Ryuji Nakamura

Ryuji Nakamura

Auto-generated profile, based on publicly available information

Ryuji Nakamura

Department of Anesthesiology and Critical Care, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 1994 in International journal of pancreatology
Verified
Journal Article
Closed access
PDF file
RNRyuji Nakamura
Ryuji Nakamura
RMRicardo Machado
Ricardo Machado
KAKatsumi Amikura
Katsumi Amikura
BRBoris Ruehner
Boris Ruehner
CFCharles F. Frey
Charles F. Frey

15 February 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
HMHiroki Matsubara
Hiroki Matsubara
HHHiroki Hirano
Hiroki Hirano
HHHarutoyo Hirano
Harutoyo Hirano
ZSZu Soh
Zu Soh
RNRyuji Nakamura
Ryuji Nakamura
TTToshio Tsuji
Toshio Tsuji
In clinical practice, subjective pain evaluations, e.g., the visual analogue scale and the numeric rating scale, are generally employed, but these are limited in terms of their ability to detect inaccurate reports, and are unsuitable for use in anesthetized patients or those with dementia. We focused on the peripheral sympathetic nerve activity that responds to pain, and propose a method for evaluating pain sensation, including intensity, sharpness, and dullness, using the arterial stiffness index. In the experiment, electrocardiogram, blood pressure, and photoplethysmograms were obtained, and an arterial viscoelastic model was applied to estimate arterial stiffness. The relationships among the stiffness index, self-reported pain sensation, and electrocutaneous stimuli were examined and modelled. The relationship between the stiffness index and pain sensation could be modelled using a sigmoid function with high determination coefficients, whereR2 ≥ 0.88,p < 0.01 for intensity,R2 ≥ 0.89,p < 0.01 for sharpness, andR2 ≥ 0.84,p < 0.01 for dullness when the stimuli could appropriately evoke dull pain.

20 July 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
TTToshio Tsuji
Toshio Tsuji
TNTomonori Nobukawa
Tomonori Nobukawa
AMAkihisa Mito
Akihisa Mito
HHHarutoyo Hirano
Harutoyo Hirano
ZSZu Soh
Zu Soh
MYMasao Yoshizumi
Masao Yoshizumi
In this paper, we propose a novel method for predicting acute clinical deterioration triggered by hypotension, ventricular fibrillation, and an undiagnosed multiple disease condition using biological signals, such as heart rate, RR interval, and blood pressure. Efforts trying to predict such acute clinical deterioration events have received much attention from researchers lately, but most of them are targeted to a single symptom. The distinctive feature of the proposed method is that the occurrence of the event is manifested as a probability by applying a recurrent probabilistic neural network, which is embedded with a hidden Markov model and a Gaussian mixture model. Additionally, its machine learning scheme allows it to learn from the sample data and apply it to a wide range of symptoms. The performance of the proposed method was tested using a dataset provided by Physionet and the University of Tokyo Hospital. The results show that the proposed method has a prediction accuracy of 92.5% for patients with acute hypotension and can predict the occurrence of ventricular fibrillation 5 min before it occurs with an accuracy of 82.5%. In addition, a multiple disease condition can be predicted 7 min before they occur, with an accuracy of over 90%.

24 February 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
TTToshio Tsuji
Toshio Tsuji
FAFumiya Arikuni
Fumiya Arikuni
TSTakafumi Sasaoka
Takafumi Sasaoka
SSShin Suyama
Shin Suyama
TATakashi Akiyoshi
Takashi Akiyoshi
SYShigeto Yamawaki
Shigeto Yamawaki
Brain activity associated with pain perception has been revealed by numerous PET and fMRI studies over the past few decades. These findings helped to establish the concept of the pain matrix, which is the distributed brain networks that demonstrate pain-specific cortical activities. We previously found that peripheral arterial stiffness $${\beta }_{\text{art}}$$ β art responds to pain intensity, which is estimated from electrocardiography, continuous sphygmomanometer, and photo-plethysmography. However, it remains unclear whether and to what extent $${\beta }_{\text{art}}$$ β art aligns with pain matrix brain activity. In this fMRI study, 22 participants received different intensities of pain stimuli. We identified brain regions in which the blood oxygen level-dependent signal covaried with $${\beta }_{\text{art}}$$ β art using parametric modulation analysis. Among the identified brain regions, the lateral and medial prefrontal cortex and ventral and dorsal anterior cingulate cortex were consistent with the pain matrix. We found moderate correlations between the average activities in these regions and $${\beta }_{\text{art}}$$ β art (r = 0.47, p < 0.001). $${\beta }_{\text{art}}$$ β art was also significantly correlated with self-reported pain intensity (r = 0.44, p < 0.001) and applied pain intensity (r = 0.43, p < 0.001). Our results indicate that $${\beta }_{\text{art}}$$ β art is positively correlated with pain-related brain activity and subjective pain intensity. This study may thus represent a basis for adopting peripheral arterial stiffness as an objective pain evaluation metric.

22 February 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
HTHiroshi Tanaka
Hiroshi Tanaka
AMAkihisa Mito
Akihisa Mito
HHHarutoyo Hirano
Harutoyo Hirano
ZSZu Soh
Zu Soh
RNRyuji Nakamura
Ryuji Nakamura
TTToshio Tsuji
Toshio Tsuji
This paper proposes an algorithm for estimating the arterial viscosity using cuff pressures and pulse waves measured by an automatic oscillometric sphygmomanometer. A change in the arterial viscosity during the enclosed-zone flow-mediated dilation test is calculated as an index for evaluating the vascular endothelial function %η. In all, 43 individuals participated in this study. After the index %η was calculated, the accuracy of the index %η in distinguishing healthy subjects and subjects at a high risk of arteriosclerosis was tested via a receiving operating characteristic (ROC) analysis. The calculated %η for the healthy participants and those at a high risk of arteriosclerosis was 13.4 ± 55.1% and −32.7 ± 34.0% (mean ± S.D.), respectively. The area under the ROC curve was 0.77. Thus, it was concluded that the proposed method can be used to evaluate the vascular endothelial function.

25 November 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
NHNaoki Hagiyama
Naoki Hagiyama
HHHarutoyo Hirano
Harutoyo Hirano
AMAkihisa Mito
Akihisa Mito
ZSZu Soh
Zu Soh
EFEtsunori Fujita
Etsunori Fujita
TTToshio Tsuji
Toshio Tsuji
This paper proposes a novel unconstrained monitoring system that measures heart and respiratory rates and evaluates autonomic nervous activity based on heart rate variability. The proposed system measures the aortic pulse waves (APWs) of a patient via an APW sensor that comprises a single microphone integrated into a mattress. Vital signs (i.e., heart rate, respiratory rate) and autonomic nervous activity were analyzed using the measured APWs. In an experiment with supine and seated participants, vital signs calculated by the proposed system were compared with vital signs measured with commercial devices, and we obtained the correlations of r > 0.8 for the heart rates, r > 0.7 for the respiratory rates, and r > 0.8 for the heart rate variability indices. These results indicate that the proposed system can produce accurate vital sign measurements. In addition, we performed the experiment of image stimulus presentation and explored the relationships between the self-reported psychological states evoked by the stimulus and the measured vital signs. The results indicated that vital signs reflect psychological states. In conclusion, the proposed system demonstrated its ability to monitor health conditions by actions as simple as sitting or lying on the APW sensor.