVEL OF EVIDENCE: Diagnostic, IV.

27 February 2011 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Closed access
PDF file
KLKongkuo Lu
Kongkuo Lu
PTPinyo Taeprasartsit
Pinyo Taeprasartsit
RBRebecca Bascom
Rebecca Bascom
RMRickhesvar P. M. Mahraj
Rickhesvar P. M. Mahraj
William HigginsWilliam Higgins
William Higgins

1 July 2018
Verified
Conference Paper
Closed access
NPNanthipath Pholberdee
Nanthipath Pholberdee
CPChanok Pathompatai
Chanok Pathompatai
PTPinyo Taeprasartsit
Pinyo Taeprasartsit
Chronic wound segmentation is an essential task for evaluating wound and its recovery progress. A physician usually measures a wound area to choose proper treatment according to wound conditions. However, precise measurement needs accurate image-region segmentation. With the advent of deep learning for semantic image segmentation, accuracy of region segmentation is dramatically higher than traditional methods. Unfortunately, semantic segmentation in prior work did not produce satisfactory outputs in wound image segmentation, even with a large training dataset. This work, therefore, rethinks about the challenge and aims at not only improving segmentation accuracy, but also studying the impact of wound tissue types and color on accuracy. Since an end-to-end approach of semantic segmentation in prior work performed relatively poorly, the proposed method employs both image processing and deep learning techniques. The experiments indicated that slough was the most challenging tissue to be segmented. Also, properly increasing color variety of wound images significantly improved segmentation performance. The accuracy of the proposed method was 72%, 40% and 53% in terms of intersection over union for granulation, necrosis, and slough wound tissue types, respectively. The proposed method outperformed a prior end-to-end approach, even though this method employed particularly simpler neural network models and much smaller number of training images.

1 January 2019
Verified
Conference Paper
Closed access
BSBoonnatee Sakboonyara
Boonnatee Sakboonyara
PTPinyo Taeprasartsit
Pinyo Taeprasartsit
Nowadays, 3D computed tomography (CT) data is commonly employed to diagnose liver cancer or to examine liver condition. This work proposes a method that can quickly find a location of the biggest CT slice of the liver. We also extend this method to demonstrate that it can work as an efficient algorithm for liver segmentation. The proposed method is based on a U-Net, fully convolutional neural network, to roughly segment the liver and employs a mean-shift clustering algorithm to enhance liver localization accuracy. This addition of mean-shift clustering on histogram data after rough segmentation by U-Net prevents oversegmentation of the liver and significantly improves the accuracy of a method solely relying on a U-Net. A novel image-enhancement technique based on statistical thresholding is also introduced to further increase accuracy. This hybrid method processed each slice in 0.35 seconds on average (75 seconds per image) and its median accuracy measured in Dice similarity index in 5-fold cross-validation was 95%.

8 March 2007
Verified
Conference Paper
Closed access
PTPinyo Taeprasartsit
Pinyo Taeprasartsit
WHWilliam E. Higgins
William E. Higgins
Bronchoscopic biopsy of the central-chest lymph nodes is vital in the staging of lung cancer. Three-dimensional multi-detector CT (MDCT) images provide vivid anatomical detail for planning bronchoscopy. Unfortunately, many lymph nodes are situated close to the aorta, and an inadvertent needle biopsy could puncture the aorta, causing serious harm. As an eventual aid for more complete planning of lymph-node biopsy, it is important to define the aorta. This paper proposes a method for extracting the aorta from a 3D MDCT chest image. The method has two main phases: (1) Off-line Model Construction, which provides a set of training cases for fitting new images, and (2) On-Line Aorta Construction, which is used for new incoming 3D MDCT images. Off-Line Model Construction is done once using several representative human MDCT images and consists of the following steps: construct a likelihood image, select control points of the medial axis of the aortic arch, and recompute the control points to obtain a constant-interval medial-axis model. On-Line Aorta Construction consists of the following operations: construct a likelihood image, perform global fitting of the precomputed models to the current case's likelihood image to find the best fitting model, perform local fitting to adjust the medial axis to local data variations, and employ a region recovery method to arrive at the complete constructed 3D aorta. The region recovery method consists of two steps: model-based and region-growing steps. This region growing method can recover regions outside the model coverage and non-circular tube structures. In our experiments, we used three models and achieved satisfactory results on twelve of thirteen test cases.

4 March 2010
Verified
Conference Paper
Closed access
PDF file
PTPinyo Taeprasartsit
Pinyo Taeprasartsit
WHWilliam E. Higgins
William E. Higgins
Accurate definition of the aorta and pulmonary artery from three-dimensional (3D) multi-detector CT (MDCT) images is important for pulmonary applications. This work presents robust methods for defining the aorta and pulmonary artery in the central chest. The methods work on both contrast enhanced and no-contrast 3D MDCT image data. The automatic methods use a common approach employing model fitting and selection and adaptive refinement. During the occasional event that more precise vascular extraction is desired or the method fails, we also have an alternate semi-automatic fail-safe method. The semi-automatic method extracts the vasculature by extending the medial axes into a user-guided direction. A ground-truth study over a series of 40 human 3D MDCT images demonstrates the efficacy, accuracy, robustness, and efficiency of the methods.