Han Pyo Lee

Han Pyo Lee

Auto-generated profile, based on publicly available information

Han Pyo Lee

Hongik University

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 July 2023 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
YLYiyan Li
Yiyan Li
LSLidong Song
Lidong Song
YHYi Hu
Yi Hu
HLHanpyo Lee
Hanpyo Lee
DWDi Wu
Di Wu
NLNing Lu
Ning Lu
This paper introduces a Generative Adversarial Nets (GAN) based, Load Profile Inpainting Network (Load-PIN) for restoring missing load data segments and estimating the baseline for a demand response event. The inputs are time series load data before and after the inpainting period together with explanatory variables (e.g., weather data). We propose a Generator structure consisting of a coarse network and a fine-tuning network. The coarse network provides an initial estimation of the data segment in the inpainting period. The fine-tuning network consists of self-attention blocks and gated convolution layers for adjusting the initial estimations. Loss functions are specially designed for the fine-tuning and the discriminator networks to enhance both the point-to-point accuracy and realisticness of the results. We test the Load-PIN on three real-world data sets for two applications: patching missing data and deriving baselines of conservation voltage reduction (CVR) events. We benchmark the performance of Load-PIN with five existing deep-learning methods. Our simulation results show that, compared with the state-of-the-art methods, Load-PIN can handle varying-length missing data events and achieve 15%-30% accuracy improvement.

4 August 2023 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
YHYi Hu
Yi Hu
YLYiyan Li
Yiyan Li
LSLidong Song
Lidong Song
HLHan Pyo Lee
Han Pyo Lee
PRP. J. Rehm
P. J. Rehm
NLNing Lu
Ning Lu
This paper presents a deep-learning framework, Multi-load Generative Adversarial Network (MultiLoad-GAN), for generating a group of synthetic load profiles (SLPs) simultaneously. The main contribution of MultiLoad-GAN is the capture of spatial-temporal correlations among a group of loads that are served by the same distribution transformer. This enables the generation of a large amount of correlated SLPs required for microgrid and distribution system studies. The novelty and uniqueness of the MultiLoad-GAN framework are three-fold. First, to the best of our knowledge, this is the first method for generating a group of load profiles bearing realistic spatial-temporal correlations simultaneously. Second, two complementary realisticness metrics for evaluating generated load profiles are developed: computing statistics based on domain knowledge and comparing high-level features via a deep-learning classifier. Third, to tackle data scarcity, a novel iterative data augmentation mechanism is developed to generate training samples for enhancing the training of both the classifier and the MultiLoad-GAN model. Simulation results show that MultiLoad-GAN can generate more realistic load profiles than existing approaches, especially in group level characteristics. With little finetuning, MultiLoad-GAN can be readily extended to generate a group of load or PV profiles for a feeder or a service area.

31 May 2024 in Applied Energy
Verified
Journal Article
Closed access
HLHan Pyo Lee
Han Pyo Lee
YLYiyan Li
Yiyan Li
LSLidong Song
Lidong Song
DWDi Wu
Di Wu
NLNing Lu
Ning Lu


17 May 2024 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
HLHan Pyo Lee
Han Pyo Lee
PRPj Rehm
Pj Rehm
MMMatthew Makdad
Matthew Makdad
EMEdmond Miller
Edmond Miller
NLNing Lu
Ning Lu
This paper presents a novel power-band-based data segmentation (PBDS) method to enhance the identification of meter phase and meter-transformer pairing. Meters that share the same transformer or are on the same phase typically exhibit strongly correlated voltage profiles. However, under high power consumption, there can be significant voltage drops along the line connecting a customer to the distribution transformer. These voltage drops significantly decrease the correlations among meters on the same phase or supplied by the same transformer, resulting in high misidentification rates. To address this issue, we propose using power bands to select highly correlated voltage segments for computing correlations, rather than relying solely on correlations computed from the entire voltage waveforms. The algorithm's performance is assessed by conducting tests using data gathered from 13 utility feeders. To ensure the credibility of the identification results, utility engineers conduct field verification for all 13 feeders. The verification results unequivocally demonstrate that the proposed algorithm surpasses existing methods in both accuracy and robustness.

14 September 2023 in IEEE Access
Verified
Journal Article
Open access
HLHan Pyo Lee
Han Pyo Lee
KDKeith Dsouza
Keith Dsouza
KCKe Chen
Ke Chen
NLNing Lu
Ning Lu
MBMesut E. Baran
Mesut E. Baran
The growing integration of distributed energy resources into distribution systems poses challenges to voltage regulation. Dynamic VAR Compensators (DVCs) are a new generation of power electronics-based Volt/VAR compensation devices designed to address voltage issues in distribution systems with a high penetration of renewable generation resources. Currently, the IEEE Std. 1547 based Volt/VAR Curve (VV-C) is widely used as the local control scheme for controlling a DVC. However, the effectiveness of this scheme is not well documented, and there is limited literature on alternative control and placement schemes that can maximize the effective use of a DVC. In this paper, we propose an optimal dispatch and control mechanism to enhance the conventional Volt/VAR Curve (VV-C) based localized DVC control. First, we establish a multi-objective optimization framework to identify the optimal dispatch strategy and suitable placement for the DVC. Next, we introduce two supervisory control strategies to determine the appropriate instances for adjusting the VV-C when the operating condition changes. The outlined scheme comprises two primary stages: time segmentation and VV-C fitting.Within this framework, each time segment aims to produce optimized Q-V trajectories. The proposed method is tested on a modified IEEE 123-bus test system using OpenDSS for a wide range of operating scenarios, including sunny and cloudy days. Simulation results demonstrate that the proposed scheme effectively reduces voltage variations compared to the standard VV-C specified in IEEE Std. 1547.