Ricardo Coimbra Brioso

Ricardo Coimbra Brioso

Auto-generated profile, based on publicly available information

Ricardo Coimbra Brioso

Dipartimento di Elettronica Informazione e Bioingegneria Politecnico di Milano Milan Italy

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 February 2023 in Cancers
Verified
Journal Article
Open access
PDF file
DDDamiano Dei
Damiano Dei
NLNicola Lambri
Nicola Lambri
SSSara Stefanini
Sara Stefanini
VVVeronica Vernier
Veronica Vernier
RBRicardo Coimbra Brioso
Ricardo Coimbra Brioso
PMPietro Mancosu
Pietro Mancosu
Background: The total marrow and lymph node irradiation (TMLI) target includes the bones, spleen, and lymph node chains, with the latter being the most challenging structures to contour. We evaluated the impact of introducing internal contour guidelines to reduce the inter- and intraobserver lymph node delineation variability in TMLI treatments. Methods: A total of 10 patients were randomly selected from our database of 104 TMLI patients so as to evaluate the guidelines’ efficacy. The lymph node clinical target volume (CTV_LN) was recontoured according to the guidelines (CTV_LN_GL_RO1) and compared to the historical guidelines (CTV_LN_Old). Both topological (i.e., Dice similarity coefficient (DSC)) and dosimetric (i.e., V95 (the volume receiving 95% of the prescription dose) metrics were calculated for all paired contours. Results: The mean DSCs were 0.82 ± 0.09, 0.97 ± 0.01, and 0.98 ± 0.02, respectively, for CTV_LN_Old vs. CTV_LN_GL_RO1, and between the inter- and intraobserver contours following the guidelines. Correspondingly, the mean CTV_LN-V95 dose differences were 4.8 ± 4.7%, 0.03 ± 0.5%, and 0.1 ± 0.1%. Conclusions: The guidelines reduced the CTV_LN contour variability. The high target coverage agreement revealed that historical CTV-to-planning-target-volume margins were safe, even if a relatively low DSC was observed.

1 June 2023
Verified
Conference Paper
Closed access
RBRicardo Coimbra Brioso
Ricardo Coimbra Brioso
JPJoão Pedrosa
João Pedrosa
AMAna Maria Maria Rodrigues de Sousa Faria Mendonça
Ana Maria Maria Rodrigues de Sousa Faria Mendonça
ACAurelio Campilho
Aurelio Campilho
The importance of X-Ray imaging analysis is paramount for health care institutions since it is the main imaging modality for patient diagnosis, and deep learning can be used to aid clinicians in image diagnosis or structure segmentation. In recent years, several articles demonstrate the capability that deep learning models have in classifying and segmenting chest x-ray images if trained in an annotated dataset. Unfortunately, for segmentation tasks, only a few relatively small datasets have annotations, which poses a problem for the training of robust deep learning strategies. In this work, a semi-supervised approach is developed which consists of using available information regarding other anatomical structures to guide the segmentation when the groundtruth segmentation for a given structure is not available. This semi-supervised is compared with a fully- supervised approach for the tasks of lung segmentation and for multi-structure segmentation (lungs, heart and clavicles) in chest x-ray images. The semi-supervised lung predictions are evaluated visually and show relevant improvements, therefore this approach could be used to improve performance in external datasets with missing groundtruth. The multi-structure predictions show an improvement in mean absolute and Hausdorff distances when compared to a fully supervised approach and visual analysis of the segmentations shows that false positive predictions are removed. In conclusion, the developed method results in a new strategy that can help solve the problem of missing annotations and increase the quality of predictions in new datasets.

18 April 2024 in Medical Physics
Verified
Journal Article
Open access
NLNicola Lambri
Nicola Lambri
GLGiorgio Longari
Giorgio Longari
DLDaniele Loiacono
Daniele Loiacono
RBRicardo Coimbra Brioso
Ricardo Coimbra Brioso
LCLeonardo Crespi
Leonardo Crespi
PMPietro Mancosu
Pietro Mancosu
Background: Total marrow (lymphoid) irradiation (TMI/TMLI) is a radiotherapy treatment used to selectively target the bone marrow and lymph nodes in conditioning regimens for allogeneic hematopoietic stem cell transplantation. A complex field geometry is needed to cover the large planning target volume (PTV) of TMI/TMLI with volumetric modulated arc therapy (VMAT). Five isocenters and ten overlapping fields are needed for the upper body, while, for patients with large anatomical conformation, two specific isocenters are placed on the arms. The creation of a field geometry is clinically challenging and is performed by a medical physicist (MP) specialized in TMI/TMLI.Purpose: To develop convolutional neural networks (CNNs) for automatically generating the field geometry of TMI/TMLI.Methods: The dataset comprised 117 patients treated with TMI/TMLI between 2011 and 2023 at our Institute. The CNN input image consisted of three channels, obtained by projecting along the sagittal plane: (1) average CT pixel intensity within the PTV; (2) PTV mask; (3) brain, lungs, liver, bowel, and bladder masks. This “averaged” frontal view combined the information analyzed by the MP when setting the field geometry in the treatment planning system (TPS). Two CNNs were trained to predict the isocenters coordinates and jaws apertures for patients with (CNN‐1) and without (CNN‐2) isocenters on the arms. Local optimization methods were used to refine the models output based on the anatomy of the patient. Model evaluation was performed on a test set of 15 patients in two ways: (1) by computing the root mean squared error (RMSE) between the CNN output and ground truth; (2) with a qualitative assessment of manual and generated field geometries—scale: 1 = not adequate, 4 = adequate—carried out in blind mode by three MPs with different expertise in TMI/TMLI. The Wilcoxon signed‐rank test was used to evaluate the independence of the given scores between manual and generated configurations (p < 0.05 significant).Results: The average and standard deviation values of RMSE for CNN‐1 and CNN‐2 before/after local optimization were 15 ± 2/13 ± 3 mm and 16 ± 2/18 ± 4 mm, respectively. The CNNs were integrated into a planning automation software for TMI/TMLI such that the MPs could analyze in detail the proposed field geometries directly in the TPS. The selection of the CNN model to create the field geometry was based on the PTV width to approximate the decision process of an experienced MP and provide a single option of field configuration. We found no significant differences between the manual and generated field geometries for any MP, with median values of 4 versus 4 (p = 0.92), 3 versus 3 (p = 0.78), 4 versus 3 (p = 0.48), respectively. Starting from October 2023, the generated field geometry has been introduced in our clinical practice for prospective patients.Conclusions: The generated field geometries were clinically acceptable and adequate, even for an MP with high level of expertise in TMI/TMLI. Incorporating the knowledge of the MPs into the development cycle was crucial for optimizing the models, especially in this scenario with limited data.

6 April 2023 in Current Oncology
Verified
Journal Article
Open access
PDF file
NLNicola Lambri
Nicola Lambri
SAsimone leopoldo antonetti
simone leopoldo antonetti
DDDamiano Dei
Damiano Dei
LBLuisa Bellu
Luisa Bellu
SBStefania Bramanti
Stefania Bramanti
PMPietro Mancosu
Pietro Mancosu
Total marrow (lymph node) irradiation (TMI/TMLI) delivery requires more time than standard radiotherapy treatments. The patient’s extremities, through the joints, can experience large movements. The reproducibility of TMI/TMLI patients’ extremities was evaluated to find the best positioning and reduce unwanted movements. Eighty TMI/TMLI patients were selected (2013–2022). During treatment, a cone-beam computed tomography (CBCT) was performed for each isocenter to reposition the patient. CBCT-CT pairs were evaluated considering: (i) online vector shift (OVS) that matched the two series; (ii) residual vector shift (RVS) to reposition the patient’s extremities; (iii) qualitative agreement (range 1–5). Patients were subdivided into (i) arms either leaning on the frame or above the body; (ii) with or without a personal cushion for foot positioning. The Mann-Whitney test was considered (p < 0.05 significant). Six-hundred-twenty-nine CBCTs were analyzed. The median OVS was 4.0 mm, with only 1.6% of cases ranked < 3, and 24% of RVS > 10 mm. Arms leaning on the frame had significantly smaller RVS than above the body (median: 8.0 mm/6.0 mm, p < 0.05). Using a personal cushion for the feet significantly improved the RVS than without cushions (median: 8.5 mm/1.8 mm, p < 0.01). The role and experience of the radiotherapy team are fundamental to optimizing the TMI/TMLI patient setup.

13 October 2024
Verified
Book Chapter
Closed access
PDF file
RBRicardo Coimbra Brioso
Ricardo Coimbra Brioso
DDDamiano Dei
Damiano Dei
NLNicola Lambri
Nicola Lambri
PMPietro Mancosu
Pietro Mancosu
MSMarta Scorsetti
Marta Scorsetti
DLDaniele Loiacono
Daniele Loiacono

9 February 2024 in arXiv
Verified
Preprint
Open access
PDF file
RBRicardo Coimbra Brioso
Ricardo Coimbra Brioso
DDDamiano Dei
Damiano Dei
NLNicola Lambri
Nicola Lambri
DLDaniele Loiacono
Daniele Loiacono
PMPietro Mancosu
Pietro Mancosu
MSMarta Scorsetti
Marta Scorsetti
In order to optimize the radiotherapy delivery for cancer treatment, especially when dealing with complex treatments such as Total Marrow and Lymph Node Irradiation (TMLI), the accurate contouring of the Planning Target Volume (PTV) is crucial. Unfortunately, relying on manual contouring for such treatments is time-consuming and prone to errors. In this paper, we investigate the application of Deep Learning (DL) to automate the segmentation of the PTV in TMLI treatment, building upon previous work that introduced a solution to this problem based on a 2D U-Net model. We extend the previous research (i) by employing the nnU-Net framework to develop both 2D and 3D U-Net models and (ii) by evaluating the trained models on the PTV with the exclusion of bones, which consist mainly of lymp-nodes and represent the most challenging region of the target volume to segment. Our result show that the introduction of nnU-NET framework led to statistically significant improvement in the segmentation performance. In addition, the analysis on the PTV after the exclusion of bones showed that the models are quite robust also on the most challenging areas of the target volume. Overall, our study is a significant step forward in the application of DL in a complex radiotherapy treatment such as TMLI, offering a viable and scalable solution to increase the number of patients who can benefit from this treatment.