Jung Hyun Yoon

Jung Hyun Yoon

Auto-generated profile, based on publicly available information

Jung Hyun Yoon

Department of Radiology, Severance Hospital, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul, Korea

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2011 in Radiology
Verified
Journal Article
Closed access
JKJin Young Kwak
Jin Young Kwak
KHKyunghwa Han
Kyunghwa Han
JYJung Hyun Yoon
Jung Hyun Yoon
HMHee Jung Moon
Hee Jung Moon
ESEun Ju Son
Eun Ju Son
EKEun-Kyung Kim
Eun-Kyung Kim
To develop a practical thyroid imaging reporting and data system (TIRADS) with which to categorize thyroid nodules and stratify their malignant risk. The institutional review board approved this retrospective study, and the requirement to obtain informed consent for the review of images and records was waived. From May to December 2008, ultrasonographically (US)-guided fine-needle aspiration biopsy (FNAB) was performed in 3674 focal thyroid nodules in 3414 consecutive patients. The study included the 1658 thyroid nodules (≥1 cm in maximum diameter at US) in 1638 patients (1373 women, 265 men) for which pathologic diagnosis or follow-up findings were available. Univariate and multivariate analyses with generalized estimating equations were performed to investigate the relationship between suspicious US features and thyroid cancer. A score for each significant factor was assigned and multiplied by the β coefficient obtained for each significant factor from multivariate logistic regression analysis. Scores for each significant factor were then added, resulting in an equation that fitted the probability of malignancy in thyroid nodules. The authors evaluated the fitted probability by using a regression equation; the risk of malignancy was determined according to the number of suspicious US features. The following US features showed a significant association with malignancy: solid component, hypoechogenicity, marked hypoechogenicity, microlobulated or irregular margins, microcalcifications, and taller-than-wide shape. As the number of suspicious US features increased, the fitted probability and risk of malignancy also increased. Positive predictive values according to the number of suspicious US features were significantly different (P < .001). Risk stratification of thyroid malignancy by using the number of suspicious US features allows for a practical and convenient TIRADS.

1 January 2021 in Korean Journal of Radiology
Verified
Journal Article
Open access
PDF file
EHEun Ju Ha
Eun Ju Ha
SCSae Rom Chung
Sae Rom Chung
DNDong Gyu Na
Dong Gyu Na
HAHye Shin Ahn
Hye Shin Ahn
JCJin Chung
Jin Chung
MCMiyoung Choi
Miyoung Choi
Ha EJ, et al. Korean J Radiol. 2021 Dec;22(12):2094-2123. https://doi.org/10.3348/kjr.2021.0713

1 March 2016 in Radiology
Verified
Journal Article
Closed access
JYJung Hyun Yoon
Jung Hyun Yoon
HLHye Sun Lee
Hye Sun Lee
EKEun-Kyung Kim
Eun-Kyung Kim
HMHee Jung Moon
Hee Jung Moon
JKJin Young Kwak
Jin Young Kwak
To compare malignancy risk stratification of thyroid nodules with the 2014 American Thyroid Association (ATA) management guidelines and the Thyroid Imaging Reporting and Data System (TIRADS). This retrospective study was approved by the institutional review board. The requirement to obtain informed consent was waived. From November 2013 to July 2014, 1293 thyroid nodules in 1241 patients (mean age, 50.8 years ± 13.5) were included in this study. All nodules measured at least 10 mm. Solidity, hypoechogenicity or marked hypoechogenicity, microlobulated to irregular margin, microcalcifications or mixed calcifications, and nonparallel shape were considered suspicious features at ultrasonography (US). A TIRADS category and the US pattern as determined with ATA guidelines were assigned to each nodule. The correlation between the TIRADS category or ATA pattern and the malignancy rate was evaluated with the Spearman rank test. Of the 1293 thyroid nodules, 1059 (81.9%) were benign and 234 (18.1%) were malignant. Forty-four of the 1293 nodules (3.4%) did not meet the criteria for the ATA patterns and were classified as "not specified." The malignancy rates of TIRADS category 3, 4a, 4b, 4c, and 5 nodules were 1.9% (six of 316 nodules), 4.2% (17 of 408 nodules), 12.9% (33 of 256 nodules), 49.8% (130 of 261 nodules), and 92.3% (48 of 52 nodules), respectively, with significant differences between categories (P < .001). Malignancy rates of nodules with very low, low, intermediate, and high suspicion for malignancy with the ATA guidelines and not specified patterns were 2.7% (11 of 407 nodules), 3.1% (10 of 323 nodules), 16.7% (39 of 233 nodules), 58.0% (166 of 286 nodules), and 18.2% (eight of 44 nodules), respectively, with significant differences between patterns (P < .001). There was high correlation between classification with TIRADS (r = 1.000, P < .001) and ATA guidelines (r = 0.900, P = 0.037), without statistically significant differences (P = .873). Both TIRADS and the ATA guidelines provide effective malignancy risk stratification for thyroid nodules. Nodules that do not meet the criteria for a specific pattern with the ATA guidelines have a relatively high risk of malignancy (18.2%).

1 March 2012 in Radiology
Verified
Journal Article
Closed access
HMHee Jung Moon
Hee Jung Moon
JSJi Min Sung
Ji Min Sung
EKEun-Kyung Kim
Eun-Kyung Kim
JYJung Hyun Yoon
Jung Hyun Yoon
JYJi Hyun Youk
Ji Hyun Youk
JKJin Young Kwak
Jin Young Kwak
To evaluate the diagnostic performance of gray-scale ultrasonography (US) and elastography in differentiating benign and malignant thyroid nodules. This was an institutional review board-approved retrospective study with waiver of informed consent. A total of 703 solid thyroid nodules in 676 patients (mean age, 49.7 years; range, 18-79 years) were included; there were 556 women (mean age, 49.5 years; range, 20-74 years) and 120 men (mean age, 50.7 years; range, 18-79 years). Nodules with marked hypoechogenicity, poorly defined margins, microcalcifications, and a taller-than-wide shape were classified as suspicious at grayscale US. Findings at elastography were classified according to the Rago criteria and the Asteria criteria. The diagnostic performances of gray-scale US and elastography were compared. For comparison between the diagnostic performances of gray-scale US and the combination of gray-scale US and elastography, three sets of criteria were assigned: criteria set 1, nodules with any suspicious grayscale US feature were assessed as suspicious; criteria set 2, Rago criteria were added as suspicious features to criteria set 1; and criteria set 3, Asteria criteria were added as suspicious features to criteria set 1. The diagnostic performances of gray-scale US, elastography with Rago criteria, and elastography with Asteria criteria, and odds ratios (ORs) with 95% confidence intervals for predicting thyroid malignancy were compared using generalized estimating equation analysis. Of 703 nodules, 217 were malignant and 486 were benign. Sensitivity, negative predictive value (NPV), and OR of gray-scale US for the 703 nodules were 91.7%, 94.7%, and 22.1, respectively, and these values were higher than the 15.7% and 65.4% sensitivity, 71.7% and 79.1% NPV, and 3.7 and 2.6 ORs found for elastography with Rago and Asteria criteria, respectively. Specificity, positive predictive value, and accuracy for criteria set 1 were significantly higher than those for criteria sets 2 and 3 for most of the nodule subgroups that were considered. Elastography alone, as well as the combination of elastography and gray-scale US, showed inferior performance in the differentiation of malignant and benign thyroid nodules compared with gray-scale US features; elastography was not a useful tool in recommending fine-needle aspiration biopsy.

1 June 2023 in Radiology
Verified
Journal Article
Closed access
JYJung Hyun Yoon
Jung Hyun Yoon
FSFredrik Strand
Fredrik Strand
PBPascal A.T. Baltzer
Pascal A.T. Baltzer
ECEmily F Conant
Emily F Conant
FGFiona J. Gilbert
Fiona J. Gilbert
RMRitse M. Mann
Ritse M. Mann
Background There is considerable interest in the potential use of artificial intelligence (AI) systems in mammographic screening. However, it is essential to critically evaluate the performance of AI before it can become a modality used for independent mammographic interpretation. Purpose To evaluate the reported standalone performances of AI for interpretation of digital mammography and digital breast tomosynthesis (DBT). Materials and Methods A systematic search was conducted in PubMed, Google Scholar, Embase (Ovid), and Web of Science databases for studies published from January 2017 to June 2022. Sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) values were reviewed. Study quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 and Comparative (QUADAS-2 and QUADAS-C, respectively). A random effects meta-analysis and meta-regression analysis were performed for overall studies and for different study types (reader studies vs historic cohort studies) and imaging techniques (digital mammography vs DBT). Results In total, 16 studies that include 1 108 328 examinations in 497 091 women were analyzed (six reader studies, seven historic cohort studies on digital mammography, and four studies on DBT). Pooled AUCs were significantly higher for standalone AI than radiologists in the six reader studies on digital mammography (0.87 vs 0.81, P = .002), but not for historic cohort studies (0.89 vs 0.96, P = .152). Four studies on DBT showed significantly higher AUCs in AI compared with radiologists (0.90 vs 0.79, P < .001). Higher sensitivity and lower specificity were seen for standalone AI compared with radiologists. Conclusion Standalone AI for screening digital mammography performed as well as or better than radiologists. Compared with digital mammography, there is an insufficient number of studies to assess the performance of AI systems in the interpretation of DBT screening examinations. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Scaranelo in this issue.

1 March 2011 in American Journal of Roentgenology
Verified
Journal Article
Closed access
JYJung Hyun Yoon
Jung Hyun Yoon
MKMyung Hyun Kim
Myung Hyun Kim
EKEun-Kyung Kim
Eun-Kyung Kim
HMHee Jung Moon
Hee Jung Moon
JKJin Young Kwak
Jin Young Kwak
MKMin Jung Kim
Min Jung Kim
OBJECTIVE. The purpose of this article is to evaluate the interobserver variability of elastography on real-time ultrasound and how it influences the agreement of final assessment on ultrasound. SUBJECTS AND METHODS. From April to May 2009, 65 breast lesions of 53 patients (mean age, 42.6 years; range, 18–72 years) who underwent ultrasound-guided core biopsy were included in this study. Ultrasound and elastography images of the lesion subjected to biopsy were obtained and prospectively analyzed by three radiologists with individual real-time image scanning prior to biopsy. Each radiologist recorded final ultrasound BI-RADS assessments using ultrasound and combined ultrasound and elastography and the fat-to-lesion ratio and elasticity score. The histopathologic results obtained from ultrasound-guided core biopsy or excision were used as the reference standard. Diagnostic performances and interobserver agreement were analyzed. RESULTS. Of the 65 lesions, 43 (66.2%) were benign, and 22 (33.8%) were malignant. Specificity (20.2–33.3%), positive predictive value (38.7–45.1%), and accuracy (46.7–55.4%) were significantly improved in combined ultrasound and elastography (p < 0.001). Area under the curve (AUC) values for all three performers did not show significant differences in ultrasound (AUC, 0.959) and combined ultrasound and elastography (AUC, 0.957) (p = 0.92). Interobserver agreement was not improved with combined ultrasound and elastography (κ = 0.25) in comparison to ultrasound only (κ = 0.37). Interobserver agreement of real-time elastography was fair in both fat-to-lesion ratio (intraclass correlation coefficient score, 0.25) and elasticity score (κ = 0.28). Moderate agreement (κ = 0.46) was seen with static elastography. CONCLUSION. Elastography improves the specificity, positive predictive value, and accuracy of ultrasound. However, significant interobserver variability exists, with real-time elastographic performance showing fair agreement.