3 March 2020 in IEEE Transactions on Power Electronics
Analogizing the sub-synchronous resonance (SSR) phenomenon of the series-compensated grid-connected system based on synchronous generator, the virtual synchronous generator (VSG) also has the low-frequency oscillation problem owing to the impedance interaction between VSG and series-compensated network. Stability of the series-compensated grid-connected system controlled by VSG is analyzed by the impedance-based Nyquist stability criterion. Due to the inductive impedance of VSG, VSG is easy to couple with the series-compensated network in the low-frequency areas, which can lead to the SSR. With the increase of the series compensation level, the stability of VSG becomes worse and the induced oscillation frequency becomes higher. Therefore, a mod-ulation signal feedforward active damping control strategy with time delay compensation is proposed to suppress this SSR, which directly feeds the active-damping control signal to the PWM modulator for reshaping the output impedance of VSG from the inductance to the resistance-inductance. Moreover, a value range of virtual resistance is given with considering the influence on the regular operation of VSG. Finally, simulation and experimental results verify the correctness of the SSR analysis and the feasibility of the proposed active-damping control strategy.
13 February 2019 in IEEE Journal of Emerging and Selected Topics in Power Electronics
27 May 2020 in IEEE Transactions on Industrial Electronics
In the current power system, the conversion between dc and ac is widely existing and the dc-side harmonic problem is prominent. To suppress the second-harmonic current at the dc side of a single-stage single-phase inverter, a dc hybrid active power filter (DC-HAPF) structure is presented, which composes of a bidirectional dc-dc circuit-based active power filter (APF) and a CL passive filter. In this article, the CL passive filter is used to mitigate the high-frequency harmonics and the APF is applied to compensate the low-frequency harmonic current. Meanwhile, the influence of the filter parameters on the harmonic suppression is analyzed based on the average switching model. In addition, for the control of the DC-HAPF, a nonlinear unified controller via feedback linearization is proposed, where the voltage and current dual-loop control is converted to a single-loop control of energy. By analyzing the control system stability and DC-HAPF's performance, appropriate control parameters are selected. To verify the feasibility of the proposed topology and control strategy, a 500-W single-stage single-phase inverter with the DC-HAPF is built and a good performance of the dc-side harmonic suppression has been achieved.
11 May 2018 in IEEE Transactions on Power Electronics
To manage the power quality of high-speed V/v traction system, a multilevel railway power conditioner (MRPC) is researched. According to the structure and equivalent models of MRPC, basically the MRPC is a symmetrical system, and its four clusters can be divided into two cluster-groups. According to the ac equivalent mathematical models of cluster-groups, it can be considered as the relationships in the αβ frame, but not completely symmetrical, so the positive- and negative-sequence dq models for cluster-groups can be derived. As the fluctuation and randomness of the locomotive loads, a sliding mode control system based on the exponential reaching law in the dq frame is explored to control the cluster ac currents, which can improve the dynamic performance and keep a good tolerance against parameter mismatches. Finally, an experimental prototype is developed, and the results show the feasibility and the robustness of the system.
20 December 2018 in IEEE Transactions on Power Electronics
Due to the train load stochastic jumps, negative sequence currents (NSCs) are unpredictably brought into power grid, which may attack the power system and damage vital devices. To enhance the compensation capacities and improve the power quality, a hybrid scheme is studied in consideration of load stochastic jumps, composed of railway power conditioner, thyristor switched capacitor, and thyristor switched reactor. First, the load discrete jump model and its compensation principle of V/v railway traction system are analyzed to design the hybrid compensators and the capacities. Then, based on the attack-defense game theory, a two-level optimized hybrid controller is proposed to keep the power system affirmative for any train load attacks. In the hybrid system, defender 1 is a discrete strategy that can be early executed by finite logic to minimize the power demands, and defender 2 is a continuous strategy that can be lately controlled by optimal control to minimize NSCs. By this dynamic game, an optimized hybrid compensation can be realized. Finally, simulations and experiments are completed to prove the compensation abilities of the hybrid system and the effectiveness of the hybrid control strategy.