Svenn Anton Halvorsen

Svenn Anton Halvorsen

Auto-generated profile, based on publicly available information

Svenn Anton Halvorsen

Teknova AS

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 August 2019 in Metallurgical and Materials Transactions B
Verified
Journal Article
Open access
PDF file
EHEgil Vålandsmyr Herland
Egil Vålandsmyr Herland
MSManuel Sparta
Manuel Sparta
SHSvenn Anton Halvorsen
Svenn Anton Halvorsen
A review of two-dimensional (2D) analytical models of skin and proximity effects in large industrial furnaces with three electrodes arranged in an equilateral triangle is given. The models cover three different cases: one electrode only, three electrodes where two are approximated by line currents, and induced shell currents where all electrodes are approximated by line currents. The first two models show how the skin and proximity effects depend on electrode material properties and size, and the distance between the electrodes. The third model shows how the strength of the induced shell currents will depend on electrode position and furnace size. These models are compared to numerical studies including distributed electrodes and shell currents. The analytical models are accurate when induced shell currents can be disregarded. However, strong shell currents may have a significant impact on the current distribution within the electrodes. This electrode-shell proximity effect competes with the electrode-electrode proximity effect. Finally, the 2D models have been compared with three-dimensional (3D) case studies of large industrial furnaces. In 3D, the shell currents are significantly smaller than what are predicted by the 2D models, but they are sufficiently strong to cause a significant correction of the electrode current density.

1 January 2018 in Journal of the Southern African Institute of Mining and Metallurgy
Verified
Journal Article
Open access
PDF file
EHE.V. Herland
E.V. Herland
MSM. Sparta
M. Sparta
SHS.A. Halvorsen
S.A. Halvorsen
Many large furnaces used for production of ferroalloys are operated using three-phase alternating current. In such furnaces, there are significant skin and proximity effects caused by induction effects in, and between, the electrodes. Moreover, there may be high currents induced in the furnace steel shell. This causes additional proximity effects between the currents in the electrodes and alloy, and the induced currents in the lining and shell. A numerical study of such effects in realistic 3D geometries of ferromanganese and ferrosilicon furnaces is presented. The models are used to estimate the induced currents in the steel shell as well as accurate alternating current distributions in the material layers within the furnace. Also, the active and reactive power densities within the furnace are studied. The results show that there are strong skin and proximity effects in the conductive material layers within the furnace. Both the electrode proximity effects and the proximity effects caused by the steel shell are computed. The latter can be significant, and should be included when high accuracy is required.


8 June 2023 in Metallurgical and Materials Transactions B
Verified
Journal Article
Open access
PDF file
SHSvenn Anton Halvorsen
Svenn Anton Halvorsen
EHEgil Vålandsmyr Herland
Egil Vålandsmyr Herland
MSManuel Sparta
Manuel Sparta
VRVetle Kjær Risinggård
Vetle Kjær Risinggård
A simple and generic model for the heat distribution in electrodes for primary metal production has been investigated. The equations have been analyzed focusing on understanding the scale-up of electrodes under both direct current (DC) and alternating current (AC) conditions. The analysis provides a theoretical foundation for Westly’s empirical scale-up rule. For graphite and small carbon electrodes, the current-carrying capacity is limited by the ohmic heating, which controls the lateral heat flux and the temperature at the electrode periphery. For these electrodes, the current capacity is higher for DC than for AC. For large carbon or Søderberg electrodes, the electrode current must be limited to avoid large thermal stresses and subsequent breakages, especially in connection with shutdowns or considerable current fluctuations. Thermally, the current capacity is then limited by the maximum temperature difference between the center and the periphery. For this case, AC electrodes can carry more current than DC.

1 November 2017 in International Communications in Heat and Mass Transfer
Verified
Journal Article
Closed access
LRLindon Roberts
Lindon Roberts
ENEllen Nordgård-Hansen
Ellen Nordgård-Hansen
ØMØyvind Mikkelsen
Øyvind Mikkelsen
SHSvenn Anton Halvorsen
Svenn Anton Halvorsen
RGRobert A. Van Gorder
Robert A. Van Gorder

6 September 2011 in Computational Geosciences
Verified
Journal Article
Closed access
PDF file
SHSvenn Anton Halvorsen
Svenn Anton Halvorsen
AMAre Mjaavatten
Are Mjaavatten
RARobert Aasheim
Robert Aasheim