15 January 2007 in Journal of Applied Physics
Ionomeric polymer transducers consist of an ion-conducting membrane sandwiched between two metal electrodes. Application of a low voltage (2% strain) due to the transport of ionic species within the polymer matrix. A computational model of transport and electromechanical transduction is developed for ionomeric polymer transducers. The transport model is based upon a coupled chemoelectrical multifield formulation and computes the spatiotemporal volumetric charge density profile to an applied potential at the boundaries. The current induced in the polymer is computed using the isothermal transient ionic current associated with surface charge accumulation at the electrodes induced by nonzero volumetric charge density within the polymer. The stress induced in the polymer is assumed to be a summation of linear and quadratic functions of the volumetric charge density. Euler-Bernoulli beam mechanics are used to compute the bending deflection of the transducer to an applied potential. The diffusion coefficient and permittivity of the polymer is identified from the measured current density to a step change in the applied potential. A comparison between the measured data and the predicted response demonstrates that this model accurately predicts the current discharge due to the applied potential at voltages over the range of 50–500mV. Furthermore, the measured strain response is accurately predicted by determining the two parameters of the mechanics model that relates volumetric charge density to induced stress. The coupled model with parameters identified from the step response analysis is used to predict the harmonic response of the current and the bending strain. Comparisons between measured data and simulations illustrate that the coupled transport-mechanics model accurately predicts the magnitude and trends associated with the current response and strain output. Excellent agreement is obtained at excitation periods above approximately 1s while good agreement is obtained at longer excitation periods. The transport model highlights the importance of the asymmetry that develops at large applied potentials and long excitation periods in the volumetric charge density due to the fixed anionic species in the polymer.
1 March 2001 in Journal of Intelligent Material Systems and Structures
Ionic polymers are a class of active material that exhibit large bending deflections under the application of an electric field. Previous research has demonstrated that the response of an actuator in air is characterized by a large initial deflection and a relaxation to a steady-state value. The time constant of the relaxation is of the order 5–20 s and the overshoot of the step response is typically greater than 100%. These aspects of the step response limit the actuation bandwidth of the material. In this work we explore the use of feedback control techniques to eliminate the large overshoot and reduce the settling time of cantilevered ionic polymer actuators. Control models are developed from measurements of the actuator response to a step change in the applied voltage. The models demonstrate that the dynamics relevant to the control problem can be separated into a low-frequency (< 5 Hz) range in which the response is characterized by a series of time constants, and a high-frequency range (> 10 Hz) characterized by the resonance of the actuator. For shorter polymers the resonance is sufficiently high that it can be ignored in the control design, but the resonant response becomes significant as the length of the polymer increases. Control simulations based on Linear Quadratic Regulator (LQR) theory demonstrate that feedback control eliminates the overshoot in the step response and decreases the settling time by a factor of 10. Control of the actuator oscillation is accomplished by using an LQR weighting matrix that includes the states associated with the actuator resonance, whereas a state weighting matrix that does not include these terms results in a compensator that includes a notch at the actuator resonance. Experimental results on the shorter polymer demonstrate that the overshoot in the step response is eliminated and the settling time is reduced from 12–16 s to 1–2 s, thus verifying the ability of feedback control to shape the step response of the actuator. Experimental results on the longer polymer demonstrate that incorporating the resonance terms in the LQR weighting matrix is the superior control design method. Designs that included a notch in the compensator were unstable for very low gains because of variations in the actuator resonance due to changes in surface hydration. Designs that included phase lead in the compensator produced superior closed-loop performance and resulted in reductions in overshoot and settling time of the order 6–10 s.
6 January 2010 in Lab on a Chip
Physically-encapsulated droplet interface bilayers are formed by confining aqueous droplets encased in lipid monolayers within connected compartments of a solid substrate. Each droplet resides within an individual compartment and is positioned on a fixed electrode built into the solid substrate. Full encapsulation of the network is achieved with a solid cap that inserts into the substrate to form a closed volume. Encapsulated networks provide increased portability over unencapsulated networks by limiting droplet movement and through the integration of fixed electrodes into the supporting fixture. The formation of encapsulated droplet interface bilayers constructed from diphytanoyl phosphocoline (DPhPC) phospholipids is confirmed with electrical impedance spectroscopy, and cyclic voltammetry is used to measure the effect of alamethicin channels incorporated into the resulting lipid bilayers. The durability of the networks is quantified using a mechanical shaker to oscillate the bilayer in a direction transverse to the plane of the membrane and the results show that single droplet interface bilayers can withstand 1–10g of acceleration prior to bilayer failure. Observed failure modes include both droplet separation and bilayer rupturing, where the geometry of the supporting substrate and the presence of integrated electrodes are key contributors. Physically-encapsulated DIBs can be shaken, moved, and inverted without bilayer failure, enabling the creation of a new class of lab-on-chip devices.
6 May 2003 in Smart Materials and Structures
18 April 2011 in Soft Matter
A gel-supported lipid bilayer formed at the base of an artificial hair is used as the transduction element in an artificial, membrane-based hair cell sensor inspired by the structure and function of mammalian hair cells. This paper describes the initial fabrication and characterization of a bioderived, soft-material alternative to previous artificial hair cells that used the transduction properties of synthetic materials for flow and touch sensing. Under an applied air flow, the artificial hair structure vibrates, triggering a picoamp-level electrical current across the lipid bilayer. Experimental analysis of this mechanoelectrical transduction process supports the hypothesis that the current is produced by a time-varying change in the capacitance of the membrane caused by the vibration of the hair. Specifically, frequency analysis of both the motion of the hair and the measured current show that both phenomena occur at similar frequencies (0.1–1.0 kHz), which suggests that changes in capacitance occur as a result of membrane bending during excitation. In this paper, the bilayer-based hair cell sensor is experimentally characterized to understand the effects of transmembrane potential, the applied air flow, and the dimensions of the hair.
14 May 2008 in Sensors and Actuators B: Chemical