Zachary M. Smith

Zachary M. Smith

Auto-generated profile, based on publicly available information

Zachary M. Smith

Eaton-Peabody Laboratory, Massachusetts Eye and Ear Infirmary, Boston, MA, USA

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 March 2002 in Nature
Verified
Journal Article
Closed access
PDF file
ZSZachary M. Smith
Zachary M. Smith
BDBertrand Delgutte
Bertrand Delgutte
AOAndrew J. Oxenham
Andrew J. Oxenham

30 January 2014 in Journal of the Association for Research in Otolaryngology
Verified
Journal Article
Closed access
PDF file
CLChristopher J. Long
Christopher J. Long
THTimothy A. Holden
Timothy A. Holden
GMGary H. McClelland
Gary H. McClelland
WPWendy S. Parkinson
Wendy S. Parkinson
CSClough Shelton
Clough Shelton
ZSZachary M. Smith
Zachary M. Smith

25 February 2009 in Journal of Neuroscience
Verified
Journal Article
Open access
PDF file
PNPaul C. Nelson
Paul C. Nelson
ZSZachary M. Smith
Zachary M. Smith
EYEric D. Young
Eric D. Young
An organism's ability to detect and discriminate sensory inputs depends on the recent stimulus history. For example, perceptual detection thresholds for a brief tone can be elevated by as much as 50 dB when following a masking stimulus. Previous work suggests that such forward masking is not a direct result of peripheral neural adaptation; the central pathway apparently modifies the representation in a way that further attenuates the input's response to short probe signals. Here, we show that much of this transformation is complete by the level of the inferior colliculus (IC). Single-neuron extracellular responses were recorded in the central nucleus of the awake marmoset IC. The threshold for a 20 ms probe tone presented at best frequency was determined for various masker-probe delays, over a range of masker sound pressure levels (SPLs) and frequencies. The most striking aspect of the data was the increased potency of forward maskers as their SPL was increased, despite the fact that the excitatory response to the masker was often saturating or nonmonotonic over the same range of levels. This led to probe thresholds at high masker levels that were almost always higher than those observed in the auditory nerve. Probe threshold shifts were not usually caused by a persistent excitatory response to the masker; instead we propose a wide-dynamic-range inhibitory mechanism locked to sound offset as an explanation for several key aspects of the data. These findings further delineate the role of subcortical auditory processing in the generation of a context-dependent representation of ongoing acoustic scenes.

1 December 2017 in The Journal of the Acoustical Society of America
Verified
Journal Article
Open access
NCNaomi B. H. Croghan
Naomi B. H. Croghan
SDSara I. Duran
Sara I. Duran
ZSZachary M. Smith
Zachary M. Smith
This study reconsiders the number of effective channels in contemporary cochlear implants. Subjects listened to matrix sentences with a competing talker using their clinical map (up to 22 electrodes) and reduced-channel maps using 12, 8, and 4 electrodes. Spectro-temporal modulation thresholds and reading span were measured to explore intersubject variability. Results show that speech understanding significantly improved with increasing active electrodes up to 22, particularly for subjects with better spectro-temporal resolution. These findings suggest some listeners may be able to utilize the full electrode array and may not be limited to eight channels of information as indicated in previous studies.

1 October 2003 in The Journal of the Acoustical Society of America
Verified
Journal Article
Closed access
PDF file
LLLeonid M. Litvak
Leonid M. Litvak
ZSZachary M. Smith
Zachary M. Smith
BDBertrand Delgutte
Bertrand Delgutte
DEDonald K. Eddington
Donald K. Eddington
Rubinstein et al. [Hear. Res. 127, 108–118 (1999)] suggested that the neural representation of the waveforms of electric stimuli might be improved by introducing an ongoing, high-rate, desynchronizing pulse train (DPT). A DPT may desynchronize neural responses to electric stimulation in a manner similar to spontaneous activity in a healthy ear. To test this hypothesis, responses of auditory-nerve fibers (ANFs) to 10-min-long electric pulse trains (5 kpps) were recorded from acutely deafened, anesthetized cats. Stimuli were delivered via an intracochlear electrode, and their amplitude was chosen to elicit a response in most ANFs. Responses to pulse trains showed pronounced adaptation during the first 1–2 min, followed by either a sustained response or cessation of spike discharges for the remainder of the stimulus. The adapted discharge rates showed a broad distribution across the ANF population like spontaneous activity. However, a higher proportion of fibers (46%) responded to the DPT at rates below 5 spikes/s than for spontaneous activity, and 12% of the fibers responded at higher rates than any spontaneously active fiber. Interspike interval histograms of sustained responses for some fibers had Poisson-like (exponential) shapes, resembling spontaneous activity, while others exhibited preferred intervals and, occasionally, bursting. Simultaneous recordings from pairs of fibers revealed no evidence of correlated activity, suggesting that the DPT does desynchronize the auditory nerve activity. Overall, these results suggest that responses to an ongoing DPT resemble spontaneous activity in a normal ear for a substantial fraction of the ANFs.

20 June 2007 in The Journal of Neuroscience
Verified
Journal Article
Open access
PDF file
ZSZachary M. Smith
Zachary M. Smith
BDBertrand Delgutte
Bertrand Delgutte
Bilateral cochlear implantation attempts to increase performance over a monaural prosthesis by harnessing the binaural processing of the auditory system. Although many bilaterally implanted human subjects discriminate interaural time differences (ITDs), a major cue for sound localization and signal detection in noise, their performance is typically poorer than that of normal-hearing listeners. We developed an animal model of bilateral cochlear implantation to study neural ITD sensitivity for trains of electric current pulses delivered via bilaterally implanted intracochlear electrodes. We found that a majority of single units in the inferior colliculus of acutely deafened, anesthetized cats are sensitive to ITD and that electric ITD tuning is as sharp as found for acoustic stimulation with broadband noise in normal-hearing animals. However, the sharpness and shape of ITD tuning often depended strongly on stimulus intensity; some neurons had dynamic ranges of ITD sensitivity as low as 1 dB. We also found that neural ITD sensitivity was best at pulse rates below 100 Hz and decreased with increasing pulse rate. This rate limitation parallels behavioral ITD discrimination in bilaterally implanted individuals. The sharp neural ITD sensitivity found with electric stimulation at the appropriate intensity is encouraging for the prospect of restoring the functional benefits of binaural hearing in bilaterally implanted human subjects and suggests that neural plasticity resulting from previous deafness and deprivation of binaural experience may play a role in the poor ITD discrimination with current bilateral implants.