Karsten Heia

Karsten Heia

Auto-generated profile, based on publicly available information

Karsten Heia

Department of Seafood Industry from the Norwegian Institute of Food, Fisheries and Aquaculture Research, Nofima AS, Tromsø, Norway

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2022 in Talanta
Verified
Journal Article
Open access
TLTiril Aurora Lintvedt
Tiril Aurora Lintvedt
PAPetter Vejle Andersen
Petter Vejle Andersen
NANils Kristian Afseth
Nils Kristian Afseth
KHKarsten Heia
Karsten Heia
SLStein-Kato Lindberg
Stein-Kato Lindberg
JWJens Petter Wold
Jens Petter Wold
Raman spectroscopy was compared with near infrared (NIR) hyperspectral imaging for determination of fat composition (%EPA + DHA) in salmon fillets at short exposure times. Fillets were measured in movement for both methods. Salmon were acquired from several different farming locations in Norway with different feeding regimes, representing a realistic variation of salmon in the market. For Raman, we investigated three manual scanning strategies; i) line scan of loin, ii) line scan of belly and iii) sinusoidal scan of belly at exposure times of 2s and 4s. NIR images were acquired while the fillets moved on a conveyor belt at 40 cm/s, which corresponds to an acquisition time of 1s for a 40 cm long fillet. For NIR images, three different regions of interest (ROI) were investigated including the i) whole fillet, ii) belly segment, and iii) loin segment. For both Raman and NIR measurements, we investigated an untrimmed and trimmed version of the fillets, both relevant for industrial in-line evaluation. For the trimmed fillets, a fat rich deposition layer in the belly was removed. The %EPA + DHA models were validated by cross validation (N = 51) and using an independent test set (N = 20) which was acquired in a different season. Both Raman and NIR showed promising results and high performances in the cross validation, with R2CV = 0.96 for Raman at 2s exposure and R2CV = 0.97 for NIR. High performances were obtained also for the test set, but while Raman had low and stable biases for the test set, the biases were high and varied for the NIR measurements. Analysis of variance on the squared test set residuals showed that performance for Raman measurements were significantly higher than NIR at 1% significance level (p = 0.000013) when slope-and-bias errors were not corrected, but not significant when residuals were slope-and-bias corrected (p = 0.28). This indicated that NIR was more sensitive to matrix effects. For Raman, signal-to-noise ratio was the main limitation and there were indications that Raman was close to a critical sample exposure time at the 2s signal accumulation.

1 November 2020 in LWT
Verified
Journal Article
Open access
KAKathryn E. Anderssen
Kathryn E. Anderssen
SSSvein Kristian Stormo
Svein Kristian Stormo
TSTorstein Skåra
Torstein Skåra
MSMartin Skjelvareid
Martin Skjelvareid
KHKarsten Heia
Karsten Heia

13 June 2011 in Journal of Agricultural and Food Chemistry
Verified
Journal Article
Closed access
SOSilje Ottestad
Silje Ottestad
OSOddvin Sørheim
Oddvin Sørheim
KHKarsten Heia
Karsten Heia
JSJosefine Skaret
Josefine Skaret
Jens WoldJens Wold
Jens Wold

4 February 2023 in LWT
Verified
Journal Article
Open access
Samuel OrtegaSamuel Ortega
Samuel Ortega
SLStein-Kato Lindberg
Stein-Kato Lindberg
SOStein Harris Olsen
Stein Harris Olsen
KAKathryn E. Anderssen
Kathryn E. Anderssen
KHKarsten Heia
Karsten Heia

16 April 2025 in IEEE Transactions on Multimedia
Verified
Journal Article
Open access
Samuel OrtegaSamuel Ortega
Samuel Ortega
TATatiana N. Ageeva
Tatiana N. Ageeva
SKSilje Kristoffersen
Silje Kristoffersen
KHKarsten Heia
Karsten Heia
HNHeidi A. Nilsen
Heidi A. Nilsen
Fish quality and shelf life can be evaluated using various assessment methods, such as sensory analysis, biochemical tests, microbiological evaluations, and physicochemical analyses. However, these methods are invasive and time-consuming, driving interest in technologies capable of estimating shelf life through non-invasive procedures. This study investigates the potential of hyperspectral imaging as a non-invasive technology for predicting the shelf life of Atlantic cod. A storage experiment was conducted that included both gutted fish with heads (GFWH) and fillets, with sensory evaluation and biochemical measurements employed to determine shelf life. Subsequently, hyperspectral images of the fish samples were captured under industrial production conditions, and the spectral data were analyzed using different regression algorithms. The majority of the regression techniques utilized in this research successfully predicted shelf life for both fillets and GFWH, achieving a root mean square error (RMSE) lower than one day. While most regression models exhibited comparable performance in predicting the shelf life of fillets, deep learningbased models demonstrated superior performance for GFWH. These results suggest that hyperspectral imaging technology has significant potential as a non-invasive tool for estimating the shelf life of Atlantic cod, thereby enabling effective quality-based sorting, reducing food waste, and enhancing sustainability in the seafood supply chain.

23 December 2022 in Applied Food Research
Verified
Journal Article
Open access
SOSamuel Ortega
Samuel Ortega
RORagni Ofstad
Ragni Ofstad
SSShaheen Syed
Shaheen Syed
MKMathias Kranz
Mathias Kranz
KHKarsten Heia
Karsten Heia
KAKathryn E. Anderssen
Kathryn E. Anderssen